Loading...
HomeMy WebLinkAboutTED4002765.1Q co ti m X E 0 N I I 0 V c.0 N N rn rn 0 a; E a� a 0 c� 0 0 I DO 0 i z ry w w z CD z w i 00 cD i 0 r Lo 0 a_ 17 ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS R I M =,�a5-66' 394.86 FRAME AND LADDER OR STEPS OFFSET. SEE PLAN SHEET. I H z 00 0 392.45 RISER OVERFLOW ELEV=,3��' ORIFICE NO. 2 STANDARD GALVANIZED ORIFICE 0=1 3/4" E L. --,-a1-�6- STEEL LADDER/STEPS 391.60 P .. PIPE SUPPORTS 311x.090 GAGE BOLTED OR IMBEDDED 2" IN WALL AT MAXIMUM 3' SPACING. MINIMUM ONE SUPPORT. 36" INLET 389.20 IE 0 cli O z N N � (714 0 0 p 12" FLOW RESTRICTOR MANHOLE (CB #1) SCALE: 1 "=2' QED -fit o-��6t 12' OUTLET 389.15 I E89-36' 8" DIA. CLEANOUT SHEAR GATE RESTRICTOR PLATE ORIFICE 0=1 /2" EL.=387.30 PRECAST CONCRETE VAULT WITH 2 - 3'x 3' HINGED STEEL PLATE COVERS. DIMENSIONS 5-0" x 9'-0" x 7'-2" UTILITY VAULT CO. 4484-LA OR EQUAL --- THE BY-PASS ASSEMBLY SHALL BE INCLUDED AS PART -OF THE DETECTOR DOUBLE CHECK VALVE ASSEMBLY. 4" FL. x P.E. D.I. PIPE WITH COLLAR 18" FROM P.E. 3'-4" LONG DETAIL SHEET A PORTION OF SOUTHWEST 1/4 OF SOUTHWEST 1/4, SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. CITY OF RENTION, KING COUNTY, WASHINGTON NOTES: 1. PIPE SIZES & SLOPES: SEE PLANS. 2. OUTLET CAPACITY NOT LESS THAN COMBINED INLETS 3. METAL PARTS: A) GALVANIZED STEEL PIPE, HAVE ASPHALT TREATMENT I 4. FRAME & LADDER OR STEPS OFFSET SO: A) CLEANOUT GATE IS VISIBLE FROM TOP B) CLIMBDOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C) FRAME IS CLEAR OF CURB IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". NOTES: 1. METAL PIPE: A. CSP 3x1 CORRUGATION, MIN 12 GAUGE THICKNESS B. 36" CMP, 2 2/3"x1/2" CORRUGATED STEEL PIPE, MIN THK 0.079" 2. METAL PIPE SHALL BE CORROSION RESISTANT BY ONE THE FOLLOWING: A. GALVANIZED STEEL PIPE, HAVE ASPHALT TREATMENT I OR BETTER 3. MINIMUM COVER FROM TOP OF PIPE TO TOP OF SUBGRADE IS 24 INCHES. CB # 1. TYPE II-54" W/ROUND SOLID LOCKING LID AND FLOW RESTRICTOR PER DETAIL BELOW RIM=SEE DETAIL THIS SHT IE=SEE DETAIL THIS SHT 93 LF CMP DETENTION PIPE FINISH GRADE CB #2. TYPE-54" W/ROUND SOLID LOCKING LID RIM- - ;"b9-394.34 IE=�e'(36) 389.14 fNl IE= �4-86 12") 390.84 (S) IE=393.00(6") 36" SD FROM DETENTION PIPE TYPE II-54" FLOW CONTROL MANHOLE (CB # 1) SCALE: 1 "=2 9" 6" MIN 1" 7" 1" io a a 77/7 a a a d � ASPHALT EXTRUDED CONCRETE CURB DETAIL NOT TO SCALE 11-1/2' x 17-1/2' CONCRETE METER BOX WITH 3/16' STEEL DIAM❑ND PLATE COVER EQUAL TO FOG TITE METER SEAL CO. 1D METER BOX. w IN UNIMPR❑VED RIGHT OF WAY w INSTALL METER BOX AT PROPERTY LINE, Li Li SIDEWALK a WATER METER TO BE SUPPLIED BY THE CITY TYPE 'K' SOFT COPPER TUBING 12' MIN 3' MIN COVER STORAGE 2" AIR VENT 2 12" SD 22-1i2 °7ER L 0RD C❑PPERSETTERLIVE REQUIRED VOLUME-1106 CF TYP. VH 172-15W (F❑R 5/8' x 3/4" METERL,,,,.,-2 LF 36" CMP REQUIRED VOLUME=1,106x1.41=1,560 CF Q � r-VH CAST IR❑N ❑R 174-15W (F❑R 1' METER) 389.20 PROVIDED VOLUME=1,620 CF o 389.14 DUCTILE IR❑N LO❑P D❑WNPADL❑CK B❑TH INLET AND OUTLET WITH PACK J❑INT WITH GRIPPER.OUTFLOW WINGS ❑N KEY VALVE SINGLE CHECK VALVEEL ,3$9-36- 0 EL _,i� � WATERMAIN ❑F WATER E ❑N ❑UTLET. SLACK IN CALL PACK-J❑INT FITTINGS SHALL BE WITH GRIPPER: DEAD STORAGE LINE T❑ MEREQUIRED VOLUME=998 CFC❑RP❑RATI❑N ST❑P, F❑R IF SERVICE LINE TO HOUSE IS TO BE EL=387.00 PROVIDED VOLUME=1,010 CF `V EL=387.00 THREAD (CC). PACK J❑INT (3/4' F1000) INSTALLED IN THE FUTURE INSTALL (1' F1000) FORD C14-33 OR 44 FIDT x C❑MPRESSI❑N COUPLING DETENTION PIPE DETAIL 22-1120 3/4" OR 1" GALVANIZED PLUG L NOT TO SCALE FOR SERVICE FROM EXISTING STEEL 3/4" & 1" WATER SERVICE ASBESTOS CEMENT OR PVC WATER MAINS INSTALL DOUBLE STRAP SERVICE CLAMP 4 2" FIRE DEPARTMENT DOUBLE "x 2 1 / EQUAL TO MUELLER CO, CONNECTION FOR STAND PIPE WITH ADOPTED r�� BREAKABLE CAST IRON HOSE CAPS. CITY OF RENTON ONE EACH SIDE EQUAL TO GRINNEL FIG. K�m); Standard plans 682 WITH HOSE CAPS FIG. 1333. Isr DATE: 12/I5/91 4" PIPE FL.x FL. 4" SWING TYPE GRAVITY OPERATED DATE REVISION BY DWG. NAME: BR41 SP PAGE: B106 2'-0" LONG CHECK VALVE, FL. EQUAL TO I I JAPPR MUELLER CO. A-2600-6 WITH BALL DRIP VALVE AT BOTTOM " 34 9'-0" INSTALL EPDXY NON -SHRINK GROUT (TYP.) 4" PIPE, FL.x FL. 3'0" LONG FLUSH WITH /4TO 2DC " " FOR 3 VA, USE FOGTITE CONCRETE METER ,° .,...:: _.. ,:..... _ .,.:, .. ,... ,.. 21 ;:, 4" SHORT RADIUS 90° BEND FL. BOX NO. 2T (17%28") WITH 3/8" STEEL COVER PLATE CD "'T FINISH GRADE (TYPICAL) METER BOX SHALL BE DOUBLE STACKED. N z�'...:..16" ` 0 90° BEND F', FOR 2-1/2" 0 3" DCVA, USE UTILITY VAULT CO. MODEL 25TA OR EQUAL. n•. ` rri m 12" ALL AROUND cu Ci.l�• DEADMAN BLOCK � •: s . REQUIRED. CONCRETE BLOCKING L•.:.. .... •..,., .. _. .•.-.. • •. � I 4"x4"x4" TEE FL. ALL DETECTOR DOUBLE CHECK VALVE ASSEMBLIES SHALL INCLUDE RESILIENT SEATED SHUTOFF VALVES PLAN AND TEST COCKS. AND APPROVED CROSS -CONNECTION CONTROL ASSEMBLIES PER D.S.H.S. LATEST APPROVED LIST. 4" GATE VALVE Mi X FL WITH INDICATOR POST. DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESILIENT SEATED SHUTOFF VALVES. INDICATOR POST VALVE SAME SIZE AS DOUBLE CHECK VALVE 4"" FLANGED COUPLING ADAPTER (MUELLER CO. OR EQUAL). EQUAL TO ROMAC. 4" DUCTILE IRON CLASS 52 PIPE, CEMENT LINED, LENGTH TO FIT. NOTE: LOCATE VAULT IN PLANTING AREA NOT IN PAVING ' 4" PIPE 2. 4" AND LARGER BENDS AND TEES TO BE CAST FL. x SCREW IRON CEMENT LINED 3• TEMPORARY SUPPORT SHALL BE PROVIDED UNDER 2'-2" 2'-10" •' VALVES AT THE TIME OF INSTALLATION TO CENTER „ 4 DDCV ASSEMBLY THE PIPE IN VAULT OPENING. AFTER COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT 4" STANDPIPE W/2 2-1/2" NOZZLE AND INSTALL CONCRETE SUPPORT PAD OR 21 ADJUSTABLE PIPE SUPPORT. CROSS CONNECTION/BACKFLOW 4. INSTALL GALVANIZED LADDER FOR ACCESS. PROTECTION ASSEMBLY 5. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY r 4" 90 BEND FL. BY A DEPT. OF HEALTH CERTIFIED BACKFLOW Y i ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED\ O� ADOPTED cu TO CITY OF RENTON WATER UTILITY ENGINEERING CITY OF RENTON &R ' DEPT PRIOR TO ACTIVATION OF NEW LINE 6" MIN. DRAIN TO GALVANIZED STEEL qR LADDER 6. INSTALL BRASS PLUGS AT ALL TEST COCKS Standard plans DAYLIGHT OR STORM LST DATE: 3/7/95 DRAIN SYSTEM WITH F N CATCH BASIN OR MANHni COMPACTED FOUNDAiiuiv ,r-,r,VE_L - - - 3/7 95 EDITED TEXT AND DIMENSIONS DCV AG DATE REVISION I BY 1APPR'D DWG. NAME: BR56A SP PAGE: B098.1 UNION (TYPICAL) - Z c� TO CITY METER 12"- 16" CLEARANCE 6" CLEARANCE Z 0 1, TO PRIVATE SYSTEM AFTER FIELD INSTALLATION, DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO CITY 7/8" MINUS GRAVEL 12" MINIMUM OF RENTON WATER UTILITY ENGINEERING PRIOR TO ACTIVATION OF NEW LINE. AFTER TESTING & APPROVAL, PLUG ALL TEST COCKS WITH BRASS PLUGS. DOUBLE CHECK VALVE ASSEMBLY BELOW GROUND INSTALLATION FOR 3/4" TO 3" DOUBLE CHECK VALVE ASSEMBLIES � Y O ADOPTED CITY OF RENTON WL Standard plans N O� LST DATE: 3/7/95 3 7 95 IREMOVED VALVES, EDITED TEXT DCV AG DATE REVISION I BY JAPPR'D DWG. NAME: BR54 SP PAGE: B101 Rib, 276 SO 1; SCANNED MAY a 5 1999� �. rn rn rn \ N W W J J Li w U U of Z N U a to y :m m a. 00z o d J J Q' y Z Lil W 0 (n w z z o 0 Li ui � � U of w w w II.-a-aa �V)(nV) �000 a0LOLOV) yaaa Qwww �aaa W W W -� Y � 71) U V W W W p -» ­3m T �rnrnrn prn�� N\ N \ o M O z L LL J 00 w U_ U- U- O w w Z O co J w a Z Z w O U w Z O U 0 Z U Q J w = � Q cf)��"U W Z Z_ >- EE w Q Ift- Q < 0 0=DEL cow Q O > Z U o J O 'IT W W v 6 G N ° Q z c =II `° ui a�i y c Y 0 • 3 � a� U Q 0 Mmummm M AMA my N Z i 3 o Z w gN SJ _7 - LLJ X Q Z w Z LLI N �` g Z CD C-4 00 C� Z - CD NI 00 I Li ww a '� 3, In Z . �, U-) U0 W }}Z. W N Z N 00 LLJ Y N J 0 V) S�4§7 -- U L) w 69 a P G (/B� d►b, � of WAS N Go 5J41 r �i 75 Z DNA � -0 �' Lo bCANNED MAR 3 0 2000