HomeMy WebLinkAboutSWP2702817.544 2 SLOPE VARIES SEE PLAN EXISTING GROUND SEE PCC EXTRUDED CURB DETAIL THIS SHEET. 10" 6 ROAD R' E CURB AND GUTTER DETAIL THIS SHEET 8' BROOM FINISH SLOPE VARIES SLOPE TO DRAIN SEE PLAN 1 /4 PER 1" R EXISTING GROUND 4" PCC SATISFACTORY FILL SIDEWALK OR LEVEE EMBANKMENT 2" CLASS "A" ON 4" BASE IF WITHIN MINIMUM LEVEE SECTION. 6" CLASS "E" ON COURSE 6" CRUSHED GRAVEL SIDEWALK ON RIGHT SIDE OF ROAD ONLY FROM STA PRD 1+87 TO 2+90 MEET EXISTING. EXTRUDED S N LT OR PCC CURB NO SCALE B CURB, AND SIDEWALK NOTES: 1. A DUMMY JOINT CONSISTING OF 3/8 " OR 1 /4 X 2" PREMOLDED JOINT MATERIAL SHALL BE PLACED IN CURB AT A MINIMUM OF 15 FOOT INTERVALS. WHEN CURB IS PLACED BY SLIP -FORMING, A PREMOLDED STRIP TO 1 /2 " THICK AND UP TO FULL DEPTH MAY BE USED. 2. EXTRUDED CEMENT CURB SHALL BE ANCHORED TO EXISTING PAVEMENT BY EITHER TIE BARS OR ADHESIVE IN CONFORMANCE WITH WSDOT/APWA STANDARD SPECIFICATION SECTION 8-04. 3. EXTRUDED ASPHALT CURB SHALL BE ANCHORED BY MEANS OF A TACK COAT OF ASPHALT IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION SECTION 8-04. EXISTING PAVING TO BE REMOVED EDGE OF EXISTING PAVEMENT NEW AC PAVING •. �_� �L� ��� atm NEW BASE COURSE 12" MIN /1 i _ SAW CUT FULL DEPTH AND TACK COAT 12" MIN EXISTING BASE MATERIALS EXISTING AC PAVEMENT I VVLLV LVVL 1 Ir� 4 1 A 9) I IULI\UVl11\V VV„V , I ,LLER SECTION- CURB AND SI EWN LK JOINT NOT TO SCALE 5-1 2" [77 CIV 6-1/2" JOINT BETWEEN NEW AND F XISTI�(l FLEXIBLE PAVEMENTS NOT TO SCALE g ill F 11I wll� M,l � - n DETAIL SHOWS EXISTING MARKER CONSTRUCTION. CONTRACTOR SHALL REMOVE AND RESET MARKERS AS SHOWN OR REPLACE WITH APPROVED EQUAL IF DAMAGED. 24" MARBLE PLAQUE SET IN PCC G � a a o ISLE in 400 METER - r; n G 12" Ln CV G C-0 G � t�oL w\ GRAVEL BASE COURSE TOPSOIL AND SEED 1 /4 MICE MARKED DETAIL NOT TO SCALE 12" 24' 12" 8'—on NOT TO SCALE FILTER FABRIC MATERIAL USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE Lr: 2X2X14GA WIRE FAI OR EQUIVALENT WHITE STRIPING (TYP) 'A' C- 46 2X2X14GA WIRE FABRIC OR EQUIVALENT II II II II u 6' MAX I �,4 WOOD POSTS, STANDARD OR EQUAL ALTERNATE: STEEL FENCE POSTS SILT FENCE NO SCALE N OTE: PLACE SILT FENCE BETWEEN CLEARING LIMIT AND RIVER TO PREVENT UNCONTROLLED RUNOFF FROM ENTERING RIVER. REMOVE 3 WEEKS AFTER LEVEE HAS BEEN SEEDED. fv LAY FABRIC ON THE SURFACE J ON UPHILL SIDE AND PROVIDE 3/4 " — 1.5" WASHED GRAVEL BACKFILL „ ON BOTH SIDES OF FENCE 12 MIN 2X4 WOOD POST ALT: STEEL FENCE POST FTIL A NO SCALE �46 REVISIONS SYMBOL ZONE DESCRIPTION DATE B1' MODIFIED PER AS -BUILT INFORMATION 7/2001 JLM TRAIL OVERHEAD LIGHTING NOTES: 1, POLES SHALL BE LAMINATED, PRESSURE TREATED TIMBER, PACIFIC COAST D❑UGLAS FIR, THE PRESSURE TREATMENT SHALL BE PER AWPA STANDARDS P8, P9 AND C-28, POLES SHALL MEET NEMA DEFLECTI❑N REQUIREMENTS FOR 10OMPH WINDS INCLUDING A 1.3 GUST FACTOR. ABOVE GROUND M❑UNTING HEIGHT SHALL BE 20 FEET AND TOTAL HEIGHT 24.5 FEET, THE CROSS SECTI❑NSHALL BE 5— 1/8 INCH WIDE AND 4-1/2 INCH THICK, THE FINISH SHALL BE SMOOTH, 2. POLE INSTALLATI❑N SHALL BE PER MANUFACTURER'S REQUIREMENT, USING CONCRETE AT LEAST 24 INCHES DIAMETER AROUND THE POLE AND BETWEEN GRADE AND TO THE BOTTOM OF THE POLE, 1 INCH PVC C❑NDUIT SHALL BE RUN BETWEEN ACCESS HOLE AND JUNCTI❑N BOX INSTALLED 3 FEET FROM THE POLE, 3, JUNCTI❑N BOX SHALL BE INSTALLED NEAR EACH POLE FOR SPLICING OF CONDUCTORS. THE BOX SHALL BE WATERTIGHT, TESTED IN ACCORDANCE WITH NEMA 4, MATERIAL SHALL BE POLYMER CONCRETE AND HEAVY —WEAVE FIBERGLASS REINF❑RCEMENT, THE COVER SHALL BE SUITABLE FOR 8000 POUNDS SERVICE LOAD WITH "ELECTRIC" L❑G❑,, GASKETED, WITH 3/8 INCH 16—NC HEX BOLTS W/GASKET AND PULL SLOT, THE BOX SIZE SHALL BE 21-5/8 INCH LONG-11 5/8 INCH WIDE 8 59/64 INCH DEEP WITH OPEN BASE. 5, INSTALL 1 INCH PVC C❑NDUIT BETWEEN JUNCTI❑N BOXES AND TWO TIMER/METER BOXES, ONE NEAR THE STADIUM ALONG THE TRAIL AND OTHER NEAR REST ROOMS, THE C❑NDUIT SHALL BE INSTALLED 24 INCH BELOW GRADE MINIMUM AND STUBBED UP INT❑ JUNCTI❑N BOXES AND METER/TIMER BOXES. USE RIGID STEEL ELBOWS OR CONCRETE ENCASEMENT FOR STUB —UP TO PR❑VIDE RIGIDITY. PR❑VIDE METAL DETECTI❑N TAPE A FOOT BELOW GRADE AND ABOVE C❑NDUIT, 6, PR❑VIDE 2#8 AND 1 #10 GROUND WIRE IN C❑NDUIT/ JUNCTI❑N BOXES FOR USE AS FEEDER WIRE THE WIRES TO FIXTURE MOUNTED ON POLE SHALL BE 2#12 AND 1#12 GROUND. CONNECT EACH #12 PHASE WIRE TO #8 VIA 1 AMP IN —LINE WITERTIGHT FUSE AT THE JUNCTI❑N BOX. GROUND WIRES SHALL BE USED FOR GR❑UNDING ALL METAL PARTS, 7, EXISTING LIGHT FIXTURES SHALL BE REMOUNTED ON POLES AND CONNECTED TO WIRES/CIRCUITS PER EXISTING C❑NNECTI❑NS. FIXTURES ARE 100WATT, 0,52 AMPS 240 VOLT WITH H38 LAMP. 8, ALL ELECTRICAL WORK SHALL COMPLY WITH NFPA 70, NATI❑NAL ELECTRICAL CODE, 1996 EDITI❑N, STATE AND LOCAL CODES. Cli o-2sn3t, Ifs H I� lil -. IIII i IF SHEET IS LESS THAN 32" X 21 IT IS A REDUCED PRINT, REDUCE SCALE ACCORDINGLY U.S. ARMY ENGINEER DISTRICT, SEATTLE CORPS OF ENGINEERS SEATTLE, WASHINGTON LOWER CEDAR RIVER FLOOD CONTROL LEVEES & FLOODWALLS CIVIL DETAILS VII RENTON WASHINGTOP SIZE INVITATION NO. FILE NO. DATE: PLATE D B-99-0017 E-19-1-70 98DEC03 C-46 DS,,N. PWN CHK. SHEET 53 Swp -2 7 -2 4 3 r OMPUTER A IDED D E-N 8 D RAFTING 1 d' SCANNED SEP 13 2W2