Loading...
HomeMy WebLinkAboutSWP2702862.11v L v 0 C -o C v C 0 v E_ L v U E 4-1 D U 0 _0 v -C v a 3 41 C v U O -o 41 41 C 0 C 0 0 E 0 c v -C 41 0 C v 0 C 41 v L v v v N 0 s 41 c U ry r-� vi 41 v c- v -C v C v 0 r- 0 I cV I 0 rn Q 3 v U C v L 0 U U v E v U v 0 L U N a� v C rn C v v v 41 C v U O .D ACRONYMS AND ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT Al ANALOG INPUT AL ALUMINUM ALT ALTERNATOR AO ANALOG OUTPUT ASL ALARM SWITCH LOW AWG AMERICAN WIRE GAUGE BATT BATTERY BKR BREAKER C CONDUIT CA CHLORINE ANALYZER CT CURRENT TRANSFORMER CU COPPER DC DIRECT CURRENT DI DISCRETE INPUT DIST DISTRIBUTION DO DISCRETE OUTPUT ENCL ENCLOSURE EX ROOF EXHAUSTER EXIST EXISTING FAH FLOW ALARM HIGH FAL FLOW ALARM LOW FT2 SQUARE FOOT FE FLOW ELEMENT FI FLOW INDICATOR FIC FLOW INDICATING CONTROLLER FIQ FLOW INDICATING TOTALIZER FQ FLOW TOTALIZER FIR FLOW INDICATING RECORDER FIT FLOW INDICATING TRANSMITTER FSL FLOW SWITCH LOW FT FLOW TRANSMITTER FU FUSE FVNR FULL VOLTAGE NON REVERSING FVR FULL VOLTAGE REVERSING FY FLOW COMPUTATION G GROUNDING CONDUCTOR GND GROUND GRS GALVANIZED RIGID STEEL HC HAND CONTROL HP HORSE POWER IC INTERRUPTING CAPACITY KA KILO AMPERES KAIC KILOAMPERES-INTERRUPTING CAPACITY KCM THOUSAND CIRCULAR MILLS KV KILOVOLT KVA KILOVOLT -AMPERE KVAH KILOVOLT -AMPERE HOUR KVAR KILOVAR (REACTIVE KILOVOLT AMPERE) KVARH KILOVAR-HOUR KW KILOWATT KWH KILOWATT-HOUR LINE POWER LINE/POWER BLOCK LAH LEVEL ALARM HIGH LAL LEVEL ALARM LOW LI LEVEL INDICATOR LSH LEVEL SWITCH HIGH LSHH LEVEL SWITCH HIGH HIGH LSL LEVEL SWITCH LOW LSLL LEVEL SWITCH LOW LOW LT LEVEL TRANSMITTER LY LEVEL COMPUTATION LPU LINE PROTECTION UNIT M MAGNETIC CONTACTOR MA MILLIAMPERES MAX MAXIMUM MCM MILLION CIRCULAR MILLS MCP MOTOR CIRCUIT PROTECTION MEG MEGAOHM MF MAGNETIC FORWARD CONTACTOR MIN MINIMUM MR MAGNETIC REVERSE CONTACTOR MTS MANUAL TRANSFER SWITCH (ELECTRICALLY OPERATED) MV MILLIVOLT MW MEGAWATT MWH MEGAWATT -HOUR N NEUTRAL CONDUCTOR NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRIC MANUFACTURERS ASSOC. NESC NATIONAL ELECTRICAL SAFETY CODE OL OVERLOAD P POLE PAL PRESSURE ALARM LOW PE PRESSURE ELEMENT PF POWER FACTOR PH or 0 PHASE PI PRESSURE INDICATION PLC PROGRAMMABLE LOGIC CONTROL PRV PRESSURE REDUCING VALVE PS POWER SUPPLY PSI POUNDS PER SQUARE INCH R CIRCULAR CHART RECORDER RPM REVOLUTIONS PER MINUTE S MONITORING STREAMING CURRENT SEC SECOND SHL'D SHIELDED STD STANDARDS SUSE SUITABLE FOR USE AS A SERVICE ENTRANCE TB TERMINAL BLOCK TEFC TOTALLY ENCLOSED FAN COOLED TSP TWISTED SHIELDED PAIR UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VA VOLT AMPERE VMR VOLTAGE MONITORING RELAY W WATT WH WATT HOUR WP WEATHER PROOF XFMR POWER TRANSFORMER ZIC POSITION INDICATING RECORDER ZLL POSITION LIGHT LOW ZLH POSITION LIGHT HIGH ZSH POSITION SWITCH HIGH ZSL POSITION SWITCH LOW ZT POSITION TRANSMITTER ONE LINE DIAGRAM SYMBOL SCHEDULE SYMROI- DESCRIPTION DEVICE OR EQUIPMENT TERMINAL BUSSING CONNECTION BUS WIRING WIRING CONNECTED/SPLICED - - EQUIPMENT/DEVICE ENCLOSURE PLUG-IN CONNECTION T Il MAGNETIC ONLY BREAKER I I� THERMAL ONLY BREAKER I\ THERMAL MAGNETIC BREAKER / SWITCH FUSE M POWER TRANSFORMER CONTROL POWER TRANSFORMER CURRENT TRANSFORMER THERMAL OVERLOAD CONTACTOR T -I- CAPACITOR J- GROUND CONNECTION IVR VOLTAGE RELAY TR TIMING RELAY CR CONTROL RELAY F FLOAT SWITCH SV SOLENOID VALVE P PRESSURE SWITCH O LEVEL SWITCH FIT FLOW INDICATING TRANSMITTER [TS1 TORQUE SWITCH CONTR 0-❑80OA------ ( CA°LE/RANIGE) OAMMETER 3___----�- QUANTITY 0-60OV------ (SCALE/RANGE) OVOLTAGE METER 3_.---- QUANTITY 55---666HZ (SCALE/RANGE) ( F) FREQUENCY METER 1 QUANTITY 0-50OW-----___ (SCALE/RANGE) ONE LINE DIAGRAM SYMBOL SCHEDULE SYMBOL DESCRIPTION 81-- WATT HOUR METER QUANTITY AMS AMMETER SWITCH VMS VOLTMETER SWITCH [�G�] GENERATOR �S N SOLID NEUTRAL 15 MOTOR - NO. = HORSE POWER �o SAFETY DISCONNECT IN NEMA 4X ENCL. d UNLESS OTHERWISE NOTED AUXILIARY CONTACT r SEAL OFF ELEMENTARY WIRING DIAGRAMS SYMBOL SCHEDULE SYMBOL DESCRIPTION PANEL OR DEVICE WIRING -BY EQUIPMENT VENDOR FIELD WIRING -BY ELECTRICAL CONTRACTOR - - --- EQUIPMENT/DEVICE ENCLOSURE -+- 4- WIRING CONNECTED + -+- WIRING NOT CONNECTED 0-- DEVICE OR EQUIPMENT TERMINAL CONTROL PANEL TERMINAL --- MCC TERMINAL o-_ryyN-o TRANSFORMER WINDING --u::[]- FUSE-BUSSMAN FNM —14- _ OR -T�q- METAL OXIDE VARISTOR (MOV) —Ia— DIODE RECTIFIER GROUND ELEMENTARY WIRING DIAGRAMS ELECTRICAL PLAN DRAWINGS SYMBOL SCHEDULE SYMBOL SCHEDULE SYMBOL _ DESCRIPTION SYMBOL DESCRIPTION N.O. N.C. 6ELAY CONTACTS LIGJ ',1NG FIXTURES XXCR XXCR 111CR 2CR,ETSTANTANEOUS CONTACT OF RELAY CAA FIXTURE — WALLHIGH INTENSITYDIMOUNTED (HID) A,B,C, ETC. ARE SCHAGE ( ) XXTR XXTR TIMED DELAY CONTACT OF RELAY FLUORESCENT FIXTURE - B FIXTURE TYPE. REFER TO °T (DELAY ON ENERGIZATION-ON DELAY) SURFACE OR PENDENT MOUNTED FIXTURE (1TR,2TR,ETC.) C OUTDOOR LIGHT - SCHEDULE -XXTR XXTR TIMED DELAY CONTACT OF RELAY ❑ WALL MOUNTED 0- (DELAY ON DE-ENERGIZATION-OFF DELAY) (1TR,2TR,ETC.) YARD LIGHT POLE W/ FIXTURE(S) _ XXTR XXTR �--�-a-TIME RELAY CONTACT OF RELAY SWITCHING Y( (DELAY ON ENERGIZATION, DELAY ON DE-ENERGIZATION, ON DELAY/OFF DELAY) SINGLE POLE SWITCH � FOUR WAY SWITCH XOL X OL OVERLOAD RELAY $ WALL MOUNTED 4 WALL MOUNTED (10L,20L,ETC.) TWO WAY SWITCH �p SWITCH WITH --- -- $2 WALL MOUNTED PILOT LIGHT MAGNETIC COILS THREE WAY SWITCH CONTROL RELAY 3 WALL MOUNTED xcR (1CR,2CR,ETC.) RECEPTACLE OUTLETS XX TIMED DELAY RELAY DUPLEX RECEPTACLE OUTLET - WALL MOUNTED XTR (1TR,2TR,ETC.) (NEMA 5-15R UNLESS OTHERWISE SPECIFIED) XX MAGNETIC MOTOR STARTER ® SPECIAL PURPOSE EQUIPMENT CONNECTION M (1 M,2M,ETC.) SPECIAL PURPOSE RECEPT. OUTLET- WALL MOUNTED SOLENOID (FOR VALVE UNLESS OTHERWISE NOTED.) SPECIAL PURPOSE EQUIP. CONNECTION- WALL MOUNTED (1 SV,2SV,ETC.) PILOT LIGHTS (1 LT. 2LT. NEON TYPE LENS COLOR CODE A =AMBER W= WHITE R=RED \ , " �� B INCANDESCENT PUSH -TO -TEST G =GREEN P (CONNECT TEST CIRCUIT TO LINE) -.o , INDICATING INSTRUMENTS O AMMETER AM AMMETER RELAY H HOUR METER HIPS 150W 120V FIXTURE TYPE ". W/ PHOTOCELL _ - 20'-0" HIGH ELECTRICAL PLAN DRAWINGS ALUMINUM POLE SYMBOL SCHEDULE CONTACT BLOCK OPERATORS N.O. N.C. —0 �¢ PUSHBUTTON (1 PB,2PB,ETC.) MUSHROOM HEAD PUSHBUTTON (1 PB,2PB,ETC.) ❑1 O�D MECHANICALLY HELD PUSHBUTTON OPERATOR "OFF -ON" TWO POSITION SELECTOR SWITCH -0 o- (1 SS, 2SS, ETC...) 1 SC-1 SS OFF HAND I AUTO -+-o o+- I THREE POSITION SELECTOR SWITCH (1 SS, 2SS, ETC..) "X" = CLOSED IN THIS POSITION rt° °� SC-1 SS LS CONTACTS N.C. SINGLE BREAK CONTACTS PS -0 o- -<L---C>- DOUBLE BREAK CONTACTS (CONTACT BLOCK) PT N.O. N.C. MECHANICALLY ACTUATED SWITCHES XXFS XXFS FLOAT SWITCH SV _0_6°- __0_r (1 FS,2FS,ETC.) XXPS XXPS PRESSURE SWITCH LI -7 (1PS,2PS,ETC.) XXTAS XXTAS LS �o-� � TEMPERATURE ACTUATED SWITCH (THERMOSTAT) (1 TAS, 2TAS, ETC. ) LSH XXFLS XXFLS FLOW SWITCH _11111� -O,� (1FLS,2FLS,ETC.) PI XXDPS XXDPS DIFFERENTIAL PRESSURE SWITCH -(>k _0_X_6_ (1 DPS,2DPS,ETC.) PSL 0 -0XLoS- -o- � FREE LIMIT SWITCHES (1 LS,2LS,ETC.) El �� XXLS HELD TS hL.TB]LIE C WCD1FZ1[<S IDIE]Prr. -ENGINEERING-STREETS-WATER-SEWER-PARKS-BUILDING- POWER DISTRIBUTION AND CONTROL SWITCHBOARD/MOTOR CONTROL CENTER (MCC) FLOOR MOUNTED DISTRIBUTION/CONTROL EQUIPMENT PANELBOARD - WALL MOUNTED DISTRIBUTION/CONTROL EQUIPMENT SWITCH (SAFETY OR DISCONNECT) MOTOR STARTER (MAGNETIC) MOTOR STARTER (MANUAL W/OVERLOAD) MOTOR (NUMBER = HORSEPOWER) OPERATED VALVE INTRUSION DETECTION LIMIT SWITCH PRESSURE TRANSMITTER SOLENOID VALVE LEVEL INDICATOR LEVEL SWITCH LEVEL SWITCH HI PRESSURE INDICATOR PRESSURE SWITCH LOW PULLBOX/HANDHOLE TORQUE SWITCH by date CONSULTANTS designed MD 2/20/01 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON BERGER/ABAM 98003-2600 E N ZG i N E E R S> I N C. VOICE: (206)431-2300 FAX: (206)431-2250 drawn BJA 2/20/01 checked GLP 2/20/01 pro j eng CCW 2/20/01 proj dir GLP 2/20/01 field bk no HAND HOLE WITH COVER W/ FUSES AND QUICK DISCONNECTS GROUT BASEPLATE WITH NON -SHRINK SYMBOL DESCRIPTION CONTROLS O FLOAT SWITCH © LIMIT SWITCH � CONTROL PRESSURE SWITCH STATION SV SOLENOID VALVE �T THERMOSTAT SIGNAL SYSTEMS QS SMOKE DETECTOR < TELEPHONE - SINGLE LINE_ GENERAL WIRING SYMBOLS 0 JUNCTION BOX WIRING RUN EXPOSED IN BUILDING STRUCTURE UNLESS OTHERWISE NOTED — — WIRING RUN CONCEALED IN SLAB, UNDER SLAB IN CEILING OR WALL. OR BELOW GRADE. .- 4-,2MP ARROWHEAD INDICATES HOMERUN TO PANEL NOTED AT END OF ARROWHEAD. NUMBER INDICATES CIRCUIT WITHIN PANEL NOTED. LINE OR PHASE CONDUCTOR _ 1 — NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CROSSMARKS INDICATE QUANTITY AND USE OF CONDUCTORS. #12 AWG COPPER CONDUC- REQUIRED UNLESS OTHERWISE INDICATED CONTRACTOR TO INSTALL ANTENNA CABLE TO ANTENNA CONNECTION IN TELEMETRYi' PANEL ANTENNA AND ANTENNA CABLE CALVERT TECHNOLOGIES OR EQUAL TO TELEMETRY PANEL IN CONTROL ROOM. 2" GRS CONDUIT, SECURE TIGHT TO POLE FROM BASE OF CONC. TO BASE OF ANTENNA PER CITY REQUIREMENTS BOLT COVER ANCHOR BOLTS INSTALL PER POLE MANUFACTURER'S STD. GROUT & SILICONE 3/4" CHAMFER TYP. CAULK AT EDGE GRADE -IT1-_ I # •I ---I— I III--- J I '' I�--6-#5 BARS a Gib Iy _ EVENLY SPACED CONDUIT FROM w PANELBOARD "LC" n I I II ? I I III{ III I I z USE COMMERCIAL —' z CIRCUIT #5 II I I I III l GRADE CONCRETE 2#12, 1 #12G, 3/4 C _-/i/ 14n #4 HOOPS 08„ O.C. _ _ _ _ = = - � 9 I 8 O.C. TOP, BALANCE 0 12" 0. C. Q I I I l I I I II a _J--I---I-- `-' I I I I GI I I I I 1 �-- 2" CLEARANCE ANTENNA CABLE, SIZE PER 1'-6" NOTE: MFG'S RECOMMENDATIONS IN CONCRETE STRENGTH SHALL BE 3,000 PSI 1" PVC CONDUIT ROUND AT 28 DAYS. REINFORCING SHALL BE ASTM CONCRETE PIER A615 DEFORMED, GRADE 60. YARD LIGHT/TELEMETRY SCALE: N.T.S. s ELECTRICAL SYMBOLS ABBREVIATIONS AND DETAILS 113:41,15 SOUTH 180th STREET GRADE SEPARATION R 3/"/°5;REC°R° COPY -- - no date I revisions C40 H U sheet 40 of 144 job no A00084 scale_ AS SHOWN date 20-Feb-2001 Lost Soved on Wed Roy 18 2005 of OJ- 04PR by Hamilton 51e Nome.• 0.- 12000,A000841 CADD 1 dwgs I C-40, dwg Sco% 1