Loading...
HomeMy WebLinkAboutTRO4102893.1g v n IJ rt r ILI I ryV _ww Of ry M U O LLJ 7- 0 2 I a0 00 �41 C �' O o 8E� E-+ W 0:aD_ �C �_ E •_ E OIN C C a (D a a. m �m I :. w V) z 0 U E z 0 0 0 V) J of m I Q 0 z 30, 0 30' SCALE." 1" = 30' SEC. 4, TWP. 23 N., RGE. 5 E, W.M. FA F 1 0 F M IF A IF _' 4 _' .40 JF = i 'i aka HONEY CREEK HILL r J / a � 0 / f I�r r; I }� .. + i "q- / CALL BEFORE YOU DIG 1— 800— 424— 5555 UTILITIES UNDERGROUND LOCATION CENTER SHALL BE CONTACTED PRIOR TO CONSTRUCTION ACTIVITY IN PROXIMITY OF THE PETROLEUM TRANSMISSION PIPEL INE L OCA TED WES T OF REDMOND A ve NE M WM POPP ASSOCIATES 11399 �� �Q. Transportation Engineers / Planners RFGIST5: ��� 14-400 BLDG * #206 * 14400 BEL-RED RD FS�ONAL ENG BELLEVUE, WA. 98007 (425) 401-1030 EXPIRES 1 /2� CONTACTOR CABINET SERVICE & CIRCUIT NO. MAIN BREAKER BRANCH BREAKER CONTACTOR COMMENTS SERVICE 100 AMPS - - SERVICE CABINET A-1/240V — 15A 30A #0060 I C (` C kin �J TYPE I JUNCTION BOX LUMINAIRE (EXISTING OR BY OTHERS) +--i LUMINAIRE (NEW) ® NEW SERVICE CABINET — — — CONDUIT (NEW) WIRE NOTE 0 CONSTRUCTION NOTE - - R.O.W. ® PSE TRANSFORMER POLE SCHEDULE POLE NO. POLE I.D. # POLE STATION (FEET) POLE OFFSET (FEET) POLE HEIGHT (FEET) MAST ARM (FEET) LUMINAIRE TYPE CIRCUIT NO. COMMENTS 1 3835B 20+62 25 L 25 8 10OW, HPS, MC3 A-1 POLE ORIENTATION ANGLE 19' CLOCKWISE FROM OFFSET LINE 2 3837B 22+77 30 L 25 8 10OW, HPS, MC3 A-1 SEE AS —BUILT NOTE 1U 3 3839B 24+45 28 L 25 8 104W, HPS, MC3 A-1 GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS SPECIFICATIONS AND THESE PLANS. 2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 3. INSTALL ALL STREET LIGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT WHERE NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY, EXCEPT WHERE NOTED, 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL COORDINATE THE WORK WITH THE UTILITIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. 7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPECTION DIVISION (430-7203) FOR INSPECTION PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE ENGINEER. 8. ALL CONDUIT SHALL BE PVC SCHEDULE 40 UNLESS NOTED OTHERWISE. 9. ALL CONDUIT COVER SHALL BE 24 INCHES. CONSTRUCTION NOTES 0 INSTALL NEW FLAT LENS COBRA HEAD 10OW HPS, 240V, MEDIUM CUTOFF TYPE III DISTRIBUTION ON 25' DAVIT POLE WITH 8' ARM. ALSO INSTALL WSDOT TYPE I JUNCTION BOX (SEE STANDARD PLAN JR-36) AND PAD FOUNDATION. SEE POLE SCHEDULE. O2 INSTALL PHOTOCELL ON LUMINAIRE NO. 2. O3 COORDINATE WITH PSE FOR SERVICE TERMINI AT NEAREST PSE 120/240 SINGLE PHASE, POWER SOURCE. INSTALL CONDUIT (2" SCH 40) AND WIRE (3 #2'S) FROM POWER SOURCE TO SERVICE CABINET. 0 INSTALL SERVICE CABINET (#0060) ON NE 14TH COURT AT STA 35+95, 13' L. AS —BUILT NOTES �1 THE 2#8's FROM SERVICE CABINET (RUNQ2 ; LIGHTING) CONTINUE FROM LIGHTING PAD #2 JUNCTION BOX INTO POLE #2 HANDHOLE (NO SPLICES). TWO SPLICE KITS AND TWO FUSE KITS ARE IN HANDHOLE. 2#8's FROM HANDHOLE RETURN TO ADJACENT JUNCTION BOX IN SAME CONDUIT. L J TWO SPLICE KITS IN JUNCTION BOX EXTEND LIGHTING CIRCUIT (2#8's) FROM POLE #2 HANDHOLE TO POLES 1 AND 3. WIRING SCHEDULE RUN CONDUIT CONDUCTOR COMMENTS NO. SIZE 2" 2— 8 AWG USE—XLP) Lighting # (Schedule 40) 1—#8 Ground Ground 2" 2—#8 AWG (USE—XLP) Lighting �2 (Schedule 40) 3—#10 AWG (USE—XLP) Photocell 1—#8 Ground Ground 2" (Schedule 40) 1—#8 Ground 2" 4—#8 AWG (USE—XLP) Lighting (Schedule 40) 3—#10 AWG (USE—XLP) Photocell 1—#8 Ground Ground 2" (Schedule 40) Open Spare RECOMMENDED FOR APPROVAL BY BY BY G1 r'p 0 . or/ - iRe j / 1t • -7 z d SCANNED NOV - 7 2003