HomeMy WebLinkAboutWWP2702900.17INDICATE TYPE BY INSTRUMENT METER LETTER ELECTRICAL SYMBOLS LEGEND LINE TYPE LEGEND°e;Ae��� nL THERMAL MAGNETIC BREAKER OC MOTOR OPERATION COUNTER - --- - - EXISTING OVERHEAD POWER THERMAL OVERLOAD -� MAGNETIC BREAKER ONLY CIRCUIT BREAKER CIRCUIT BREAKER WITH EMERGENCY LIGHT WITH SELF CONTAINED BATTERY SINGLE RECEPTACLE, 120V SSRVS SSRVS -SOLID STATE REDUCED VOLTAGE STARTER - _ EXISTING UNDERGROUND POWER _ __'70NAL - EXISTING TELEPHONE -- -- PROPOSED TELEPHONE 16727 x "'C,eTee� a s e 2 os SIGGNEDNED: n/26/Of qM _ A - AMMETER VAR - VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER PF - POWER FACTOR W - WATTMETER V - VOLTMETER EH WATTHOUR METER VA - VOLT AMMETER T L Asp pY w'se"HAGy 22780 'Rb aec pe° ' �xaNA>. E�1RE5 / e 2001 SIGNED: ff/26/0f CURRENT LIMITING FUSE FUSE ---=moo FUSED SWITCH -O FUSE CUTOUT ST SHUNT TRIP SINGLE RECEPTACLE, 208V DUPLEX WALL RECEPTACLE , 120V WP = WEATHERPROOF G = GROUNDED OUNDED GROUND GF = GROUND FAULT INTERRUPTER DUPLEX FLOOR RECEPTACLE, 120V ti VARIABLE FREQUENCY DRIVE POWER TRANSFORMER /N/N CONTROL POWER TRANSFORMER 41 - FA FIRE ALARM CONDUIT - BIGNAL---- EXISTING SIGNAL 0/VOLT WIRING 18VOL 40 VOLT WIRING SIGNAL WIRING - - UNDERGROUND DIRECT BURIAL CABLE WIRING CONNECTED ABBREVIATIONS SPOT - SINGLE POLE, DOUBLE THROW SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW Wp - WEATHER-PROOF GFI - GROUND FAULT INTERRUPT P -POWER C -CONTROL --_�— SWITCH UNIT SUBSTATION, SWITCHGEAR, MOTOR CONTROL CENTER SPECIAL PURPOSE WALL RECEPTACLE, RATING AS NOTED TRANSFORMER '�'/ I�'�' .1. IIIJJJ J - INSTRUMENTATION PC - POWER & CONTROL CJ - CONTROL & INSTRUMENTATION BUS CONDUIT CONCEALED BELOW GRADE, IN SLAB - — — - OR WALL. LINE TYPE COLOR WILL VARY SURFACE MOUNTED PANELBOARD O CEILING JUNCTION BOX WALL JUNCTION BOX CURRENT TRANSFORMER DEPENDING ON VOLTAGE CONDUIT AND ERE EXPOSED OR SURFACE MOUNTED UNLESS OTHERESE NOTED. LINE TYPE COLOR WILL VARY DEPENDING ON VOLTAGE GENERAL NOTES 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE ELL---� APPEAR IN THIS SET OF PLANS. 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT FLUSHED MOUNTED PANELBOARD J FLOOR JUNCTION BOX VOLTAGE TRANSFORMER `- - GROUND - CONDUIT RUN UP THROUGH DEVICE OR FLOOR. LINE TYPE AND COLOR WILL VARY DEPENDING • CONTROL STATION -� EQUIPMENT MOUNTING STAND SINGLE PHASE MOTOR. HORSEPOWER AS NOTED WALL TELEPHONE OUTLET (+12") WALL TELEPHONE OUTLET (+60") FLOOR TELEPHONE OUTLET ❑ 75WATTS HEATER, WATTAGE NOTED HEATER �— UTILITY POLE AND GUY WIRE TTT SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER, THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAENGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS, CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS. LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. �' ON THE VOLTAGE AND INSTALLATION REQUIREMENTS. CONDUIT RUN DOWN THROUGH DEVICE OR FLOOR. LINE TYPE AND COLOR WILL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS. CONDUIT STUBBED UP AND CAPPED. LINE TYPE AND COLOR WILL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS. H y ` ' Fj z F-1 I -I L�" " �.y 7w Q O Z (n W 0 LL W 75 THREE PHASE MOTOR. HP HORSEPOWER AS NOTED L IY MOTORIZED LOUVER ACTUATOR SAFETY SWITCH COMBINATION MOTOR STARTER AND SAFETY SETCH O51 S MANUAL MOTOR STARTER FIRE ALARM PULL STATION F FIRE ALARM FLASHING LIGHT FIRE ALARM HORN F © POWER VAULT OK KIRK KEY INTERLOCK CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR APPROVED EQUAL PLUG-IN CONNECTION ^ ' (' J PIGTAIL, BARE COPPER, LENGTH AS REQUIRED, B' MINIMUM \ CONNECTION POINT, MECHANICAL, COMPRESSION TYPE. CA y y C Z' � � cn f HOME RUN TO PANELBOARD OR AS INDICATED CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED FLEXIBLE CONDUIT / I CONDUIT NTH SEAL FITTING _ I OFCONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS 5 0 o U y U rn a 0 0 � O E. z 14 Z FI.' z O 14 a m J Q W r ± 5 w ty+ N ...r Q r' W N GROUND ROD SIZED PER N.E.C. USE O EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. HH MANHOLE OR HANDHOLE MH p5 DISCONNECT SWITCH STANDARD SWITCH, 120VAC, 20 AMP BELL m BUZZER u H HEAT DETECTOR CAPACITOR T ENGINE GENERATOR GENERATOR CONNECTION RECEPTACLE SDO N SOLID NEUTRAL 'l7 Ci � UQ C N z a ..0 (� I ANDL UT INODICWTTIIEG CONDUIT SIZE, NUMBER y2" GRC, 2-q12 CALLOUT INDICATING CONDUIT PER SCHEDULE UNDERGROUND DUCT LINE (GONG ENCASEMENT) MIN 3-WAY SWITCH, 120VAC, 20 AMP ® SWAY O SMOKE DETECTOR TB TERMINAL BLOCK r UNDERGROUND DIRECT BURIAL CONDUITS RH2 ENGINEERING,INC. mtml:o,& 2 2.mm Mb 720b8052 1.800.720.805T 4-POSITION SWITCH, 120VAC, 20 AMP, LABEL SWITCH POSITION OHOA HAND -OFF -MOTION -PHOTO END OF UNE RESISTOR LA 7J 1 CA J O O O RELLINGHAMOFFICE 836 450 4 WeetHmt°n Rwd FLUORESCENT FIXTURE FACP FIRE ALARM CONTROL PANEL LIGHTING ARRESTOR _ ,...3 D O TESTED SHIELDED WIRE ROTHELL OFFICE 12 2100 t00 N NE 19 1951h Street, Suite 100 —0 0— 111 SURGE ARRESTER Q EAST WENATCHEE OFFICE 509.888.2900 WALL/CEILING MOUNTED FIXTURE INSTRUMENT METAL PIPE GROUND O 300 Si..Street, Suite 5 PORT ORCHARD OFFICE 600 K76s°7n6St-t. Suite 101 POLE MOUNTED FIXTURE / M ELECTRICAL PLUG MD MOTION DETECTOR LIMIT SWITCH LIMIT SWITCH -SQUARE D HEAVY DUTY TYPE C, CLASS OQ�O 9007 OR APPROVED EQUAL. SELECT ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING ON ACCESS HATCH. H �,� 29��� / SCALE: SHOWN 0 1" 2" WALL/CEILING MOUNTED EXIT LIGHT - DIRECTIONAL ARROW WHERE INDICATED SHADED AREA INDICATED ILLUMINATED FACE w WALL/CEILING MOUNTED EMERGENCY LIGHT WITH REMOTE BATTERY - - %�wP� 27 - Z pC PHOTO CONTROL CELL EYS EXPLOSION PROOF CONDUIT SEAL FIT-,I:G T CONTACTOR RTM MOTOR RUN TIME METER GROUND VACUUM BREAK SWITCH SCANNED OCT 0 g LO®% REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER JAN 24, 2003 RH2 ENGINEERING INC. DATE DRAWING F BAR IS NOT 2� SCALE LONG xn E_1 INGNEERDB el AlbJAN 24, 2DQJ IA ° �5 ip �. PAG No.: 101.082 INIxuL, KCC-EI