HomeMy WebLinkAboutWWP2702900.18WET WELL TRANSDUCER. SEE DETAIL ON DWG NO JG2 I O H ZSl _ H ZS2 LS2 DRY WELL � / Wd—IGFI CHECK VALVE UMIT SWITCH (TYPICAL) " SUMP PUMP MOTOR HP LS7 I M I wP ABOVE GRADE ZS4 TELEMETRY PANEL _ 3 (PNOVIDED BYCITIO © I 480V 42 KAIC M2-OL ELECTRICAL ENCLOSURE TELEMETRY ANTENNA. TO BE LIMIT SWITCH TO TURN ON WITH INTRUSION LIMIT SWITCH LOCATED IN THE FIELD DURING ASA OPEN ELECTRICAL ENCLOSURE DOORS. (TYPICAL EACH DOOR) CONSTRUCTION. ZS4 m _ A \ © A q 22780 0 AaCl aT41<V 600 AMP BUS, 480 VOLT, fiDHz, 34, 3 'MRE, 42,000 AIC �S7avat ps4'• ® 20A E%PIRES J 19 7004 3P 30V ; ( } 20A iTB s7cN8D: ff/2s/Ot 480V 20A 42 KAIC 20A wrw NEUTRAL'- POWER .e 20A METER 2 ~eA 20A _ �(n 20A CPT M2 CPTAll 20A m 16727 r 3P-30A M "ea a ev° NOTE 2 j - - NOTE 2 I ,... 20A 480V Kravn�'� _. 42 KAIC E e 2P 125A \. �. %P RES e 0 ` 480V I 100AT SIGNED: 11126101 42 KAIC I ` 125AF O Mi-OL� 111 ; /-. I I © I 240/120V 510A 100AT _ �j I GENERATOR 125AF CONNECTION RECEPTACLE ------------------- / CONDUIT PENETRATIONS TO VAULT AND ( DI' WET WELL. PROVIDE INSULATED I I I WP -- PLASTIC BUSHING. 1HOMAS AND — I I / BETTIS #226 TYPICAL WET WELL, I GFI \ VALVE VAULT AND HAND HOLES Q _ _ _ \ I I I I I I I I BFP ENCLOSURE �*------- -- 0 IA I IA I LEVEL TRANSMITTER BELLOWS ATTACHED TO SIDE OF VAULT I I I I I ELECTRICAL VAULT WATERPROOF PER MANUFACTURE'S CABLE SPLICE RECOMMENDATIONS I I I I I I I I I (TYPICAL) EYS I III -4�� CLASS 1 DIVISION EYS I I I ,AREA CLASS 1 DIVISION I Q 1 AREA ELECTRICAL VAULT I BELOW GRADE I I I I I PROPOSED ELECTRICAL 3'-8" L x I I 2'-8" W x Y-C H' ELECTRICAL I ( I I I VAULT FOR SPLICING JACKETED CABLE TO BUILDING WIRE. 4 UTILITY VAULT COMPANY MODEL # I A A 0'. A - — — — — 4� — — — — — — — — — 233-LA OR EQUAL. (TYPICAL). POWER RACEWAY SCHEDULE RACEWAY DESCRIPTION ORIGINATION TERMINATION A 1-1/4" GRC, 4-#3 SERVICE DISCONNECT UTILITY METER A2 1-1/4" GRC, 4-#3 UTILITY METER MANUAL TRANSFER SWITCH AS 1-1/4" GRC, 4-#3 Qt PAD -MOUNT TRANSFORMER SERVICE DISCONNECT A 1-1/4" GRC, 4-#3 MANUAL TRANSFER SWITCH GENERATOR CONNECTION RECEPTACLE 0 NOT USED - - © NOT USED - - A7 NOT USED - - A 2-#12, 1-#12 G TELEMETRY PANEL BREAKER 0 1/2" GRC, 2-#12, 1-#12G ELECTRICAL ENCLOSURE LIGHT BREAKER A 1/2" GRC, 2-#12, 1-#12G WET WELL LIGHT BREAKER n 1/2" GRC, 2-#12, 1-#12G VALVE VAULT RECEPTACLE BREAKER A 1/2" GRC, 2-#12, 1-#12G SUMP PUMP BREAKER A 1" GRC, 3-#10, 4-#14, 1-#10G MOTOR N0. 1 MOTOR STARTER A 1" GRC, 3-#10, 4-#14, 1-#10G MOTOR NO. 2 MOTOR STARTER A 2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. i MOTOR STARTER A 2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. 2 MOTOR STARTER A 1" ORO, 6-#14 FLOAT SWITCHES TELEMETRY PANEL A 1-1/2" GRC, JACKETED CABLE LEVEL TRANSDUCER TELEMETRY PANEL A 2" GRC, 3-FLOAT CABLES FLOATS TELEMETRY PANEL A 1- GRC, 5-#14, 1-#12G VALVE VAULT DEVICES TELEMETRY PANEL Q NOT USED - - © ANTENNA CABLE TELEMETRY RADIO ANTENNA A 1/2" GRC, 2-#14, 1-#14G INTRUSION ALARM SWITCH TELEMETRY PANEL A 1/2" GRC, 2-#12, 1-#12G GFI RECEPTACLE BREAKER ('O-wtO- 27— z,9cd ELECTRICAL EQUIPMENT LEGEND AO UTILITY METER ENCLOSURE - AS APPROVED 8 PUGET SOUND ENERGY. © GENERATOR CONNECTION RECEPTACLE - OUTDOOR RATED, 60OV, 100A, 4-POLE, 3-WIRE, THREADED CAP, WEATHERPROOF. CROUSE HINDS MODEL NO. AREA10486 OR EQUAL THAT MATCHES CITY-S EXISTING PLUG. © TELEMETRY PANEL - PROVIDED BY CITY, INSTALLED THIS CONTRACT. PROGRAMMING AND CONNECTION TO MASTER BY OTHERS. CONNECT TO PROPOSED SENSORS, ALARMS, AND DEVICES. Op WALL MOUNTED INCANDESCENT FIXTURE - EXPLOSION PROOF, 120 VOLT, 150 WATT RATED. FURNISH WITH 150 WATT EXTENDED SERVICE LIGHT BULB. APPLETON PART NOS. AALB-75 (BRACKET), AAU-15N (FIXTURE UNIT), AAGU-1 (ALUMINUM GUARD) OR EQUALS. FURNISH ALL NECESSARY CONDUIT AND SEALS TO MEET EXPLOSION PROOF CRITERIA. MOUNT AS HIGH AS POSSIBLE ON WALL O ELECTRICAL EQUIPMENT PANEL LIGHT FIXTURE - INCANDESCENT, 120 VOLT, 150 WATT RATED. FURNISH WITH 150 WATT EXTENDED LIFE BULB. HUBBELL MODEL VX-151 OR EQUAL. FO LIMIT SWITCH FOR ACTIVATING PANEL LIGHT. SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. © INTRUSION ALARM SWTCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. OH CHECK VALVE POSITION LIMIT SWITCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. SEE DETAIL. ON DWG NO. G2. QK FLOOD SWITCH - OMEGA MODEL LV-10 OR EQUAL MOUNT TO END OF 1/4" PVC PIPE AND SECURE TO WALL WITH MINIMUM OF TWO STAINLESS STEEL PIPE CLAMPS. SWITCH SHALL TRIP AT 1/2" OF WATER LEVEL IN VAULT. © WET WELL LIGHT SWITCH - AC QUIET TYPE 20 AMP SINGLE POLE. O TRANSIENT VOLTAGE SURGE SUPPRESSER - 6"x6"x6" NEMA 4 ENCLOSURE, ORION MODEL ORN-3Y 277/48OV. NO SUBSTITUTION. KIRK KEY INTERLOCK NOTE A KEY OPERATED MECHANICAL SWITCH WILL BE PROVIDED BETWEEN THE UTILITY 1� BREAKER AND THE GENERATOR BREAKER TO PREVENT BOTH POWER SUPPLIES FROM ENERGIZING THE MCC BUS AT Tr:- SAME TIME. ISA SYMBOL LEGEND LEVEL SWITCH LEVEL SWITCH oQ_o SPOT LIMIT SWITCH L T LEVEL TRANSMITTER �..-_ � _GROUNDING BUS #6 BARE COPPER GROUND I, ELECTRODE CONDUCTORS TO GROUND ELECTRODE PER N.E.C. 3/4%8' LONG COPPER GROUND ROD (TYPICAL ONE ROD EACH SIDE OF ELECTRICAL 0 ENCLOSURE) 0 KWH O 0 100 AMP FUSED SERVICE ENTRANCE SWITCH. F Too AM N AM PAD -MOUNT TRANSFORMER SECONDARY 48OV, 3-PHASE, 4W. 0 wwr -�7 4 KENSINGTON CREST CONDOMINIUMS & LIFT STATION Page 18 of Zia S - ?991018 REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER JAN 24, 2003 RH2 ENGINEERING INC. DATE SCANNED OCT 0 8 Zc"7� I AS-BUILTS DJB MM 11 NO. I REVISION I BY I REVIEW p E-4 Q ^ U Q a � �a O C U VU2 W W N W J s ai H >. Ul 0 aPPP��411 ENGINEERS PLANNERS SCIENTISTS RH2 ENOINEERINxs, INC. m&hZ llp ./mm rhl I.800.720.8051 — I INGHAM OFFICE 360.676.0836 454 West Harlan Road BOTHELL OFFICE 425.951.5400 12100 NE 195th Street, Suite 100 EAST WENATCHEE OFFICE 509.886,2900 300 S.. St—t, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kilsap Street. Suite 101 SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG xpr: 24 1 .... wa— DMB I E_2 JAN 24, 2003 ,T. PAG 101.082 INIE KCC-E2