HomeMy WebLinkAboutWTR2702953.101AI B C D E I F I G 1H I J K L M N 0 P FAIL FAIL FAIL FAIL FAIL FAIL TREAT FAIL YA YA YA ZI0 YA YA YA YI PDI PDAH YA ZIO LO HOC & 424A ZI 426 FI FQI 425A ZIC 434A YA FAIL 421 A ZI 418A YA 415A FI FQI 401 A YI 401 401 LAL 433A ZIC 433A � PLANT TYPICAL OF 3 N 424 406A 406 434A 434A 418/YI 412A 401A 401 YA 401B 433A 01 401 D FAIL 401A BACKWASH 1 0 f� 1 ON LINE 1 FAIL N CONTROL--� I I----------� OFFYPANEL 2 I434 I I---------401 _------------� RTU 9 9 1 I 1 I 1 1 I 1 OF ON/F I I 1 I' ON/OFF ON/OFF I I HS i I I I HS HS I I I I I I 1 HS OCA Z O OPEN ZIC CLOSE YA AIL I I I I 401 1 I I 1 402 403 j I 1 j I I 434 434B 434B 434C 1 I 1 j FAIL IN B/W I FAIL IN B/W FAIL IN B/W I I I I j I j ZSO ZSC (SEE NOTE " 1 I j I YI YA I` I YI YA YI YA _I I 11 1 434 434 1 1 1 1401D 401 I I 1 I 402D 402 403D 403 1 1 1 I M 1 1 , (SEE NOTE 3) 1 I I I (SEE NOTE 3) (SEE NOTE 3) I 8" TW BWS 1 1 1 I I 1 I 1 8„ Tw 1 TW 8 I 1 / 1 1 I 16/A 8 1 I 1 I I 1 /2" SA #6 1 1 SAMPLE WATER i V-434 1 1 I I 112/ F I I I I 1 I I 1 I I I I 1 1 1 R„ `1, 11 i I I I i 1 I I I 1 I 1 I i I I I I I I 8 GAW I 1 1 I I I I I I I I 1 I I 1 I I OCA OCA 1 OCA OCA OCA OCA I i 1 j I V-410 I i HS ZSO HS ZSO 1 HS ZSO HS ZSO HS ZSO HS ZSO I 1 I 0 ! I I 412 412 415 415 1 413 413 416 416 414 414 417 417 I i 1! 1 1 1 I 1 •� 1 I ZSC 1 ZSC I 1 ZSC ZSC I ZSC I ZSC 11 I I I I I V-409 1 I 1 1 001 I 1 412 I 415 I 1 413 1 416 1 414 417 RAW WATER I I I I I 16 RW BY-PASS I I ( I I I I I I 16" GAW I I GAC TREATED WATER 2/A 1 I I I I I 1 4/A 6 1 I I V-411 I I I 1 1 j j 1 I 6 I I I N.C, I L I I I 1 1 1 1 1 1 1 i 1 I 1 I 16 RW 1 1 1 1604 I 14 RW I I I TW 1 I i I 1 I I I I I 4/ C I I I I ---- �- n +- -- - 1 1 1 I I 1 1 M I M M CAW 14/ D 1 I 1 1 1 AO7GAC I > > 1 1 11 V-429 I I 1 I 1 V-426 I I 1 1 1 I IMV_41M O_�MV-417I OCA I OCA I I I I I 5 I � V-416Lj f 1 426 II NZSO I I 1 I (ZSO ZSC 425 I 1 I 1 I I 1 a� >01426 426 ZSC 1 IPDIT _ PDIT PDIT8" TW/BWS 425 M - I ! 11 401 41, I I 1 1 8 402 403I i ES I FI I GAC-402 GAC-403 N I I I 1_ FIT FE V-425 I I HS OCA I 401 � OCA OCA -CF7 -- O I I HS HS N t- 406 406 1 418 I FIT 419 420 Q �- - I -� - - ! ES 401 o ES 4 2 o ES 403 o w 4 I V-424 N ! I 1 1 I � m I w m 1 1 4 NM Q 1JFAI A O I 1 I I M o e OCA �+ OCA �� oO OCA OO I I FE �j 10x8 w FE �1 10x8 wZT FE �1 10x8 w 0 1L w 418 M HS 401 (TYP) v 1 419 M HS 402 (TYP) �' 1 420 M HS 403 (TYP) 1 N I v� 421 422 0 42308x6 8x6 8„ CAW �f- E 8x6 8x6 8„ GAW �E-{ 8x6 8x6 8" CAW �- - - - - ZT M � M "-) M `n 424 - I V-442 - V-444 ® • FL V 418 1 0 I V 419 0 i rCV 420 V-423 0 o I M V-421 B-i� > �{� M V-422 �� > ®� M > �K 1 i FL 1 1 3 T 3 I 16 CAW 16x 14 T 14 CAW FL T I 3 � V-433 I i ci, cn O o ZSO ZSC ZSO ZSC ZSO ZSC OCA 1 v' 421 421 cn 422 422 �' 423 423 °� M HS 1 1 - - - - - - - - J m � '� � 433 � I Ne,m 8" BWD °O 8" BWD I BACKWASH DRAIN 1 4/13 00 ZSC ZS0 8 BWS- - - - - - - - - - - - -----� o 433 433 U W 2 2 3 o o NOTES: W=2953116 Q 1. TYPICAL FOR OCA NON -MODULATED OPEN -CLOSE VALVE SWITCHES. OPEN 2. TYPICAL FOR MODULATED OCA VALVES. FAIL INDICATOR LIGHT ON HS RECIEVES RTU 3. TYPICAL FOR GREENSAND FILTER AND GAC FILTER SELECTOR SWITCHED. SWITCH RECORD DRAWING U These Record Drawings hove been prepared based on information provided i AND CLOSE LAMPS WIRED THROUGH ACTUATOR. FAIL LAMP CONNECTED TO OUTPUT TO INDICATE FAIL. HS OPEN AND CLOSE POSITIONS ARE USED TO INCLUDES INDCATOR LIGHTS POWERED BY RTU TO SHOW BACKWASH AND FAIL by the contractor and others. Kennedy/Jenks Consultants has not verified the CONTROL OUTPUT. CONNECT SWITCH TO CONTROL INPUT TO SHOW AUTO MANUALLY ADUST VALVE BY PRESSING CENTER BUTTON OF HS. TYERE ARE NO CONDITIONS. accuracy or completeness of information provided them and does not jwarrant the accuracy or completeness of these Record Drawings. Users of L0 POSITION. REFER TO 1 14. ILLUMIUNATED INDICATORS FOR FULL OPEN OR FULL CLOSED. these Record Drawings assume all risk of loss resulting from their use. CD SURVEYED: SCALE: NONE CITY OF RENTON DATE: N &� rs i DESIGNED: MDL DLW VERTICAL: NAVD 1988 =Planning/Building/Public Works Dept.DEC 2005 ECONOMIC AND ENGINEERING i DRAWN: LMM ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/JenksSERVICEs, INC. PROJECT No. 3-01-358 J CHECKED: MDL MAPLEWOOD AT FULL SCALE Consultants APPROVED: 10900 NE 4th STREET, SUITE 1110 WATER TREATMENT AND GOLF COURSE IMPROVEMENTS REVISION No. 32001 32nd Avenue South, Suite 100 (E DATU M BELLEVUE, WASHINGTON 98005 IF NOT ONE INCH Federal Way, Washington 98001 sHT NO. Y — RECORD DRAWING 12/05 SCALE ACCORDINGLY PORTLAND, OR _/ BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA GAC SYSTEM DWG No. z L.NO. REVISION BY DATE APPR 1 3R J A B C ID E F G H � M N — W 21915 3 Al A b r 0 0 y 0 d a � 1 0 y N o � N Z � b 1 N C r� z y w