HomeMy WebLinkAboutWTR2702953.103A co L HQC & N PLANT 01 N CONTROL PANEL 2 RTU 9 XCN � 801 � I I I I I I I I I I I I I I I I I I I I I I J- J_ I RECYCLE WATER I I RAW WATER BYPASS I C I D I E j F G ) H FAIL FAIL FAIL FAIL FAIL FAIL (A YA YA YA YA YA ZIC FQI LAL FQI )4D YI 403D YI 402D YI 401 D YI 810B YI 81 1 B YI 810 ZIC 801 FI LI 802 LAH FI 802 404B 403E 402E 401 F 810B MAN 81 1 BMAN ` 81 1 801 802 802 802 1 1 t 1 FY----------- --- FC LC FC 401 801 80 80 � I 1 I I I I I 1 I I I I I I 1 I �_j l I I 1 I I I i I I I I I I I I 1 I I 1 I I I I I I 1 I I I I I I I I I I I I I I 1 I I I I I I I I 1 1 I 1 I 1 I I I I I 3" BWR I 1 I L I 1 I I I 16" RW I 1 I J I K I L VFD FAIL VFD FAI L YA YA YA YA FIC FAL FI LAH 302D YI 302B YI 301 D YI 301 B YI 311 FALL 311 FAH 311 FQI 301 302C 302B 301C 301B 311 311 311 EMP EMP , I (SLO ------—FC---- 1 311 I _ � 1 �----- — — — I I I I I I i I I I I 1 I I I I I I I I I I I I I I I — 1 11/A — I 10/ A 10 -9 8 I I I I I I j I I I j I 1 I I I 1 1 I 1 I I 11 1 I I 2 I 2 I 1 I 1 I I I I I I I 0 i I I I I i 1 i 0 i 1 I I 1 I 1 1 /2 SA #9 1 1 1 SAMPLE WATER 112/ K HS 1 I I I I I I I I I I i 1 HOA 1 i I I T 1 1 I HS I I " 302 I I I I 1 I I 12SA #11 SAMPLE WATER 7 112/ L I I I 1 I 1 I i I I i 3x21 i I I I I I 1 I 1 I I I I I 0 1 1 /2" SA # 12 SAMPLE WATER FIT i l i i I I 1 I I I I I I T1 i ES 311 112/M I 1 I I I 1 1 1 1 I I 11 i M I I � I I I I I I 1 I I I I 1 1 I I I I I I I HOA 302 i FE 1 FILTERED WATE I I I I I I 16" FW I I I I I MHO HS I YY I 311 (N E) 1 4/ A SAMPLE 301 I 302 I 0 V-359 ) I I I 1 I I 1 BOOSTER I I 18x 16 18" BCW 18x 12 18x 12 0 6 I I i I I I 1 I PUMP YS I M 6 3 3 I 11 11 I 3 3 FIT ES I I I 1 1 P-304 301 I 12' BCW 1 I I I I I I V-346 I 801 I I I I 16x 14 I 18x 14 18x 14 RFPI ACE HOA HOA OCA OCA HCA HOA I I 1 I 1 301 V_ 4 V_ ( ) 1 � I 35 I 353 1 J E VALVES HS HS HS HS HS HS I i i I 1 0 0 (N) (E) 403 404 810 811 I 401 402 FE I I I Sic SIC N i FILTERED m i I I I 801 I I I I LSH 301 302 16x 12 1 WATER o I I I I V-356 PI V-355 PI „ I 1 1 I I 1 I 301 O 301 O 302 � 16 BCW , 16 BCW W 1 I YS YS I 1 I l YS YS I I I I m Q 5 I I 403 404 1 I I I 401 402 11 I I 301 M m > M m M 1 I o� 6 rj I I I I I i I I I YY j I I 1 I I to j CHLORINE 0� 0 0 0 I (N) (E) 1 403 404 I 1 I 401 402 I 1 r., 1 I I I I � 1 LIT CONTACT N I I 1 I > 1 301 CHAMBER I 1 I - I I � V-358 12" BCW i I V 832 0 1 I l I I I o I 1 I I 2 BWR I I >> o 1 I I 1_ I I i 0> I i i 12 OF N 1 I I I 2 BWW ®SA I Cn T Q 4 I I d-- � l 1 `1 SA A I I IE ^ n �� ,,,� �� i 4 1 I 1 1 0 1 I 1 IIII-- 1 1 00 > > I I 1 a000-o 00I I LOW-LIf 1I LOW -LIFT LLJ1 1 I> > I I LE PUMP PUMP i I I I I FIT FE 301 — - TO STORM DRAIN �' i PI °� PI °O YV YV I PI PI I 1 802 802 P-301 P-302 LP=303� 1 403 > 404 > 810 8 1 401B 402 I 1 ES FUTURE 1 i I I 1 2" BWW LSH 801 ( M M I 1 M > M > 1 M ry Ln 0 1 1 I M PSI 1 �i 3 LSL LIT I" r I I ,n,� LSL LIT 3 0 801 801 A i 802 802 BACKWASH SANITARY DRAIN SEWER o MANHOLE 1 5 / B I iO'SANITARY Y ZSC SEWER i G_81811 DRAIN 10" CCD 0 0 0 8 12/F o G-81 1 OF o w 2 2 a, LE n n G-812 n n 0 801 LE W=2953118 Q BACKWASH BACKWASH BACKWASH BACKWASH 802 RECORD DRAWING 0 WASTE PUMP WASTE PUMP BACKWASH BASIN RECYCLE PUMP RECYCLE PUMP These Record Drawings have been prepared based on information provided TO STORM DRAIN by the contractor and others. Kennedy/Jenks Consultants has not verified the �) P-403 P-404 P-401 P-402 accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. CD SURVEYED: SCALE: NONE 1 CITY OF RENTON DATE: 1 � DESIGNED: MDL DLW VERTICAL: NAVD 1988 DEC 2005 ECONOMIC AND ENGINEERING Pic nning/Bui►ding/Public Works Dept. i DRAWN: LMM ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks PROJECT NO. CHECKED: MDL ConsultantsSERVICES, INC. MAPLEWOOD 3-01-358 AT FULL SCALE o APPROVED: 10900 NE 4th STREET, SUITE 1110 WATER TREATMENT AND GOLF COURSE IMPROVEMENTS REVISION NO. _ 32001 32nd Avenue South, Suite 100 BELLEVUE, WASHINGTON 98005 IF NOT ONE INCH DATUM Federal Way, Washington 98001 SHT NO. Y RECORD DRAWING 12/05 SCALE ACCORDINGLY PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA BACKWASH HANDLING SYSTEM CHLORINE CONTACT CHAMBER - DWG NO. Z NO. REVISION BY DATE APPR 1 5R A B C D E [_ G H I J K L M N WAllSCAN NI2953AA ,, Y ' 'N y I w