co ABBREVIATIONS PLAN SYMBOLS SINGLE LINE SYMBOLS ELEMENTARY DIAGRAM SYMBOLS
LO
CROSS REFERENCE TO
A AMMETER, AMPERES KVA KILOVOLT AMPERES - - S GROUND CONNECTION ® FUSE. RATING IN AMPERES ANOTHER DIAGRAM 10
KVAR KILOVOLT AMPERES REACTIVE UNDERGROUND CONDUIT * SINGLE POLE SWITCH NORMALLY OPEN CONTACT
N AF AMPERE FRAME * 2 = 2 POLE, 3 = 3 WAY, 4 = 4 WAY, SWITCH, 3 POLE EXCEPT WHERE NOTED.
AFD ADJUSTABLE FREQUENCY DRIVE KW KILOWATTS K = KEY OPERATED -0�� ON THE OTHER DIAGRAM
AFF ABOVE FINISHED FLOOR KWH KILOWATT HOURS - - UNDERGROUND DUCT LINE RATING IN AMPERES AS NOTED MO MOTOR ETM ELAPSED TIME METER
WP =WEATHERPROOF
AIC AMPERES INTERRUPTING CAPACITY LP LIGHTING PANEL oo (CONCRETE ENCASEMENT) AUTOMATIC TRANSFER SWITCH 1 2-2, 3, 0, 0
0 o NOTE P3 D DIMMER CONTROL DEVICE COIL. PREFIX NUMBER, CR
APPROX APPROXIMATE LTG LIGHTING P SWITCH WITH PILOT LIGHT 3 POLE, RATING AS NOTED * * WHEN USED, DISTINGUISHES BETWEEN SPARE CONTACTS ON RELAY.
AT AMMETER TRIP LTS LIGHTS IF OMITTED THEN THE SPEC.
ATS AUTOMATIC TRANSFER SWITCH (M) MODIFIED - oo UNDERGROUND DIRECT SC' SINGLE POLE SWITCH (NOTE P2) ST SHUNT TRIP DEVICES OF THE SAME TYPE. REQUIREMENTS REGARDING
AUTO AUTOMATIC mA MILLIAMPERES o o BURIAL CONDUITS NOTE P3 * FUSE ALT - ALTERNATOR LR - LATCH RELAY SPARE CONTACTS APPLY.
® SOLENOID VALVE CONTROL RELAY SV - -
BCG BARE COPPER GROUND MCC MOTOR CONTROL CENTER MULTIPLE. CONDUIT RUN ab � FLUORESCENT FIXTURE CR NORMALLY CLOSED CONTACT
g BLDG BUILDING MCP MOTOR CIRCUIT PROTECTOR (NOTE P2) FUSE CUTOUT GR - GENERAL RELAY PR PROBE RELAY ON THIS DIAGRAM 9
- - C CONDUIT, CONTACTOR MFR MANUFACTURER b .CIRCUIT BREAKER, 3 POLE EXCEPT WHERE ISR RELAY
INTRINSICALLY SAFE TR TIMING RELAY
CB CIRCUIT BREAKER MIN MINIMUM FLUORESCENT FIXTURE WITH OMCPb OOOAT
CKT
CIRCUIT
MISC
MISCELLANEOUS
- - - - - - - - CONCEALED CONDUIT IN
NIGHT LIGHTING (UNSWITCHED)
4 OOAT 4 OOOAF
NOTED. RATING IN AMPERES AS NOTED. IF TWO
RATINGS APPEAR (EG. 100/625) THEN DEVICE IS
�
INDICATING LIGHT
CO
COND
CONT
CONDUIT ONLY
CONDUCTOR
CONTINUED, CONTINUATION
MOV
MS
MTD
MOTOR OPERATED VALVE
MOTOR STARTER
MOUNTED
WALL AND CEILING
CONCEALED CONDUIT IN
OR
FLUORESCENT FIXTURE WITH
SELF-CONTAINED EMERGENCY
BALLAST/BATTERY
MCP; NUMERATOR IS CONTINUOUS CURRENT
RATING & DENOMINATOR IS INSTANTANEOUS
*
PUSH -TO -TEST
LIGHT
CID
CONTROL PANEL
'(N)
NEW
FLOOR
TRIP SETTING.
�o
..INDICATING
* COLORS:
CT
CURRENT TRANSFORMER
NEC
NATIONAL ELECTRICAL CODE
I
WALL/CEILING MOUNTED FIXTURE
o—II�
SURGE ARRESTER
A - AMBER R - RED
CWP
COLD WATER PIPE
NEMA
NATIONAL ELECTRICAL
EXPOSED CONDUIT
B - BLUE N - NEON
8
DIA
DIAMETER
MANUFACTURER'S ASSOC.
'
WALL/CEILING MOUNTED FIXTURE
C
CURRENT TRANSFORMER
C - CLEAR W - -WHITE
DIAL
DIAGRAM
OIT
OPERATOR IN TROUBLE
CALLOUT INDICATING CONDUIT
NIGHT LIGHTING (UNSWITCHED)
G - GREEN Y - YELLOW
DISC
DISTR
DISCONNECT
DISTRIBUTION
PB
PM
PUSHBUTTON
POWER MONITOR
SIZE, NUMBER OF WIRES AND
3/4"C-3 12
#
E-
VOLTAGE TRANSFORMER
TERMINAL
DN
PNLBD
PANELBOARD
WIRE SIZE
o-
POLE MOUNTED FIXTURE
DP
DOWN
DISTRIBUTION PANEL
PS
PVC
PRESSURE SWITCH
POLYVINYL CHLORIDE
WALL/CEILING MOUNTED EXIT
WJJ
rrM
POWER OR DISTRIBUTION TRANSFORMER
RATING AS NOTED
SINGLE POLE SWITCH
DWG
DRAWING
PWR
POWER
T INDICATING CONDUIT
CALLOUT D C ATIN G CO DU
b b
LIGHT - DIRECTIONAL ARROW
(E)
EXISTING
RCPT
RECEPTACLE
PER SCHEDULE
100
WHERE INDICATED, SHADED AREA
EMERGENCY PUSHBUTTON
EF
EXHAUST FAN
REQD
REQUIRED
INDICATES ILLUMINATED FACE
100
MOTOR. NUMBER INDICATES HORSEPOWER
-0 o-
EHH
ELECTRICAL HANDHOLE
R
O
RELOCATED
CONDUIT RUN, HATCH MARKS
I
PUSHBUTTON,
7
ELEC
ELECTRIC, ELECTRICAL
RM
ROOM
INDICATE NO. OF #12
EMERGENCY LIGHT WITH SELF
GEN
GENERATOR
-0 0-
NORMALLY OPEN / CLOSED
ELEM
ELEMENTARY
SACP
SECURITY ALARM CONTROL PANEL
CONDUCTORS NO HATCH MARKS
IS
CONTAINED BATTERY
EMERG
EMERGENCY
SF
SUPPLY FAN
2 12 UNLESS OTHERWISE NOTED
#
CONTROL PACKAGE PROVIDED WITH
-°�°- -°�°-
SWITCH,
ETM
FLUOR
ELAPSED TIME METER
FLUORESCENT
SPECS
SS
SPECIFICATIONS
STAINLESS STEEL SOLID STATE
A
O
LIGHT FIXTURE IDENTIFICATION
o
THE DRIVEN EQUIPMENT
I
1-POLE / 3-POLE
FREQ
FREQUENCY
SW
SWITCH
FLEXIBLE CONDUIT
BUS STAB ON MCC OR SWITCHGEAR, CORD
'
I
FU
FUSE
SWBD
SWITCHBOARD
& PLUG CONNECTION FOR MOTORS
(F)
FUTURE
TB
TERMINAL BOX, TERMINAL BOARD
CONDUIT RUN, BROKEN AND
Fe
SINGLE RECEPTACLE, 120V
GALV
GALVANIZED
TC
TELEPHONE CABINET
CONTINUED ON SAME SHEET
* A - AMMETER
GEN
GENERATOR
TEL
TELEPHONE
OR AS NOTED
F
SINGLE RECEPTACLE, 208V
O
V - VOLTMETER
a
MULTI -POSITION SELECTOR SWITCH
6
GFI
GROUND FAULT INTERRUPTER
TEMP
TSP
TEMPERATURE
TWISTED SHIELDED PAIR
WH - WATTHOUR METER
o
GND
GROUND
GS - GROUND FAULT SENSOR
0
H A
GRS
GALVANIZED RIGID STEEL
TYP
TVSS
TYPICAL
TRANSIENT VOLTAGE
I / I
—� CONDUIT WITH SEAL FITTING
I:
DUPLEX WALL RECEPTACLE, 120V
WP = WEATHERPROOF
AS
AMMETER SWITCH
HAND -OFF -AUTOMATIC SWITCH
HOA
HAND -OFF -AUTOMATIC
SURGE SUPPRESSOR
G = GROUNDED
X-INDICATES CONTACTS CLOSED
HOR
HAND -OFF -REMOTE
UGND
UNDERGROUND
IG = ISOLATED GROUND
VS
VOLTMETER SWITCH
HPS
HIGH PRESSURE SODIUM
UH
UNIT HEATER
] CAP ON CONDUIT STUB
GF = GROUND FAULT INTERRUPTER
HWL
HZ
HIGH WATER LEVEL
HERTZ (CYCLES PER SECOND)
V
VA
VOLTS
VOLT-AMPERES
OPEN CIRCLE DENOTES UPWARD
ELEMENTARY DIAGRAM NUMBER
H 0 R
8
7
6
W WIRE, WATTS CONDUIT RISER DOUBLE DUPLEX WALL RECEPTACLE HAND -OFF -REMOTE SWITCH
K KIRK KEY INTERLOCK
120V ' ' X-INDICATES CONTACTS CLOSED
INCAND INCANDESCENT WP WEATHERPROOF - , ELEMENTARY DIAGRAMS
INSTR INSTRUMENT, INSTRUMENTATION WW WIREWAY
.SOLID CIRCLE DENOTES DOWNWARD - � � I �
5 JB JUNCTION BOX XFMR TRANSFORMER CONDUIT RISER POWER RECEPTACLE FOR T° E1 UNDERLINED WORDS SHOWN AT A PUSHBUTTON, 5
KV KILOAMPERES 0 PHASE MULTI -OUTLET ASSEMBLY WITH PORTABLE EQUIPMENT
SINGLE RECEPTACLE120V LIGHT, SELECTOR SWITCH, ETC. INDICATE THE
,
KCMIL THOUSANDS OF CIRCULAR MILS INDICATES REMOVAL HN3 H2 H4 LEGEND PLATE REQUIREMENT FOR THAT PARTICULAR
KV KILOVOLTS JX IN. SPACING (X INCHES) AS NOTED, RELAY DEVICE FUNCTION, # DEVICE. ANY ADDITIONAL NAMEPLATES ARE
F FIRE ALARM CONDUIT MOUNTING HEIGHT AS NOTED # PER ANSI NUMBER C37.2 CONTROL POWER TRANSFORMER INDICATED ON ELEVATIONS WITH THE REQUIRED
�D RECEPTACLE, 480V X1 X2 NAMEPLATE INSCRIPTIONS.
GENERAL NOTES. T TELEPHONE CONDUIT 1 TERMINATOR / POTHEAD E2 NORMAL STATUS OF SWITCHES OR CONTACTS IS
G1. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT l 0 WALL/CEILING MOUNTED THE SHELF POSITION.
MOTOR
SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. THE INSTALLATION OF ALL M
4 O JUNCTION BOX MOTOR HEATER MOTOR HEATER. E3 NUMBERS AND LETTERS IDENTIFY DEVICE.. 4
EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL SPLICE, TERMINATION
CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE DISCONNECT SWITCH (D THERMOSTAT, WALL MOUNTED
CODES. T
COMBINATION MOTOR STARTER AND � WALL TELEPHONE OUTLET T 2 MOTOR STARTER. NUMBER INDICATES NEMA SIZE -° 0- ° 1 ° CIRCUIT BREAKER,
02. THIS IS A GENERALIZED LEGEND SHEET. THIS CONTRACT MAY NOT USE ALL INFORMATION SHOWN. DISCONNECT SWITCH 1-POLE / 3-POLE
F❑ FIRE ALARM PULL STATION ° °
G3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF
;
PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO S MS MANUAL MOTOR STARTER T CAPACITOR - KVAR INDICATED o
PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE g FIRE ALARM FLASHING LIGHT
. ❑i CONTROL STATION -�-- GROUND .CONNECTION
ENGINEER
3 FIRE ALARM HORN AFD AFD - ADJUSTABLE FREQUENCY DRIVE - 3
G4. INFORMATION SHOWN MAY NOT BE ALL INCLUSIVE. SEE ALSO ANSI C37.2, Y1.1, Y32.2, AND Y32.9. --�- EQUIPMENT MOUNTING STAND F SS SOLID STATE STARTER CONTACT,
G5. VERIFY ALL COLOR REQUIREMENTS BEFORE ORDERING MATERIALS. NORMALLY OPEN / CLOSED
Q GROUND ROD AND BOX HB BELL.
W=2953125
® INSTRUMENT 6AFDBUZZER OR SS BUS STAB ON MCC; CORD & PLUG
PLAN NOTES: El ❑ ELECTRIC HANDHOLE / *S 5 WITH BYPASS CONTACTOR,
CONNECTION FOR MOTORS
P1. CONDUIT SIZE AND FILL SHALL BE AS INDICATED. WHERE NO SIZE IS SHOWN, THE CONDUIT SHALL EHH SHH SIGNAL HANDHOLE 0 HEAT DETECTOR, CEILING MTD 5 CONTACTOR NEMA SIZE AS INDICATED
BE SIZED IN ACCORDANCE WITH THE EDITION OF THE NATIONAL ELECTRICAL CODE ADOPTED BY THE �C� THERMAL OVERLOAD
sEcrloN � SMOKE DETECTOR, .CEILING. MTD
2 AUTHORITY HAVING CODE ENFORCEMENT JURISDICTION. PROVIDE 3/16 INCH NYLON PULL ROPE IN DESIGNATION 2
EACH EMPTY CONDUIT. PLUG OR CAP EMPTY CONDUITS. SECTION A 6 BUZZER g BELL HORN
P2. LOWER CASE LETTERS ADJACENT TO A SWITCH OR LIGHT FIXTURE INDICATE A SWITCHED CIRCUIT. E3Es EOL END OF LINE RESISTOR CALLOUT INDICATING CONDUIT
"C" SHEET SECTION CUT ON SHEET SECTION DRAWN ON 1 QO PER SCHEDULE
FOR 4 LAMP. FLUORESCENT FIXTURES WIRED IN PAIRS WITHIN EACH FIXTURE, THE a SWITCH FACP FIRE ALARM- CONTROL PANEL
CONTROLS THE OUTER LAMPS AND THE "b" SWITCH CONTROLS THE INNER LAMPS; WIRE 3 LAMP DETAIL
DESIGNATION RECORD DRAWING
FIXTURES SIMILARLY. DETAIL SACP SECURITY ALARM CONTROL PANEL - - CALLOUT INDICATING EXISTINGCONDUIT These Record Drawings have been prepared based on information provided
PER SCHEDULE by the contractor and others. Kennedy/Jenks Consultants has not verified the
P3. NUMBER OF CIRCLES REPRESENT THE NUMBER OF CONDUITS IN THE ENCASEMENT. 3E6 accuracy or completeness of information provided to them and does not
SHEET DETAIL DRAWN ON warrant the accuracy or completeness of these Record Drawings. Users of
SHEET DETAIL LOCATED ON these Record Drawings assume all risk of loss resulting from their use.
SURVEYED: SCALE: NONE
1 DESIGNED: WL VERTICAL:NAVD 1988 CITY OF RENTON DATE: 1
DEC 2005
ECONOMIC AND ENGINEERING Planning/Building/Public Works Dept.
DRAWN: WL ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks PROJECT No.
CHECKED: TIW AT FULL SCALE DATUM COn$U�tConsultantsSERVICES, INC. 10900 NE 4th STREET, SUITE 1110 MAPLEWOOD REVISION No.
3-01-358
APPROVED: WATER TREATMENT AND GOLF COURSE IMPROVEMENTS _
32001 32nd Avenue South, Suite 100 BELLEVUE, WASHINGTON 98005
IF NOT ONE INCH Federal. Way, Washington 98001 sHT No.
RECORD DRAWING 12/05 SCALE ACCORDINGLY PORTLAND, OR /BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA ELECTRICAL ABBREVIATIONS
..
N0. REVISION BY DATE APPR AND SYMBOLSDWG No. E 1 R
A B C D E E G " ' `� K L M I ftb N IWI-29513AAI
SENSING SWITCHES
CLOSE ON
SENSED
VARIABLE
RISING
FALLING
'-�f
0-0
FLOW
WT
LEVEL
C"Z_
T
PRESSURE
°
7
TEMPERATURE
LIMIT SWITCHES
CLOSE ON REACHING LIMIT
0-:Z3'5
CLOSE ON LEAVING
LIMIT
TIMED CONTACTS
SYMBOL
NORMAL
OPEN TO
CLOSED
CLOSED TO
OPEN
OPEN
DELAYED
INSTANTANEOUS
CLOSED
INSTANTANEOUS
DELAYED
OPEN
INSTANTANEOUS
DELAYED
*a
CLOSED
DELAYED
INSTANTANEOUS