Loading...
HomeMy WebLinkAboutWTR2702953.120A co LO 0 N I 8 7 6 B C D E F G H I J K L M N 0 P r M T H IN A - � - A C L t J I I SEE DWG E 4 EH-3a4 1 - 0II -� 132 LP"C 1 " LP" C, AC-601 B CD-305 � M MCC-3 SEF 174 - E3 E16 ; C-2,4 30A RATED WW 'B'-4ELEC ROOM 172 1 ' 176 17 5 C 9 O C-39 M E5 E18 ; ; C-1,3 [SAC P _ EF-303 3/4 C-3# 12, 1 # 12 GND 3/4 C-3# 12, 1 #12 GND 3/4 C-3# 12, 1 # 12 GND 30A RATED A/C DISCONNECT ;TYP) (TYP) (TYP) ; PROVIDE PAD -LOCKABLE 9 V-454 V-453 V-452 SEE 4 ; DOOR (DP1-13,15,17) (DP 1-7,9,1 1) (DP1-1,3,5) CD-304 M (TYP 2)S5E °CIO n_ [Do CONTROLROOM HORIZONTAL°� V-457 V-456 V-455 M M AIR SCOUR ; ,- X AC-601A (DP1-31,33,35) (DPI-25,27,29) (DP1-19,21,23) I I� E5 E16 W 0 SUPPLIER � ;� � V-483 V-482 V-481 (DP3-32,34,36) (DP3-26,28,30) (DP3-20,22,24) B-361 B-362 ' V-463 V-462 V-461 171 169 C-7 254 (DP1-26,28,30) (DP1-20,22,24) (DP I-14,16,18) EF-302 193 8 V-460 V-459 V-458 r H-303 131 BLOWER ROOM 194 CP-2 (DP1-8,10,12) (DP1-2,4,6) (DP1-37,39,41) V-466 V-465 V 464 _ RTU (DP3-1,3,5) (DP 1-38,40,42) (D�-32,34,36) FIT-413 FIT-412 FIT-41 1 (C-16) (C-14) (C-12) 3/4 "C-2It 1 # 14 GND 3/4"C-2# 14, 1 # 14 GND 3/4"C-2# 14 1 # 14 GND GS-413 GS-412 GS-411 263 7 v � WIRING DIAGRAM OF GS FILTERS 1 SUPPORTED BY U—CHANNEL TYPICAL CONDUITS RUN AT +1 1,-0„ E4 E5 C-20 HW SCALE. NONE FUME HOOD, @ 7 -b - - J Ln EF-601 �i WW C' 117 6 3j4"C-3#12, 1#12 GND VENTURI (TYP) 3/4 C-3#12, 1 #12 GND 3/4 C-3#12, 1 #12 GND 6EDUCTOR PUMP (TYP) (TYP) 1 18 P-331 V-433 Z-?--\ V-422 V-421 J (DP2-37,39,41) (DP2-26,28,30) (DP2-20,22,24) m 112 V-423 V-413 V-412 PUMP ROOM DP2-32,34,36 (DP2-7,9,1 1) (DP2-1,3,5) C (DRY LOCATION) �- ( M CD-301 Q 5 V-414 - V-416 V-415 5 DP2-25 27 29 DP2-19 21 23 P-303 rr) 165 C-5 167 (DP2-13,15,17) ( ) ( ) CD-303 M) V-417 V-419 V-418 1 168 (DP2-31,33,35) (DP2-8,10,12) (DP2-2,4,6) V-420 FIT-402 FIT-401 o (DP2-14,16,18) (C 1-3) (C-15) N FIT-403 3/4"C-2#14, 1 #14 GND 3/4"C-2#14, 1 #14 GND 11 1 C N 2953129 (G 1-5) Q 4 3/4"C-2#14, 1 #14 GND 4 P-302 o GAC-403 GAC-402 GAC-401 0 WIRING DIAGRAM OF GAC FILTERS 2 C-10 153 Q SCALE: NONE E4 E5 _-- J J 3 110 rY © FIT-311 Ln Uj 3 , 182 3 WW B 3 0 h J J nN-301 ( "'o — _ , n 3 „ ► ° `> 4 C-2 14 1 14 GND 3/4 C-3#12, 1 #12 GND 3/4 C-3#12, 1 #12 GND 3/4 C-3#12, 1 #12 GND - rt,/ # # 0 FIT-219 FIT-210 FIT -217 (TYP) (TYP) (TYP) SEE 4 � J Cn TYP 2 FIT -406 V-467 V-424 V-434 - ( ) E5 E17 o (C1-1) (DP3-7,9,1 1) (DP3-2,4,6) (DP2-38,40,42) VERTICAL 1 M o FIT-416 V-468 V-425 E5 E16 w 2 (C-18) (DP3-13,15,17) (DP3-8,10,12) EF-30 2 i V-469 V-426 130 129 6 (DP3-19,21,23) (DP3-14,16,18) WIRING DIAGRAM 3 EH-302 o t RECORD DRAWING Q These Record Drawings hove been prepared based on information provided o SCALE. NONE E4 E5 2 4 8 1 2 by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not » > » warrant the accuracy or completeness of these Record Drawings. Users of i 1 /4 =1 -0 these Record Drawings assume all risk. of loss resulting from their use. CD SURVEYED: SCALE: 1 4"=1 '_O' LIS r..M,-%DATE: 1 CITY OF RENTON DEC 2005 DESIGNED: TEK VERTICAL: NAVD 1988 r"� Plannin Buildin Public Works Dept. � ECONOMIC AND ENGINEERING - g/ g/ p i DRAWN: WIL ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks PROJECT NO. w SERVICES, INC. 3-01-358 J CHECKED: TIW Consultants10900 NE 4th STREETMAPLEWOOD AT FULL SCALE , SUITE 1110 REVISION NO. Q APPROVED: 32001 32nd Avenue South Suite 100 WATER TREATMENT AND GOLF COURSE IMPROVEMENTS - (1 DATUM BELLEVUE, WASHINGTON 98005 IF NOT ONE INCH Federal Way, Washington 98001 SHT NO. Y — RECORD DRAWING 12/05 SCALE ACCORDINGLY PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA BUILDING POWER PLAN NO. 2 w a DWG N0. Z N0. REVISION BY DATE APPR E5R A D E F G H K L I M �r,3 SCANEG OCT272I�16 IWI-121915131AIA