Loading...
HomeMy WebLinkAboutWTR2702953.131A B C D E F IG N K M N 0 P INITIAL GRADE (NOTE 1) LO N I 00 -� COMPACTED FILL 1 C N i-- -- F WARNING TAPE F-- Q 2„ POWER CONDUIT CONCRETE ENCASEMENT 9 3„ UNDER ROAD, NATIVE 9 FILL ELSEWHERE 7-1/2" NOTE: 1. SEE CIVIL SHEETS FOR PAVING REQUIREMENTS. W=2953134 g 8 D U CTBAN K SECTION 2 SCALE: NONE E3 E16 PLASTIC CIRCUIT TAG FINISHED GRADE CAP (THREADED TYPE) CABLE RACK AS REQUIRED PERMANENTLY MARKED PRECAST SLAB (NOTE 4) NOTES: REFLECTING TAPE .TRAFFIC COVER AS REQUIRED WITH •CIRCUIT NAME ,��0 ACCESS COVER 1. PRECAST SLAB SHALL BE SIMILAR TO THE REQUIREMENTS (3 WIDE) % - I OF PUGET SOUND ENERGY (PSE). z 6" 0 POST - SCH 40 z 7 FINISHED GRADE `�'1 :2 GRS STANDARD ------------ ------- --- 2. PROVIDE GROUND RODS AND CLAMPS. SEE CONDUIT SCHEDULE 7 PLASTIC CABLE -------- ---------- TIE EVERY 6" (TYP)' I � EXTENSION RING �� 7 7,\ ...,_ ,.,' ' FOR GND WIRE. FILL WITH CONC00 1 AS REQUIRED CABLE RACK INSULATOR CONDUIT f 3. MASTIC SEALANT IS REQUIRED AT JOINTS. LOCK 5/8" 0 GRS EYE BOLT, BUSHING (TYP) 4. TOP SURFACE OF PRECAST SLAB SHALL BE SET THREE INCHES WELDED TO POST (TYP 2) (3 PER HOOK) AS REQUIRED PRECAST BOX ABOVE FINISHED GRADE. Eo I I _ 10" CABLE HOOK CONDUIT (NUMBER O - AS REQUIRED I O SECTION 5." PRECAST BOX MEASURES APPROXIMATELY 7'W x 7'L x 3'-6"D � - I I --- -�'—�------� ;------ 6 AS REQUIRED2 PER ) ) 1 O O (NOTE 5) PULLING I I CONIC BASE 6 SEErf�'�1 DEVICES (TYP) ► 0 1 1 7„0 POST-SCH 4 E16 E17 6" DIA SUMP z I I GRS STANDARD 3/4 CRUSHED O I I MACHINE BOL N 18" DEEP OF 3/4" PEA GRAVEL ROCK O N GROUND ROD CONDUIT TERMINATORS - �, L -J j 3/4 R MIN„ SI E, 3 4"x 8' COPPERCLAD STEEL GA V OSTEEL / 1 CAPPED PVC CONDUIT EHH-1 & 3 ONLY NOTE 2 5 18 " 0 18 " 0 5 PRECAST CONCRETE GROUND RODS 2 REQUIRED TYPICAL CONCRETE PAD & VAULT FOR 3 PHASE HANDHOLE INSTALLATION 6 3/4"x 8' COPPERCLAD STEEL 2000KVA TRANSFORMER INSTALLATION 7 8 SCALE: NONE E6 REMOVABLE & NON —REMOVABLE POST (NOTE 2) SCALE: NONE E3 E16 SCALE: NONE E3 E16 3 E1 ANGLE BRACKET 8„ x 8„ WIREWAY TOP RUNG (2 PER SECTION) CONDUIT LIQUID TIGHT FLEXIBLE 3/8" DIA BOLTS MIN „ „ I I ANCHOR TO WALL 4 3/8 0 ROD PROVIDED AS REQUIRED TO 8 x 8 WIREWAY � , I l CONDUIT SLOPE TO MIDDLE 4 SUPPORT " U-CHANNEL AT 12' INTERVALS - DISCONNECT SWITCHFPROVIDE INTERNAL GROUND .SLOTTED BASE U-CHANNEL BARRIER ; I (WHERE REQUIRED) EQUIPMENT 1-5/8"x 1-58"x 1 12GAGE i / AIR SPACE. , BARRIER I I I , 8" . WITH 7/16 x 3 SLOTTED I , EQUIPMENT GROUNDING HOLE ON 4" CENTERS I i I-�; CONDUCTOR SIZE (SUPERSTRUT A-1400S) j I_,; I ili PER NEC OR CONDUIT n� iI� C 4x5.4 STEEL HORIZONTAL SCHEDULE AS HANGER i i ill CHANNEL STANCHION APPLICABLE (TYP) 3 ASSEMBLY I*I l il' PIPE 3 j GUSSET BRACKET I it i RACKS GROUND BUS it I it INSULATED ill SUPPORT AT EACH VERTICAL I ili GROUNDING BUSHING BRACKET - I SECTIONS OF PIPE RACK I ili o FLUORESCENT LIGHT FIXTURE I GUSSET BRACKET 3/8"0 BOLT WALL AND/OR I ' 4 PER SECTION SUPPLEMENTARY SUPPORT AT EVERY 5'-0" ( ) CEILING TRUSS I i LIQUID TIGHT FLEXIBLE CONDUIT CONCRETE PAD _ I � 2 INSULATION � I''77 �I��1NG 2 INSULATION #1 AWG MIN (TYP) CONDUIT REBAR 2 2 —'-- D ETAI L 1 SCALE: NONE E4 E5 VERTICAL E16 RECORD DRAWING M C 0 N N ECTI 0 N DETAIL These Record Drawings have been prepared based on information provided FIXTURE MOUNTING DETAIL 9 WIREWAY MOUNTING DETAIL _1 WIREWAY MOUNTING DETAIL 1 0TOR 1 by the contractor and others. Kennedy/Jenks Consultants has not verified the SCALE: NONE 7 E16 SCALE: NONE E4 E16 SCALE: NONE SCALE: NONE accuracy or completeness of information provided to them and does not E E4 E8 E16 E5 E4 E16 warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. SURVEYED: SCALE: NONE s� CITY OF RENTON 1 DESIGNED:.. TEK VERTICAL: NAVD 1988 � DATE: DEC 2005 1 Planning/Building/Public Works De ECONOMIC AND ENGINEERINGt. P DRAWN: WIL ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks PROJECT No. SERVICES, INC. 3-01-358 CHECKED: TIW Consultants MAPLEWOOD AT FULL SCALE 10900 NE 4th STREET, SUITE 1110 REVISION No. APPROVED: WATER TREATMENT AND GOLF COURSE IMPROVEMENTS - 32001 32nd Avenue South, Suite 100 BELLEVUE, WASHINGTON 98005 IF NOT ONE INCH DATUM Federal Way, Washington 98001 A RECORD DRAWING WL 12/05 PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA ELECTRICAL DETAILS NO. 1 SHT NO. SCALE ACCORDINGLY NO. REVISION BY DATE APPR DWG No. E16R A B C D E, F G H K M N W