HomeMy WebLinkAboutWTR2702953.14C0
LO
M
N
I`
N
'i
9
8
7
6
5
4
3
21
low
POC 9A
w N
f
w
EXISTING 565 ZONE �
EXISTING 590 ZONE
EXISTING 196 ZONE —
EXISTING
SUPPLY
Do
O
�!
CJ
Ili
2 RECORD DRAWINGS
1 ISSUED FOR CONSTRUCTION
NO. REVISION
A B
CVICTIKH"I 1 C)C, 7nKIC
SURVEYED: —
DESIGNED: J.E.
DRAWN: R. B.
CHECKED: G.P.
APPROVED: —
RB 1/06 GP
RB 10 0 GP
BY DATE APPR
C ID
89
SCALE: AS SHOWN
VERTICAL: NAVD 1988
ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks
AT FULL SCALE Consultants
DATUM 32001 32nd Ave. S., Suite 100
IF NOT ONE INCH Federal Way, Washington 98001
SCALE ACCORDINGLY
E
f=
G
H
vU
u t '97 96
ECONOMIC AND ENGINEERING
SERVICES, INC.
tt 10900 NE 4TH STREET, SUITE 1110
BELLEVUE, WASHINGTON 98004
PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA
0
J
K
GENERAL NOTES:
1. UNLESS NOTED OTHERWISE, ALL WATER PIPING SHALL BE CL 52 DI, 10
WSDOT 9-30.1(1). SIZE AS SHOWN.
2. UNLESS NOTED OTHERWISE, ALL PUSH —ON JOINTS SHALL BE FULLY
RESTRAINED WITH "FIELD LOCK" GASKETS OR EQUAL.
3. UNLESS NOTED OTHERWISE, ALL FITTINGS SHALL BE FULLY
RESTRAINED W/SERIES 1100 "MEG—LUGS" BY EBAA IRON OR EQUAL.
ANY "MEGA -LUG" RESTRAINED FITTINGS ENCASED IN CONCRETE 9
SHALL BE COMPLETLY WRAPPED IN PLASTIC PRIOR TO ENCASEMENT.
4. UNLESS NOTED OTHERWISE, ALL FITTINGS SHALL BE 250psi RATED
AWWA C110 OR C153, WSDOT 9-30.2(1).
NOTES:
1O REF. WELL 11 AND 17 SUPPLY PLAN SHEET C33
8
O REF. WELL 12 SUPPLY AND BCW PLAN SHEET C34
O REF. LOCAL WATERMAIN UPGRADES SHEET C35
O REF. 565/196 ZONE PRV C36 AND C39
0 REF. EXISTING OVERFLOW MODIFICATIONS C37
O EXISTING BUILDING TIE—IN REF M21, M22 7
7O NEW BUILDING TIE—IN, REF. M14
_Y
POINT OF CONNECTION REF. POINT ID.
EXISTING POC X NEW 6
E N
W=2953AF
5
4
SEE ALSO SHT. C22 FOR UTILITY AS —BUILT
INFORMATION.
SEE ALSO SHT. C32 FOR UTILITY AS —BUILT
INFORMATION.
3
SEE ALSO SHT. C35 FOR UTILITY AS —BUILT
INFORMATION.
7
CONSTRUCTION RECORD DRAWING NOTICE
These record drawings have been prepared based upon 2
information contained in addenda, change orders, or
other available construction information, and information
provided by the Contractor, and by others. HDR has not
verified the accuracy or completeness of the information
1 provided to it and does not warrant the accuracy or
completeness of these record drawings. Users of this
information shall be solely responsible to verify any and
all information represented herein prior to any such use
of the information.
�- CITY OF RENTON
� DATE: OCTOBER, 2003 1
Planning/Building/Public Works Dept.
MAPLEWOOD PROJECT N0. 3-01-358
WATER TREATMENT AND GOLF COURSE IMPROVEMENTS REVISION NO. 2
WATER PIPING OVERVIEW SHT No.
DWG NO. C32
L M N JW-91513 Al A