Loading...
HomeMy WebLinkAboutWTR2702953.79C'') LO O') N N I 0 0 • 7 A 5 0 3 2 3 / U C r U / N ca 0 0 0 U of o, .3 � 0 0 Q U I 0 PO M 0 w z J 0 0 1'-0" 3/8"=1'-C B C D E F G H I J K G ,,,MATC'I-II IMF FnR rONTINI IATInN OFF nRAWINC; M1 � 2 RECORD DRAWINGS 1 CHANGE PER ADDENDA 1 ISSUED FOR CONSTRUCTION NO. REVISION A B SURVEYED: — DESIGNED: AF DRAWN: RB CHECKED: GP RB 1 /06 GP APPROVED: — RB 10/03 AF RB 0 0 AF BY DATE APPR C D \it 11 M15 M15 SCALE: 3 8"=1'-0 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY E VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM Kennedy/Jenks Consultants 32001 32nd Ave. S., Suite 100 Federal Way, Washington 98001 ECONOMIC AND ENGINEERING SERVICES, INC. 10900 NE 4TH STREET, SUITE 1110 BELLEVUE, WASHINGTON 98004 PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA J K a I I 0 GENERAL NOTES 1 . CONTRACTOR SHALL CONFORM TO PIPE ROUTING & ARRANGEMENT AS CLOSELY AS 10 POSSIBLE. NOT ALL PIPING, VALVES, FITTINGS AND ACCESSORIES ARE SHOWN. PROVIDE ALL PIPE, VALVES AND ACCESSORIES AS SHOWN ON INSTRUMENTATION DRAWINGS EVEN THOUGH NOT SHOWN ON THIS DRAWING. 12. AS SHOWN ON DRAWING M2 ALL MAJOR PROCESS PIPING IN THE FILTRATION BUILDING SHALL BE BLACK STEEL PIPE. DRAWINGS DEPICT FLANGES. HOWEVER, EXCEPT AS NOTED OTHERWISE BELOW, GROOVED COUPLINGS ARE ACCEPTABLE. IF GROOVED COUPLINGS ARE USED, GROOVES SHALL BE CUT, NOT ROLLED, AND MINIMUM PIPE THICKNESS SHALL BE 3/8 ". 9 3. ALL VALVES SHALL BE FULL FLANGED. NO GROOVED JOINTS OR WAFER STYLE VALVES SHALL BE PROVIDED. 4. DISASSEMBLY JOINTS OR FLANGE COUPLING ADAPTORS WITH LIMIT RODS MAY BE ADDED WHERE DESIRED TO FACILITATE PIPING ASSEMBLY. 5. CONTRACTOR SHALL PROVIDE ANY AND ALL VALVED VENTS AT HIGH POINTS AND OTHER LOCATIONS AND ANY AND ALL VALVED DRAINS AT LOW POINTS AND OTHER LOCATIONS IN THE PIPING SYSTEMS THAT ARE NECESSARY TO SUCCESSFULLY HYDROSTATICALLY TEST THE B PIPES AND LINES. 6. PIPE SUPPORTS ARE SHOWN ON M29, S12 AND S13. 7. FOR CONCRETE PUMP PAD, SEE DETAIL ON SHEET S1 FOR TYPICAL EQUIPMENT PAD REINFORCING. SIZE TO PROVIDE 1 /4" ° CLEARANCE BETWEEN e STEEL CAP AND PEDESTAL. a d e ° A x f=2953FO �— 1 /8" GALVANIZED STEEL CAP OVER PUMP PEDESTAL. e 6" a SEAL SPACE BETWEEN CAP AND PEDESTAL WITH A MASTIC SEALANT. e° d e e .• a •. ° n• SECTION/1', SCALE: NTS — PUMP PEDESTAL CAP CITY OF RENTON i° Planning/Building/Public Works Dept KEY PLAN CONSTRUCTION RECORD DRAWING NOTICE 7 I 5 0 3 These record drawings have been prepared based upon 2 information contained in addenda, change orders, or other available construction information, and information provided by the Contractor, and by others. HDR has not verified the accuracy or completeness of the information provided to it and does not warrant the accuracy or completeness of these record drawings. Users of this information shall be solely responsible to verify any and all information represented herein prior to any such use of the information. MAPLEWOOD WATER TREATMENT AND GOLF COURSE IMPROVEMENTS PARTIAL PLAN @ RAW WATER MANIFOLD AND LOW LIFT PUMP ROOM L M N PROJECT NO. REVISION NO. SHT NO. DWG NO. OCTOBER, 2003 3-01-358 2 MONEMENNA