HomeMy WebLinkAboutWTR2702953.83i
I P
A B C ,f
EXISTING WINDOW
co INSTALL BFP _ Q 48 AFF
LC) �-----�--- ----� ,
0') `—V--- 79-3--BF---P --7- -9---2 �--- 3/4 BACKFLOW PREVENTER
1— N a 0 C L R ET U R Nw TO DAY TANK
C
_ ,
V 791
N �---- ----� Al
784
_
�— -- --- 0 _
—� V - --- ---
v 781 v 785 --- --- WATER S U P P LY ROOM
�----- ----� V— 7 8 7 - --- --- —�,
V-78
�- ---� V— 7 8 8 ; --- ---
BFP-782--- ----� -
�---- ----� V-790 ;
1 BACKFLOW PROVIDE
_ - VIDE
C
PREVENTER 4—WAY BRACE
i ALARM FLOW SWITCH...
9
9 _-
NaOCI TRANSFER ,,
2 PI ft-
'1/2 —SA ( 13) PLUS SPARE (2 TOTAL)
_ 1 r
TREATED WATER 590 ZONE 2„ ANGLE VALVE
1 „
V-794
s
INSPECTORS 1 /4
TEST PLUG
1 2
ff
—SA 14 PLUS SPARE 2 TOTAL _
V 780
65 ZONE
_-- TREATED WATER 5
�----- � T R E E
2
f
8 ,
� PI PI
R _
EXIST.DOO V 780A ,
`---- ----� TYP.(4)PLCS .
1 2 PO LY
/ a
BACKBOARD
i
1 - DOUBLE CHECK DETECTOR VALVE
NC NC 1 PREVENTER. INSTALL
BACKFLOW
. SPEC. 15330
N� NC
VERTICALLY SEE
5
LUJ U
7
r . _ JMP-75_1]*MP-752 MP-753 MP-75 2-NaOCL OVERFLOW
1 TO HYPOCHLORITE
i V-795 ; 0 _
1 STORAGE TANKS PLUS SPARE 4 x2 1 /2 RE
f
f�
HOSE
N ff 2 DRAIN
1 1 —NaOCL TRANSFER TO OUTSIDE
BIBB _ LINE PLUS SPARE EXISTING 4„ RISER PIPE
HYPOCHLORITE METERING PUMPS
_KT�
SEE DETAIL
3 /
3 4 NaOCL TO —
NEW TREATMENT
BUILDING PLUS SPARE
1—Na OCL FROM
DAY TANK —\-(N) POC 14
-' II
(E)
PIPE PENETRATION
POC 12 N
TYPE X 1, SHT. M30
(E)
DETAIL
51/2"-CARRIER5 ��117
1
1
SC ALE: NTS
WATER FR
OM 565 ZONE
SEE SECTION- R ON DWG. M24
_\--1/2"—NoOCL
TO 4
RECHL O R I NATI O N SYST M
E SEE SECTION R ON
DW
G. M24 _
NOTES
/ 1 PR ( �I OVIDE ALL PIPING, VALVES AND ACCESSORIES AS SHOWN 0N SHEETS 18
J
6 8c 19
4
4
2 .PROVIDE CALIBRATION CHAMBERS WITH.. SCREWED TOP CLOSURES.
3 NEW OPENING IN WALL BETWEEN HYPOCHLORITE FEE AND WATER
SUPPLY
SECTION
M
3��7
ROOMS.
,, GENERAL NOTES .-
SCALE: 4 =1 —0
1. CONTRACTOR SHALL CONFORM lO PIPE ROUTING & ARRANGEMENT AS 4 ROUTE NEW RECHLORINATION PIPING TO EXISTING CHLORINATION PIPING AND
CLOSELY AS POSSIBLE. NOT ALL PIPING VALVES, FITTINGS AND CONN
ECT WHERE SHOWN.
V
ACCESSORIES ARE SHOWN. PROVIDE ALL PIPE, VALVES AND ACCESSORIES
c T
SHOWN ON INSTRUMENTATION DRAWINGS EVEN THOUGH NOT SHOWN ON 5 METERING PUMP SUPPORT SHELF. SEE DETAIL AIL 2, SHT. M 17
AS S �
3
THIS DRAWING.
6 CHEMICAL PIPING- CONTAINMENT CONDUIT RUNNING TO HYPOCHLORITE
VAULT 2. NOT USE. STORAGE `AUL. AND TO FILTRATION BUILDING.
3. NOT
USED.
4. DISASSEMBLY JOINTS OR FLANGE COUPLING ADAPTORS WITH LIMIT RODS
MAY BE ADDED WHERE DESIRED TO FACILITATE PIPING
ASSEMBLY.
CONSTRUCTION RECORD DRAWING NOTICE
r ared based upon
i These record drawings have been pep
VALVED VENTS AT HIGH. POINTS2
5. CONTRACTOR SHALL PROVIDE ANY AND ALL AL
3 2 n contained in addenda change orders or
information co to g ,
AND OTHER LOCATIONS AND ANY AND ALL VALVED DRAINS AT LOW POINTS
other available construction information, and information
1-11 AND OTHER LOCATIONS IN THE PIPING SYSTEMS THAT. ARE NECESSARY TOW2953F4 provided b she .Contractor, and b others. HDR has .not
75
P Y Y
verified the accuracy SUCESSFULLY HYDROSTATICALLY .TEST. THE PIPES AND LINES. Y or completeness of the information
provided to it and does not warrant the accuracy Y or
completeness of these record drawings. Users of this
information shall be solely responsible to verify any and
all information represented herein prior to an such use
o
P P Y
o - _
of the information.
w -
, _ ��
— 4 —1 — 0 e
SURVEYED:SCALE. 3
�-- DATE.
CITY OF RENTON
_ OCTOBER, 2003
i DESIGNED: AF V 1 f.�
o DES VERTICAL. NAVD 988 — Planning/Building/Public Works De t.
i
ECONOMIC AND ENGINEERINGP
ONE INCH T PROJECT NO.
DRAWN. - RB HORIZON IAL: NAD 1983/1991 K nn i k
SERVICES, INC.
3-01-358
, CHECKED. GP - MAPLEWOOD
AT FULL SCALE
s pant
10900 NE 4TH STREET SUITE 1110 E REVISION No.
� WATER TREATMENT AND GOLF COURSE IMPROVEMENTS
2 RECORD DRAWINGS RB 1/06 GP APPROVED. —
32001 32nd Ave. S., Suite 100 2
N
DATUM.-
BELLEVUE, WASHINGTON 98004
o RB 10. 03 AF
CHANGE.: PER ADDENDA
1 /
Wa Washington 98001
.. IF NOT ONE INCH Federal,
Y 9 JHT No.
PORTLAND OR BELLEVUE WA Kt:. WA OLYMPIA, WA
SE
CTION M
RB 10 0 AF / _ //
1 ISSUED FOR CONSTRUCTION / SCALE ACCORDINGLY
.THROUGH HYPOCHLORITE FEED AND HATER SUPPL
Y ROOMS DWG NO.
8
w
N0.
REVISION BY DATE APPR M1
C D E2953A
F G H I K
L M
N
A B C