Loading...
HomeMy WebLinkAboutWTR2702953.93co C) CV C\1 0 5 3 0 L B C I D E I F G I H -------------------- I---------------- ----------7---------I I r_'F)__An77fFi -An-, n 3 RECORD DRAWINGS 2 CLARIFICATION 1 CHANGE PER ADDENDUM 01 ISSUED FOR CONSTRUCTION NO. REVISION A B SURVEYED: DESIGNED: R. RAY DRAWN: L. MARX RB 1 /06 GP CHECKED: J. FORAY LMM 10/03 MDL APPROVED: LMM 8/22/03 M D L LMM 10/03 MDL BY DATE APPR C D SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY E VERTICAL: NAVID 1988 HORIZONTAL: NAD 1983/1991 DATU M Kennedy/Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, Washington 98001 G H J 3 IGERANT PIPING- ) AA i I i L DETAIL 1 SCALE: 3/8"=V-0" M26 SECTION A SCALE: 3/8"=V-0" M26 ECONOMIC AND ENGINEERING SERVICES, INC. 10900 NE 4th STREET, SUITE 1110 (E) BELLEVUE, WASHINGTON 98005 PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA J L M N 0 P NOTES: REFERIGENT PIPE AS RECOMMENDED BY THE EQUIPMENT MANUFACTURER. 10 2. SUPPORT DUCTS PER SPECIFICATION SECTION 15800. DUCT SUPPORT SIMILAR TO PS3 SUPPORT ON DRAWING S13. SET FAN 9 FEET ABOVE FINISHED FLOOR, SUPPORT FROM WALL AT 2 LOCATIONS EACH FAN, SPREAD THE LOAD OF EACH FAN OVER TWO JOISTS. 4. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ROOFTOP VENTILATORS. PROVIDE 16x8 BRICK LOUVER FOR ALL SIDEWALL 9 DUCT PENETRATIONS (INCLUDING DEHUMIDIFIERS) 6. PROVIDE ROOF VENTILATORS AND GABLE VENT x20 CER LOUVERS. SEE ARCHITECTURAL DRAWINGS A3 AND A4 FOR LOCATIONS AND DETAILS. Al /2 7. FOR HVAC DEVICE SYMBOLS SEE HVAC LEGEND, SHEET M25. K10 CER ri inn�n�- rer.i rnn�i REFRIGERANT PIPING SECTION s SCALE: 3/8"=V-0" M26 W=2953FE 1 ' 0 1 ' 2' 3' 4' 5' 6' 7' SCALE: 3/8"=1'-0 4' 0 4' 8' 12' 16' 20' SCALE: 1 /8"=1'-0" CONSTRUCTION RECORD DRAWING NOTICE These record drawings have been prepared based upon information contained in addenda, change orders, or other available construction information, and information provided by the Contractor, and by others. HDR has not verified the accuracy or completeness of the information provided to it and does not warrant the accuracy or completeness of these record drawings. Users of this information shall be solely responsible to verify any and all information represented herein prior to any such use of the information. - CITY OF RENTON i° Planning/Building/Public Works Dept. MAPLEWOOD WATER TREATMENT AND GOLF COURSE IMPROVEMENTS FILTRATION BUILDING HVAC PLAN L M N on • 0 5 3 2 DATE: OCT 2003 1 PROJECT No. 3-01-358 REVISION NO. 013 SHT NO. DWG No. M26 WI-12 5 AA