Loading...
HomeMy WebLinkAboutSWP2702988.5c E U 01 i N N Q pl d 3 00 00 N 04 I IL 41 z w J L CID l 0) — �— N 30' N i U) 00 D ,N N k � 0 N S c� n v I CsI SD CD O U D r�- m I D � A i v I j II r D z SD \C / SSMH (NOT FOUND) RIM=40.88± IE 8" N=36.5t BLDG. # 724 2 STORY MASONARY FIN FLOOR— 41.0 W/ NO APPAIRENT BASEMENT -T- CB RIM=40.80 IE 3"PVC E/W=40.0 BLDG. # 229 & 231 2 STORY MASONARY FIN FLOOR # 231=40.9 FIN FLOOR # 229-41.1 W/ NO APPARENT BASEMENT NOTES 1. ALL MANHOLE FRAMES AND COVERS, AND CATCHBASIN FRAMES AND GRATES SHALL BE LOCKING. N01"28'20"E 2656.29' CALC. 2. CB LOCATIONS MAY BE ADJUSTED TO AVOID CONFLICTS. CURB CB'S MAY BE REVISED TO OPEN CURB FACE INLETS OR VERTICAL CURB INLETS. ALL ADJUSTMENTS REQUIRE CITY APPROVAL. WILLIAMS AVE. S* 3. WELLS AVE S, WILLIAMS AVE S, S 2ND ST. MAY HAVE 6 TO 13 INCH THICK CONC. PAVEMENT AND / OR 6 TO 9 INCHES BRICK UNDER THE ASPHALT. 4. CONTRACTOR SHALL COORDINATE WITH SEATTLE PUBLIC UTILITIES WHEN WORKING NEAR SEATTLE WATER MAIN IN S 2ND STREET. CONTACT SPU 48 HOURS BEFORE CB RIM=41.12 BEGINNING CONSTRUCTION WITHIN 20 FEET OF SEATTLE WATER MAIN FOR SPU IE 3"PVC E/W=40.3� PROVIDED INSPECTION. CONTACT LAKE YOUNGS OFFICE AT (425) 255-2242. CB RIM=40.80 SPU SHALL BE GIVEN ADVANCE WARNING PRIOR TO THE CONTRACTOR EXPOSING SPU /_IE 3"PVC E/W=40.0 SSMH RIM=41.25 WATER PIPE TO ALLOW SPU THE OPPORTUNITY TO INSPECT THE PIPES CONDITION. C CHFAN NHS=35.4 BLDG. # 225 CB RIM=41.21 CAUTION 3 STORY CONC BLD= N IE 3"PVC E=41.4 ACCESS TO FIN FLOOR 41.3 UNDERGROUND 12" HIGH PRESSURE No BASEMENT BUT soMF CAUTION ASP"A VAULT GAS MAIN UGT AND FIBER OPTIC CONDUITS, CB RIM=41.08 # 8"CONC TO SDMH UGT AT NEW 225 \ CABLE VAULTS POSSIBLY ENCASED, POTHOLE IE 3"PVC E/S=40.3 \ ALONG ENTIRE BLOCK STORM PIPE CONC. WALK 8' DEC CB-13B -.. UGP B D E�UGP -�; rI f `.EP -UGP I m 6„DEC. ❑ -- _. - - ASPHA: T BLDG# 201 2 STORY CONC, BLOCK FIN FLOOR=40.9 NO BASEMENT CB RIM=40.83 - IE 3"PVC E/S=40.0 r 0 D /1 it ! II SSMH RI ^ 40.8, , CL CH- 3.7 I POTHOLE I I / CCB O20AT I � � CB—B En � SURVEYED: SCALE: ORIGINAL SEALED 3/15/2005 HORIZONTAL, NAVID CENTRAL BUSINESS DISTRICT HORIZONTAL NAD 1983/7991 �� _ CITY O E 3/ 1 4/ 0 5 FIELDBOOK: RECORD D RAW I N G DESIGNED: 1 —20 •. ' DC BY LYS L. HORNSBY �, RENTON UTILITY REPLACEMENT PAGE: RECORD INFORMATION PROVIDED BY SURVEY DRAwN: 3 AS —BUILT: Revised CB Locations per survey, updated DWC 3-31-14 DWC DC ONE INCH X DRAWING No: 23169 AND OTHER INFORMATION PROVIDED BY CONTRACTOR elevations redraw profiles, removed old info, other 4. eanup c anges. CHECKED: Dept.STORM SEWER REPLACEMMENT D — AT FULL SCALE ' Planning/Building/Public Works IF NOT ONE INCH- N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OF: WILLIAMS AVE S 13RD TO S 2ND) 5 12 D-2988D2 f G S ❑ U T m W z m z z m J) b �C) r� > CD >�r �z CD 0 r z 0�0 D T O ❑ m ❑ p -Doc A D� Q Z