HomeMy WebLinkAboutWTR2702988.11� G ' o ZI U K m z m z m m co 0 0 D w • N �i U O af > a 3 co co N I N I a- m z W J LL 1 '-6" SQUARE CONCRETE SLAB TYPE FT - FLUSH MOUNTED TEST STATION NT` '-6" SQUARE WISH GRQF = CONCRETE SLAB 6" THICK 0.01 OHM 05 HOLLOWAY SHUNT ANODE LEAD WIRE TERMINAL #12 AWG COPPER WIRE WITH BLACK #12 AWG COPPER INSULATION WIRE WITH BLUE INSULATION CTION, ETAI L G '.'VANIC ANODE NOTE: TYPE —A INSTALL GALVANIC ANODE 1' O" BELOW PIPE INVERT ELEVATION. WIRE CONNE TYP, SEE D THIS SHEET PIPELINE TYPE FTA - FLUSH MOUNTED TEST STATION NTS ORIGINAL SEALED 3/15/2005 BY LYS L. HORNSBY 23169 1 '6" SQUARE FINISH GPA �= CONCRETE SLAB 6" THICK „iSTING NEW OR PROTECTED i UNPROTECTED PIPELINE TERMINALS PIPELINE TERMINALS I 1-#8 AND 1-#12 AWG COPPER WIRES WITH GREEN 1 #8 AND L INSU' TION AWG COPPER WIRES WITH BLUE INSULATION #12 AWG COPPER WIRE — W/ BLACK INSULATION NEW OR PROTECTED PIPELINE —� EXISTING OR UNPROTECTED PIPELINE WIRE CONNECTION, TYP, SEE DETAIL THIS SHEET INSULATING JOINT, SEE DETAIL THIS GALVANIC SHEET ANODE NOTES: 1. INSTALL ALL LST WIRES IN 1 " PVC CONDUIT WITH 24" MINIMUM BURIAL DEPTH 2. INSTALL GALVANIC ANODE 1'-O" BELOW PIPE -RT AND 1'-6" FROM EDGE OF PIPE TYPE F- FLUSH MOUNTED TEST STATI 0 N NTS THERMITE \HELD CAP, TYE' RE CONNI CTION, NOTE: TYP, SEE ENTAIL THIS SHEET 1. TWO BOND WIRE ASSEMBLES REQUIRED AT EACH 16" PIPE JOINT AND ONE ASSEMBLY ON SMALLER PIPE JOINTS. 2. PUSH ON J(­1 I, T SHOWN. BOND SIMILAR FOR FLANGED JOINT. PUSH -ON AND FLANGED JOINT BOND NITS #2 AWG INSULATED STRANDED COPPER WIRE 24" LONG FLEXIBLE OR EXPANSION COUPLING 12 AWG INSULATED STRANDED COPPER WIRE, TYP OF 2 THERMITE WELD CAI), -� THERMIT'I- WELD TYP EACH WELD, WIRE CONNECTION, OTHERS NOT SHOWN TYP, SEE DETAIL THIS SHEET NOTE: SEE SPECIFICATIONS FOR NUMBER OF BOND REQUIRED AT EACH PIPE JOINT. FLEXIBLE JOINT BOND PIPELINE ANODE WI GALVANIC PIPELINE ANODE WI GALVANIC WIRE CONNECTION, cCC ITCTAII TLJIC CLJCCT WIRE CONNECTION, C`F-F- LIF-TAII TI IIC' C'LJCCT ELEVATION NOTES: 1. ALTERNATE ANODE PLACFVENT ON OPPOSITE SIDES OF PIPE 2. LOCATE ANODES 2' fv'..INIMUM FROM OTHER UNPROTECTED PIPES. 3. INSTALL ONE ANODE ON EACH OF PIPE AND ON EACH FITTING. GALVANIC ANODE INSTALLATION ONE PIPE DIA MINIMUM, 2'0" MAXIMUM — THERMITE WELD - CAP, SEE NOTE 4, TYP FILE OR GRIND WELD AREA TO BRIGHT METAL — WIRE SIZE VARIES, TWO vVRES READ FOR TEST STA INSTALLATIONS ONLY 4- THERMITE WELD WIRE CONNECTION STEEL OR DUCTILE IRON PIPELINE NOTES: 1. COPPER SLEEVE REQUIRED FOR THERMITE WELDING OF #10 AWG AND SMALLER WIRE. 2. USE COPPER SLEEVE ON #2 AWG JOINT BONDING WIRES. 3. WELDER AND CARTRIDGE SIZE VARIES ACCORDING TO WIRE SIZE AND PIPE MATERIAL, CONSULT WELDER MANUFACTURER FOR RECOMMENDED WELDER AND CARTRIDGE. 4. COAT WELD AREA AND FILL RECESS ON THERMITE WELD CAP WITH COLD APPLIED COAL TAR MASTIC AND APPLY CAP TO WELD, WIRE CONNECTION FOR STEEL AND DUCTILE IRON PPE `J W 2988 SURVEYED: SCALE: DESIGNED: N/A RECORD DRAWING AG DRAWN: RECORD INFORMATION PROVIDED BY SURVEY AS —BUILT MAB 2/2014 CHECKED:: ONE INCH AND OTHER INFORMATION PROVIDED BY CONTRACTOR AG AT FULL SCALE IF NOT ONE INCH N 0. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM INSULATING WASHER, TYP STEEL WASHER, TYP INSULATING SLEEVE, 1 /32" SPIRAL WOUND MYLAR, LENGTH DESIGNED TO EXTEND TO NUT FACE ON EACH SIDE OF FLANGE FULL FACE INSULATING GASKET PIPELINE FLANGE, TYP NOTES: 1. ABOVE GRADE INSULATING FLANGE INSTALLATION SHOWN 2. FOR BURIED OR SUBMERGED INSULATING FLANGE INSTALLATION, DO NOT INSTALL INSULATING WASHER ON PROTECTED OR NEW SIDE OF FLANGE. 3. COAT BURIED OR SUBMERGED INSULATED FLANGES WITH COLD APPLIED COAL TAR MASTIC AFTER ASSEMBLING JOINT AND WRAP WITH A BUTYL RUBBER ADHESIVE, POI YETHYI ENL BACKED TAPE. INSULATING FLANGE N 1 `O 1 #8 AND 1 #12 AWG COPPER WIPE WITH BLUE TW INSULATION _ THERMITE WELD WIRE CONECTION (TYPICAL) 1'-6" SQUARE CONCRETE SLAB 6" THICK STEEL PIPELINES "'ISH GRAF — T___lvflNAL BLOCK 1 #8 AND 1 #12 AWG COPPER WIRE WITH WHITE TW INSULATION #12 AWG COPPER WIRE W/ BLACK INSULATION ;` E PIPE DIAMETER MIN. (TYPICAL) — NEW RENTON`` E.I_ WATER LINE NOTES: 1. INSTALL ALL TEST WIRES IN 1 " PVC CONDUIT 24" MINIMUM BURIAL DEPTH 2. INSTALL GALVANIC ANODE BETWEEN PIPELINES AT EDGE OF ETHAEOAM PAD TYPE FF - CATHODIC PROTECTION FLUSH MOUNTED TEST STATION #2 AWG STnnKir-17rn COPPER WI THHN INS ­NNECTION, vIL THIS SHEE #12 AWG STRANDED UNPROTECTED PIPE COOPER WIFE W/THHN INSULATION DRESSER STYLE 39 OR INSULATED NYLON SLED PROTEC -D PIPE FOR D.I. PIPES INSULATED FLEXIBLE COUPLING NTS DATE: CITY OF CENTRAL BUSINESS DISTRICT 3/14/05 FIELDBOOK: RENTON UTILITY REPLACEMENT DRAWING NO: Planning/Building/Public Works Dept. W-5 CATHODIC PROTECTION DETAILS SHEET: OF: 11 1 + W 29gOW6 A� o' m p o0 1 D O m Z 0 z tZ! m m v A Z