HomeMy WebLinkAboutWTR2703029.5N O 0 0 1 N 0 0 1 160 N) Y o z O ° o) S 3 O 0 a U a Z a� m N 22" STEEL CASING GROUT E W/CONC CENTER WATER LINE INSIDES PIPE SKID r%I lu CASING WITH TEFLON SKIDS OR AS RECOMMENDED BY AND STAINLESS STEEL SUPPORT MANUFACTURERS EQUAL SADDLE EQUAL TO CALPICO TO CALPICO AND CASCADE AND CASCADE PIPE SUPPORT. PIPE SUPPORT. SEAL ENDS SEAL ENDS WITH GROUT. WITH GROUT. Utility Section 1 Waterline Casing Detail 2 m ZZ <Q o YZ �C >N FOR 3/4" TO 2" DCVA, USE FOGTITE CONCRETE METER BOX NO. 2T (17"x28") WITH 3/8" STEEL COVER PLATE METER BOX SHALL BE DOUBLE STACKED. rzo FOR 2-1/2" TO 3" DCVA, USE UTILITY VAULT CO. MODEL 0 Z "_0 25TA OR EQUAL. Z°0 Z Q ° Q Z J Q _0 UNION (TYPICAL) FLUSH WITH FINISH GRADE (TYPICAL) 12"-16" 3: o- CLEARANCE 0 oz � ocn o w W � z w a 30" MIN. 30" MIN. cam- Q 6" CLEARANCE w o — _ .•_ r TO CITY METER = TO PRIVATE SYSTEM m E7/8" MINUS GRAVEL 12" MINIMUM z O_ C/) AFTER TESTING 8c APPROVAL, PLUG ALL TEST COCKS WITH BRASS PLUGS. +ndard Detail B 3/4n To 2" Double Check Valve Assembly 5 AFTER FIELD INSTALLATION, DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO CITY COUGHLIN PORTERLUNDEEN OF R E N TO N WATER UTILITY ENGINEERING A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION PRIOR TO ACTIVATION OF NEW LINE. � 217 PINE STREET -SUITE 300 P: 206/343-0460 �/ilTjp j� �Q19 SEATTLE, WA 98101 F: 206/343-5691 3" CLEARANCE (TYP) 12" MIN EMBEDMENT (TYP) TRENCH L------_._J 6' 0 ;E CONC AGAINST UNDISTURBED �H ON BEARING SIDE (TYP) NOTES: N 1. CURE CONIC MIN 7 DAYS PRIOR TO PRESSURE TESTING MAIN. REBAR @ 8" -CENTER BOTH WAYS 3/4" SHACKLE RODS (TYP) 12" MIN EMBEDMENT (TYP) 3" CLEARANCE (TYP) 12" PIPE THE NUMBER OF 8 - 3/4" SHACKLE RODS SHOWN ON THIS SHEET DEFINES ROD PLACEMENT CONCEPT ONLY. SEE ABOVE NOTE FOR NUMBER AND SIZE OF RODS REQUIRED. #4 REBAR @ 8" EACH WAY, EACH FACE Deadman Block 3 PLACE END SPACER MAXIMUM OF ONE (1) w AM 3 FOOT FROM END OF CASING (TYP.) MAXIMUM DISTANCE STEEL PIPE CASING (MILL PIPE) OR DUCTILE IRON BETWEEN SPACERS SHALL BE TEN (10) FEET O.C. I/ N 12" CASING SPACERS SHALL BE MAXIMUM OF ONE (1) FOOT FROM EACH SIDE OF PIPE JOINT (TYP.) SEAL END OF CASING WITH MANUFACTURED RUBBER END SEAL DEVICE CARRIER PIPE (DUCTILE IRON) CASING SPACERS (SEE APPROVED MATERIALS LIST) CARRIER PIPE DIAMETER 4" 6" 8" 10" 12" CASING DIAMETER (PUSH -ON JOINT CARRIER PIPE) 10" 12" 14" 16" 20" CASING DIAMETER (JOINT CARRIER PIPE) 14" 16" 18" 20" 22" STEEL CASING THICKNESS 0.25" 0.25" 0.25" 0.25" 0.25" SPACER BAND WIDTH 8" 8" 8" 8" 8" * 24" FOR DUCTILE IRON CASING. ANTICORROSIVE COATING THICKNESS:, CARRIER - 8 MILLS DFT T CASING - 8 MILLS DFT 6*�: NOTES: 1. CASING SPACERS SHALL BE "CENTER POSITIONING" TYPE.'.,... �3 2. MINIMUM RUNNER WIDTH SHALL BE 2 INCHES. 3. RUNNER HEIGHT SHALL BE SIZED TO PROVIDE: A. MINIMUM 0.75" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES. B. MINIMUM 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING DURING INSTALLATION. 4. STEEL CASING DIAMETERS ARE "OUTSIDE DIAMETER" FOR 16" AND LARGER. 5. SPACER BAND WIDTH SHALL BE 12" FOR CARRIER PIPES THAT ARE 36" DIAMETER OR GREATER Highlands Professional. Plaza: Elizabeth Odegard, Medina, Washing: I Casing Installation 6 ME �y x da �z c C7 C o N �r �> a w a N EXPIRES Oi/23/2,'�=