HomeMy WebLinkAboutWTR2703033.20 C o Q U O a O (0 c: . a � Y � E ,D _,Dw H W L- E w m a U s✓ V a CL 0 z < z r z Q z LJ j 2 S. Io z - lo I Y w U I U I cr� CL. I !¢ X w Z LJ U0 0 WATER UTILITY -GENERAL NOTES ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED BY THE CITY OF RENTON. A SET OF THE APPROVED PLANS SHALL BE KEPT ON SITE AT TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEK DAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE TRANSPORTATION DIVISION AT 277-6222. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE TRANSPORTATION DIVISION AT 277-6222 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOURS LOCATORS, 1800-424-5555. 4. ALL WATER MAIN PIPE TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINT TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105-77 STANDARDS. 5. CAST IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. CEMENT SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/A21.4-85. IF FITTINGS ARE 3 INCHES TO 12 INCHES IN DIAMETER AND HAVE A MECHANICAL JOINTS, THE FITTINGS SHALL BE IN ACCORDANCE WITH EITHER ANSI/AWWA C110/A21.10-82 OR ANSI/AWWA C153/A21.53-84. 3 INCHES TO 12 INCHES DIAMETER FITTINGS WHICH HAVE MECHANICAL JOINTS AND/ OR FLANGES JOINTS SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.82 OR A COMBINATION OF ANSI/AWWA C110/A21.10.82 AND ANSI/AWWA C153/A21.53-84 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE IN ACCORDANCE WITH ANSI/AWWA C153/A21.53-84 AND THAT PORTION OF THE FITTING WITH FLANGED JOINTS) SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION OF ANSI/AWWA C153/A21.53-84 OR WITH SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-82 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 6. GATE VALVES SHALL CONFORM TO AWWA C500 AND SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX. VALVES SHALL DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO A2380, OR M & H. ALL VALVES 12" IN DIAMETER AND LARGER SHALL BE INSTALLED IN AS VAULT. SEE WATER STANDARD DETAIL FOR 12" GATE VALVE ASSEMBLY VAULT AND 1" BYPASS INSTALLATION. 7. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) CONFORMING TO AWWA C-504-80 WITH A 6 INCH INLET AND A M.V.O. OF 5 INCHES, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD 7 INCH, 60 DEGREES V, THREADS, O.D. THREAD 4.875 AND ROOT DIAMETER 4.6263, 1-3/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE LEFT 8, ALL WATER MAIN 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36" BELOW FINISH GRADE. ALL WATER MAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATER MAINS ARE TO BE LOWERED TO CLEAR. 9. ALL WATER MAINS SIX (6 ) INCHES IN DIAMETER OR LARGER SHALL CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE OF THE "PIG" ONLY. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END, THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 10. ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. 11, ALL WATER MAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7- 11.3(12) F OF THE STANDARD SPECIFICATIONS REFERENCED IN 1 ABOVE. 12. A PRECONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF 10(TEN) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. PRIOR TO SCHEDULING THE PRECON, A PERMIT INFORMATION SHEET MUST BE SUPPLIED TO THE UTILITY ENGINEER'S OFFICE. TWENTY-FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 13. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION, 14. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. E NT 0 15, ALL CONNECTION TO EXISTING MAINS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE WATER UTILITY SECTION. ALL NECESSARY EXCAVATION AND MATERIALS TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS, 16. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE CITY INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR AS WELL AS THE ENGINEERS SHALL KEEP AS -BUILT DRAWINGS. 17. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 18. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO OR EQUAL APPROVED IN WRITING BY THE WATER UTILITY SECTION. 19. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES. OIL MAT STREETS MAYBE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURBS, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 20. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN TEN DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. TRENCHES WILL NOT BE LEFT OPEN OVER NIGHT WITHOUT PRIOR WRITTEN APPROVAL OF THE INSPECTOR. 21. FOR CITY PROJECTS SUCH TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 UNDER IMPROVED AREAS. ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. W TIE► - !% - .?61.0 FIRE HYDRANT SHALL BE COREY-TYPE EQUAL, TO IOWA F-51.10 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929 AND MUELLER SUPER CENTURION 200 WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS j NATIONAL STANDARD THREADS, 4" PUMPER CONNECTION CITY OF I SEATTLE THREADS WITH A STORTZ ADAPTOR, 4" SEATTLE THREAD X 5" STORTZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT No. 43 655 SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. -•- 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF SIDEWALK THATIS ADJACENT TO CURB TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. p EQUAL TO OLYMPIC FOUNDRY CO, STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION MAX 4" AS REQUIRED (SEE DWG BR46 / PAGE B090). MIN 2� / / - - RAISED PAVEMENT MARKER TYPE 88 AB STIMSONITE TWO-WAY BLUE. 42" ( MIN` CONCRETE BLOCKING BURY CONCRETE BLOCKING CAST IRON TEE. WITH 6' FLANGE SIDE OUTLET.. 12'� \� 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 111 DUCTILE IRON PIPE, CLASS 52 CEMENT LINED. LENGTH TO FIT TWO 3/4" STEEL TIE RODS. SEE STD DETAIL FOR TIE RODS, 16" x 8" x 4" MININU CONCRETE BLOCK UNDER HYDRANT 1/3 CU. YD. WASHED DRAIN ROCK (3" TO 3/8") FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY DETAIL DETAIL NO. BR24 NOT TO SCALE if 1 120 n EXIST.' 12" MAIN 16 GENERAL The amount of concrete required to anchor horizontal bends, tees, and dead ends depends on the strength of the soil. The methods of placing concrete to keep the joint accessible is shown in Figure 1. The area in square feet of concrete which must bear against the side of the trench is found by' dividing the thrust in pounds shown in Table l by the safe bearing load of the soil as shown in Table 2. CRITER'A 1. The sizing procedure is for horizontal or downward thrust only. 2. Height of the thrust block must be equal to or less than 1 /2 the depth from the ground surface to the block base. 3. The thrust block bearing face is approximately rectangular. 4. The concrete blocking shall be as per APWA Specification 74-2.14. SYMBOLS d = Outside Diameter of Pipe in Feet T = Thrust in Pounds at the Fitting (Table 1) SBL = Safe Bearing Load in Pounds/ q. Ft. (Table 2) h = Deoth of Trench in Feet W = Width of Trench in Feet A = Area of Concrete which must bear ago>nst the Side of the Trench in Sq. Ft. Hm = Maximum Height of the Thrust Block in feet Dc = Depth of the Concrete Thrust Block to Bearing Surface in Feet Lm = Maximum Length of the Thrust Block in Feet GROUND SUFACE BLOCK BASE CALCULATION EQUATIONS 1. Area of Concrete (A) = Thrust (In Pounds - T Safe Bearing Load (In Pounds/Sq. Ft,) - SBL 2, Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet - - h 2 - 2 Width of Trench in Feet) - 3. Depth of Concrete Thrust Block �Outside Diameter of Pipe in Feet) W-d = - = B 2 4. Maximum Length of Thrust Block (Lrn) = Area of Concrete - A Maximum Height Hm 5. Required Amount of Concrete (Cu. Yd.) _ (Height x Depth x Length) x 0.03704 (Hm x Lm x Dc) x 0.03704 E. EXAMPLE 1. Problem: Calculation of the amount of concrete required to block a 90' bend in an 8" C.I. water main; the normal operating pressure it the pipe will be 65 psi and the soil condition in the area indicates sand and gravel. 2. Solution: - Maximum testing pressure (See Table 1) = 300 psi. = 0.75 ft. - Outside diameter of 8" pipe = 9.05 in. = 9,05/12 - Go to Table 1: The testing pressure of 300 psi, we see - that the thrust_ a 90b s 91.360 pounds. - Go to Table 2: Table 2 gives the safe bearing load for sand angravel: 3,000 lbs./sq. ft. - Go to Figure 1: figure 1 indicates the position of the concrete for blocking the 90' bend. Go to the specifications of the project and find depth of trench h = 4 feet Width of trench W) = 3 feet With the above assembled information, we proceed to the final calculations: _ _ Area of Concrete (A) = Thrust 21,360 Safe Bearing Load 3,000 - 7.12 sq ft. - Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet 2 h 4 = 2.0 ft. T = 2 - Depth of Concrete Thrust Block (Dc) Width of Trench in Feet (W) - Outside Diameter of Pipe (d) = 2 = 3 - 0.75 = 1.13 ft. 2 - Maximum Length of Thrust Block (Lm) = Area of Concrete Height of Concrete A _ 7.12 = 3.56 ft. Hm 2.0 Required Amount of Concrete = (Height x Depth x Length) x 0.03704 = (Hm x Lm x Dc) x 0.03704 = (2.0 x 3.56 x 1.13) x 0.03704 = 0.30 cu. yd. TABLE 1 Size Pressure PSI -Thrust at Fittings in Pounds Tees , - 45 , 90 22-1/2 11-1/4 Dead Ends Bend Bend Bend Bend 3" 300 2,120 3,000 1,630 830 430 4" 300 3,780 5,370 2,910 1,470 750 6" 300 8,500 12,000 6,510 3:320 1,700 8" 300 15,100 21,360 11,550 5,880 3,020 10" 275 21,620 30.570 16,540 8,430 4,330 12" 250 33,930 48,060 25,950 13,260 6,780 14" 250 46,200 65,370 35,340 18,030 9,240 16" 225 45,250 64,000 34,620 17,650 ' 9,050 18" 200 50,900 72,000 38,940 19,860 101180 20" 200 88,900 48,080 24,520 12,560 24" 200 90,480 127,980 69,200 35,320 18,100 30" 200 �62,840 141,370 199,960 108,150 55,140 28,280 36" 200 203;580 287,950 155,740 79,400 40,720 TABLE 2 Safe Bearing Loads in Lb./Sq. Ft. The safe bearing loads given in the following table are for horizontal thrusts when the depth of cover over the pipe exceeds 2 feet. Safe Bearing Load SOIL Lb. per Sq. Ft. *Muck, peat, etc. 0 Soft Clay 1,000 Sand 2,000 Sand and Grovel 3,000 Sand and Gravel Cemented with Clay 4,000 Hard Shale 10,000 *In muck or peat, all thrusts shall be restrained by piles or tie rods to solid foundations or by removal of muck or peat and replacement with ballast of sufficient stability to resist thrusts. TA 36+69 (W-0304) _STA 10+58 ._..STA 14+14- NEW / f _- �' �� 1D x6 TEE- (1vfJxFL) - _ --� -- - --__ __ __---P-R-OPOSE-D FiNi I-F -GRADE ----- -- - -- - --- - - --- -- - GUT" IN EX. 12 D.I. 6,y�G.V. (FLxMJ) 13+41 1 - 12"x 10" TEE (FL) - - - - - - " -LF 6---D.I. -- - - - - - - _STA 10%6" TEE MJxFL T / 12 G.V.- (FI:xVJ) HYDRANT ASSY. 6" G.V. (FLxMJ),, 10p; G.V. (FLxMJ) CONC. BLOCKING 14 LF 6" D.I. o � -1-2 ADAPTOR (F MJ- - --- _HY/ __ 12" SPOOL.._- ICONC. INGRANT CO. BLOCK BLOCKI N.B. F__L 44 LF 10" D.I. � `j 283 LF 10" D.I. (� \:1 1rr, I r 9r) n 11 +00 Q '0 LEI 20 STA 34+59 (W-0304) - r - STA- 0+14--(NESN) WET TAP EX. 12" D.I. o' 10" G.V. CONC. _(TAPPINGxMJ)18 BLOCKING EXIST. 12" MAIN CAP 22-1 /20 45aBEND TEE FIGURE 1 NOTE: FOR CONVEX VERTICAL BENDS BLOCKING SEE APWA STANDARD PLAN NO. 73. CONCRETE BLOCKING SIZING PROCEDURE I ! Y O� ADOPTED CITY OF RENTON UL Standard plans LST DATE: 12 /15 /91 DWG. NAME: BR26 SP PAGE: BO85 12 MIN, HYDRANT ASSY. CONC.1 BLOCKING ` - �/ A.B. EL 20 16 143 LF 10 D.I, _ - - - - - - 4- CONTINED 200 LF, 10" D.I. 211 LF 10" D.I. ABOVE 1 LF_ 0 -_D1 __ --- 0+00 1+00j 2+00 3+00 4+00 5+00 6+00 SOUTH WATER MAIN PROFILE G v wA'JA sTA 1+s� -----' 'y 10 TEE (MJxFL) SCALE• HORIZ: 1*=30' o FM P�F ' �`` ' x6 vERT: 1"=2' 6" G.V. " ) DATE o a 0 , rev D.1. 20 LF 6" D.I, �S -' QU(�-� HYDRANT ASSY, 20734 �lv� CONC. BLOCKING PUII I���Rm►gTIC F3AsED oN F l ELD s� R� cy ay s NE MAR 2 8 W 10 NAL DR`l CO SURvEy 1 N4G . f o EXPIRES: 3 1 2004 GWNER &APPLICANT; jl/}I�z�1 KOHL EXCAVATING D 3 CITY OF RIF, NT'ON 3330 EAST VALLEY ROAD DEPARTMENT OF PUBLIC WORKS RENTON, WA, 98055 WATER DETAILS AND NOTES PHONE: (425) 251--8820 ENGINEER: JAEGER ENGINEERING KOHL EXCA VA PNG YARD PA VING As - eU t� � I zz�a 3 � -------------_____---- Southace DESIGNED: �� J� ATE: 5�2J/02 �- FILE NAME: Kent WA. 98031 DRANIN: JJ,i jLs - � -- - ---- -- - __------- -+, ------------- Phone No. (253) 850-0934 --- --- - I ; SCALL N o SCALE cHFCKED: FIELD BOOK: PAGE NO. t� ` PEVISION BY APPR. D - Fox No. (253) 850- 0155 APPROVED: OIREC TOR OF PIiBLIC WORKS SHEET C 5 OF: j L_% 1 r � w � � o CD o � NJ � o � y a O O W