Loading...
HomeMy WebLinkAboutWTR2703076.2fn z 0 N °Q z w 0 0 I 0 0 I o� O z m 0 ul ul w a a In uj W a a q z z 0 z W x x O z W ry o a N 0 o� VT� Y_c -0-E a � �w �E _ a) 0 w 0 U Z 3 Y w >W p ,n w 4a x a a In p 0 U Q n Q z 0 V) w ry O CITY OWNED ' AND MAINTAINED 1 L PRIVATELY OWNED AND MAINTAINED MAXIMUM PIPE LENGTH FROM PROPERTY LINE TO DDCVA MUST NOT EXCEED 50 FEET ®� 4 CONCRETE BOLLARDS • O Q z w � z I 0 J m z W Li :5 a- w 0 i cn W I Elf 0 I 5 FT. MAX. 13 12 1- MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY �40 SHALL NOT BE MORE THAN 50 FEET TO BUILDING) 2- BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER 3- CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS. 4- POST -INDICATOR VALVE (MJ) WITH TAMPER SWITCH 5- 2-90' BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6- 18" LONG SPOOL (FL x PE) 7- FLANGE COUPLING ADAPTOR 8- APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA 9- O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & I 10- METERED 3/4 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 3/4 INCH "SENSUS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED WITH A REMOTE READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL. 11- SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULT 12- 4"x 4" x 6" BULL, ELBOW, THREADED 13- UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. INSTALL BRASS PLUGS AT ALL TEST COCKS. 4 1 BUILDING WALL W J Y z T C9 z 0 m 1 w to VI w J Y z i2 a cn W LL. 0 PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON FLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK LETTERS TO SAY: "DO NOT BLOCK ACCESS" DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40' F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs. A RIGHT -OF -ENTRY AGREEMENT MUST BE GRANTED TO THE CITY OF RENTON FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO RENTON FIRE PREVENTION DEPARTMENT FOR REVIEW AND APPROVAL. A SEPARATE FIRE SPRINKLER PERMIST IS REQUIRED. 24 INCH MINIMUI 36 INCH MAXIMU FINISH FLOOR LEVEL ELEVATION VIEW OF DDCVA INSIDE BUILDING INSTALLATION FOR 3 INCH AND LARGER DETECTOR DOUBLE CHECK VALVE ASSEMBLY DWG. NAM E: . CITY OF RENTON STANDARD PLANS LST DATE:. SP PAGE:. FLOW DIFFUSER BAFFLE —6", SEE SITE PLAN CONTRACTOR SHALL ADJUST THIS DIMENSION BY INSTALLING SPACER BETWEEN VAULT & TOP 4" CLEANOUT �. 3' —0" NOTES: 1. CONNECTIONS TO CONCRETE WALLS WITH P.V.C. PIPE REQUIRE KOR-N-SEAL CONNECTOR OR A.C. X P.V.C. BRANT ADAPTOR SEAL ALL PIPE CONNECTIPONS WITH NONSHRINK GROUT. FLEX COUPLINGS SHALL BE EQUAL TO INDIANA SEAL #156-66 OR FERNO #1056-66. 2. OW-1 COVER, ACCESS DOOR & INSP. COVER SHALL BE HS-20 RATED + 30% IMPACT. ALL FASTENERS SHALL BE 316 STAINLESS STEEL. 3. CONTRACTOR SHALL FILL SYSTEM W/ WATER PRIOR TO SERVICE. 4. PROVIDE SAMPLING TEE AS SHOWN. 5. PROVIDE MIN. 2 SQ. FT. FREE OPENING @ INLET SECTION OF SAND/WATER INTERCEPTOR & MIN. 24" FROM OUTLET INVERT TO BOTTOM OF UNIT. 3" V TO ROOF TOP, ACCESS DOOR & INSPECTION COVERS. WATER LEVEL OW-1 FIN. GRADE _ FLOW DIRECTION 3" V TO ROOF, SEE PLAN VENT CONNECTIONS TO ATMOSPHERE " NON-SKID STL. COVER &3" FLEX. COUPLING o- — — � — �nP') I. E: 352.60' 448 ../NLETGALLON 6" OUTLETSI.E: 352.00' 716 . E: 352.50' 4 » 2"xi" STAINLESS REDUCER STEEL CLAMP W/ FLOW DIFFUSER �p. S.S. BOLTSBAFFLE OF 2 EA. END) W-1 OIL / WATER 18" MIN. SEPARATOR TRAP SEAL PRECAST CONCRETE VAULT, 6'-0"X4'-0"X3'-4\" UTILITY VAULT CO. INC. # 660-SA OR EQUAL. INSPECTION & ELEV: SAMPLING TEE 348.62' GRIT/SLUDGE WATER VOLUMN (VERIFY) RETAINER = 60 CU. FT. OR WEIR 448 GAL BAY DRAIN SCHEMATIC N.T.S. NOTES: SIZING CRITERIA FOR OIL 1. WASTE WATER SOURCE: 7 VEHICLE BAYS W/2 HOSE BIBBS ® 15 GPM EACH = 30 GPM (MAX.). 2. VEHICLES/HOUR WASHED : ASSUME 3 VEHICLES/HOUR. 3. SEPARATOR RETENTION TIME: 2 HOURS. 4. STORAGE FACTOR: 1.5. SIZING FORMULA: VEHIC./HR. X FLOW RATE X RETEN. TIME X STOR. FACTOR'=SIZE (MINIMUM LIQUID CAPACITY.) 3 X 30 X 2 X 1.5'=270 GAL. (MINIMUM LIQUID CAPACITY). Wlmb3W602 RECOMMENDED FOR APPROVAL BY: Date: BY: Date: / FLOOR ELEV: 356.50' 4" TO FLOOR DRAINS. I.E: 352.60' 6" MIN. WTR. SEAL BAFFLES SW1 SAND / WATER SEPARATOR CAPACITY: 365 GAL. W/ 49 CU. FT. HOLDING CAPACITY. 3/ 2 0 z wwP-s7-A7A BY: Date: BY: Cr_OIV iv. MDR 2 8 4003 Date: