EXISTING 8"
D.I. WATER
wrap-l7-jo96
wwio -1 -10,96
1
_ 10+00
SUNSET BLVD. N.E.
i
E w
3
X I ! 3
C.P §;M ' �- w o
V
C'0 ', W .
� K
12 LF 8"
CL 52
7 LF 8" D.I.
CL 52
f°
STA. 11 +53.48 (NE 6TH CT.) `
= STA. 10+00 (NEW BLAINE='CT. NE)
TO C11Y
LOCATION OF
EX. 6" SAN. SEWER @ 2.0%
REMOVE EXISTING WATER METER AND SERVICE
LINE TO MAIN. NEW METER SERVING EX. HOUSE
ON LOT 4 SHALL BE INSTALLED IN APPROPRIATE
LOCATION SHOWN. CONNECT NEW METER TO
EXISTING HOUSE USING J" COPPER PER CITY
DRAWING BR41. DURING ROAD CONSTRUCTION, A
TEMPORARY METER AND SERVICE LINE SHALL BE
PROVIDED OUTSIDE ROADWAY TO PROVIDE WATER
SERVICE TO EXISTING HOUSE.
r0Ei�a°LF LL.�h w2 /is3..ln E TEL. .�_". '!'.'!
Y... F _
ANCH'
8Yi-_,FORMER ' - -
G DROP APPROX. LOCATION OF
�1
EX. 6" SIDE SEWER _
ti TO LOT #4.
IE=157.76
P.
4AN
6
MIN. FF=165.0 6" STUB RODRAIN (TYP)
INSTALLJ" WATER METER
SERVICE LINE W/ PRESSURE (AS SH WN)
REDUCING VALVES IN ACCORDANCE
WITH CITY DETAIL BR45 (TYP.).
MIN. FF=174.0
O
l
-� £` � ► Mill
NOTE: `�---- ---- i
ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF ��
RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. MIN. FF=176.0 _190 ®_ ®' INSTALL 1" WATER METER
EXISTING 8" D.I. WATERLINE EXISTING 8" D.I. WATER LINE
I fT-
NEW 8" D.L.
"
WATER LINE NEW 8 D.I. WATER LINE
whim- 0
INSERT CLEANING "POLY -PIG" IN: ZAFTER ALL TESTING, CLEANING AND DISINFECTION,
8"x8" VERTICAL CROSS (MJxFL) REMOVE TEMP. BLOCK &BLOW -OFF &CONNECT
2-8" BLIND FLANGES (ONE W/ WITH 1-8"SLEEVE (MJ) & 8" D.I. SPOOLS AS REQUIRED
2" TAP & 2" PLUG)
1-8" PLUG (MJ) W/
2" TAP & 2" BLOW -OFF
TEMP. BLOCK
EXISTING 8" D.I.
WET TAP: (BY CITY FORCES) WATER LINE
8"x8" WET TAPPING TEE (MJxFL) W/ CONC. BLOCK
1-8" GATE VALVE (FLxMJ)
2-8" RO-MAC TRANSITION COUPLINGS
(8" D.I. TO 8" D.I.)
TEMP. BLOCK
TESTING DETAIL FINAL CONNECTION DETAIL
� CONNECTION AT N.E. 6TH CT.
By:
By:
By:
By:
AND SERVICE LINE, SEE
SPRINKLER NOTES, THIS
SHEET. INSTALL PRESSURE
REDUCING VALVES PER
CITY DETAIL BR45.
E=174.00
FUTURE MIN. FF=184.0
HOUSE TO
BE SPRINKLERED
RECOMMENDED FOR APPROVAL
Date:
Date:
WATERMAIN FITTING
DATA:
O
STA. 11 +33 (NE 6TH CT.), ON
®
STA. 11 +32.19, 4.10' RT.
FIELD LOCATE EX. 8" WATERMAIN
INSTALL:
1-4"114' BEND
AND INSTALL WET TAP WITH:
(MJ)
1-8"xB" WET TAPPING TEE (MJxFL)
CONCRETE THRUST BLOCKING
1-8" GATE VALVE (FLxMJ)
®STA.
11 +84.23, 5.41' RT.
CONCRETE THRUST BLOCKING
INSTALL:
20
STA. 10+05,62, 15.18' LT.
1-4"x114' BEND (MJ)
INSTALL
CONCRETE THRUST BLOCKING
1-8"x114° BEND (MJ)
©
INSTALL:
CONCRETE THRUST BLOCKING
STA. 12+21.56, 5.40' RT.
30
STA. 10+15.41, 9.06' LT.
(BLAINE STA. EXTENDED 5.0' RIGHT)
INSTALL:
1-4" D.I. CAP (MJ)
1-FIRE HYD. ASSY. (MJ)
1-2" PERMANENT BLOW -OFF ASSY.
1-8"x6" TEE (MJxFL)
2-4" PLUGS (MJ)
1-6" GATE VALVE (FLxMJ)
1-4"x4" VERTICAL CROSS (MJxMJ)
19 LF 6" D.I.
(FOR POLY -PIGGING)
1-8%4" REDUCER (FL)
CONCRETE THRUST BLOCKING
1-4" GATE VALVE (FLxMJ)
CONCRETE THRUST BLOCKING
FIRE SPRINKLER NOTES:
1. A RESIDENTIAL FIRE SPRINKLER SYSTEM IS REQUIRED FOR
LOTS 1, 2, 3 WITHIN THIS PLAT.
2. THE DEVELOPER MUST VERIFY THE MINIMUM SIZE OF THE
DOMESTIC WATER METER TO EACH LOT WITH A FIRE
SPRINKLER DESIGNER PRIOR TO THE INSTALLATION OF THE
WATER SERVICE STUB AND METER.
3. A SEPARATE FIRE SPRINKLER PLAN MUST BE SUBMITTED
TO RENTON FIRE DEPARTMENT FOR REVIEW AND PERMITTING
PRIOR TO INSTALLATION OF THE SPRINKLER SYSTEM. A
BACKFLOW PREVENTION DEVICE DOUBLE CHECK VALVE
ASSEMBLY IS REQUIRED FOR EACH BUILDING.
UTILITY X-ING
INFORMATION:
2�
T/P 8" SEWER=154.9
IE 4" WATER=156.2
3O
T/P 8" SS=156.5
IE 12" SD=159.43
®
T/P 4" WATER=157.33
IE 12" SD=159.5
5�
T/P 8" SS=167.86
IE 8" SD=169.3
©
T/P 6" SIDE SEWER=166.73
IE 4" WATER=174.0
7�
T/P 6" SIDE SEWER=168.81
IE 12" SD=170.0
®
T/P 6" SIDE SEWER=169.20
IE 4" WATER=176.0
DEVELOPER:
MICHAEL J. PRITTIE/ROBERT SMITH
P GIyu
pE W A Sy
8910 8TH AVENUE N.E.
SEATTLE, WA 98115
&I I syc
MIKE PRITTIE (206) 544-0212
ENGINEERZPLANNER/SURVEYOR:
�o ,P 23975 O ��
BARGHAUSEN CONSULTING ENGINEERS, INC.
`F Fc1STERF ��
18215 72ND AVENUE SOUTH
ss��NA L Epp\
KENT, WA 98032
(425)251-6222
EXPIRES 6-10-03
(425)251-8782 FAX
. G
- Awioq
d
00
N
O
N
cc
N
_o
N
I
N
0
I
CD
N
X
0
O
N
I I
0
U
CD
0
O
N
Ln
N
NCD
Q
0
cn
SURVEYOR'S NOTES:
PACIFIC NORTHWEST TITLE INSURANCE COMPANY ORDER No. 456722
DATED NOV. 5, 2001 WAS RELIED UPON FOR TITLE INFORMATION.
EASEMENTS Rec. No. 1737713, Rec. No. 5074957, Rec. No. 8803090649
ARE SHOWN. Rec. No. 9606210966 IS A CITY OF RENTON ORDINANCE
ESTABLISHING AN ASSESSMENT DISTRICT FOR SANITARY SEWER SERVICE.
HORIZONTAL DATUM - BASIS OF BEARINGS:
NAD 1983/91 (RENTON DATUM) C,
VERTICAL DATUM - BASIS OF ELEVATIONS:
In
NORTH AMERICAN VERTICAL DATUM OF 1988 NAVD 88 0
CITY OF RENTON BM #398 O
FND 4" x 4" CONIC MON IN CASE W/ PUNCHED 3/8" O
COPPER PLUG ON CENTERLINE OF EDMONDS AVE. NE
IN FRONT OF HOUSE NO. 801
ELEV. = 285.08 FEET
CALCULATED LAND AREA:
50,466 f sq. ft. [or 1.158 f Acre]
CITY OF RENTON
®EPARTMENT OF PUBLIG WORKS
WATER AND SEWER
EXTENSION PLAN
MAPLEfON SHORT PLAT
DESIGNED DATE 9/26/02 FILE NO.
DRAWN
CHECKED SCALE 1 "=20' FIELD BOOK PAGE
APPROVED DIRECTOR OF PUBLIC WORKS SHEET OF 8