HomeMy WebLinkAboutWTR2703100.2�-- (1 S ): O O o W Q Z O Z 3 V) I CL CL Z CL a 2 c J co 5 L Q z O Q cc Z WO Q W Z � � LC W Q Q m Q a) L0 Li U � a fU 0 w d d O L O 3 ~ w rn c c cc - 'IFm 0 z w z 3 S z U O O Z OU S O U (n Z o E 0 z � Q a 0 m C3 a o a W Z j W o 3 Q o o W U W � 0 > w Q EL FL CL IL EL s N N In r. M.".. E z O V) a�j ail aj U U, U aOf aOf a IW_W�_W E _ w Of of WATER UTILITY - GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED BY THE CITY OF RENTON. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT 235-2635. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE, CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. ALL WATER MAIN PIPE TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52 CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE INSTALLED SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105-77 STANDARDS. 5. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/A21.4-85. IF FITTINGS ARE 3 INCHES TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL BE IN ACCORDANCE WITH EITHER ANSI/AWWA C110/A21.10-82 OR ANSI/AWWA C153/A21.53-84. 3-INCH TO 12-INCH DIAMETER FITTINGS WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.82 OR A COMBINATION OF ANSI/AWWA C110/A21.10.82 AND ANSI/AWWA C153/A21.53-84 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S), MAY BE IN ACCORDANCE WITH ANSI/AWWA C153/A21.53-84 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53-5.3 OF ANSI/AWWA C153/A21.53-84 OR WITH SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-82 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 6. GATE VALVES SHALL CONFORM TO AWWA C500 AND SHALL BE IRON BODY, BRONZED -MOUNTED DOUBLE DISK WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX. VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380, OR M&H. ALL VALVES 12" IN DIAMETER AND LARGER, SHALL BE INSTALLED IN A VAULT. SEE WATER STANDARD DETAIL FOR 12" GATE VALVE ASSEMBLY VAULT AND 1" BYPASS INSTALLATION. 7. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) CONFORMING TO AWWA C-504-80 WITH A 6-INCH INLET AND A M.V.O. OF 5 INCHES, TWO 2/ 1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD 7-INCH, 60 DEGREES V. THREADS, O.D. THREAD 4.875 AND ROOT DIAMETER 4.6263, 1 1/4-INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 8. ALL WATER MAIN 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATER MAINS ARE TO BE LOWERED TO CLEAR. 9. ALL WATER MAINS SIX (6) INCHES IN DIAMETER AND LARGER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL .2 LB/CU FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 9A. ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. 98. ALL WATER MAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM SHALL CONCENTRATION) NOT BEPLACED THE CHLORINE/WATER AS A LA D SOLUTION. CALCIUM CHLORINE SHALL EMETERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED IN 1 ABOVE. 10. A PRECONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF 3 (THREE) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. PRIOR TO SCHEDULING THE PRECONSTRUCTION CONFERENCE, A PERMIT INFORMATION SHEET MUST BE SUPPLIED TO THE UTILITY ENGINEER'S OFFICE. TWENTY-FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 11. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 12. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 13. ALL CONNECTION TO EXISTING MAINS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. ALL NECESSARY EXCAVATION AND MATERIALS TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 14. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR AS WELL AS THE ENGINEERS SHALL KEEP AS -BUILT DRAWINGS. 15. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 16. ALL JOINT RESTRAINT SYSTEMS (SHACKLE, RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS, OHIO OR EQUAL APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. 17. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAW CUT TO A MINIMUM DEPTH OF TWO INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAW CUT TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 18. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN TEN DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. TRENCHES WILL NOT BE LEFT OPEN OVER NIGHT WITHOUT PRIOR WRITTEN APPROVAL OF THE INSPECTOR. 19. FOR CITY PROJECTS SUCH A TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 UNDER IMPROVED AREAS. ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULED 80 PVC PIPE. WPM.. - jk,* - h* 00 WATERMAIN EXTENSION NOTES AND DETAILS 12' x 22' CONCRETE METER BOX WITH w IN UNIMPR❑VED RIGHT OF WAY w 3/16" STEEL DIAM❑ND PLATE COVER EQUAL z INSTALL METER BOX AT TO FOG TITE METER SEAL CO. B-10 METER r PROPERTY LINE, > BOX. (DRILL 1-3/4' DIA. HOLE SEE DETAIL A -A) W W Li a 6' MIN C- SIDEWALK a FINISH GRADE 9' MAX ..a` = •• :: 21' MIN. �. ..` COVER T❑UCHREAD WATER METER 36" MIN. TO BE SUPPLIED BY THE CITY COVER TYPE "K' SOFT COPPER TUBING 12' MIN 3' MIN COVER 22' 1/2 ° / % L 0RD C❑PPERSETTER VH 72-15W-44-33G (FOP 5/8' x 3/4' METER) VH 74-15W44-44G (FOR 1' METER) NEW DUCTILE IR❑N ZLOOP DOWN TO CENTERLINE BOTH INLET AND OUTLET WITH PACK J❑INT WITH GRIPPER. WATERMAIN PADLOCK WINGS ON KEY VALVE SINGLE CHECK VALVE ❑F WATER MAIN T❑ PROVIDE ❑N OUTLET, SLACK IN METER, SERVICE ALL PACK-J❑INT FITTINGS SHALL BE WITH GRIPPER. LINE T❑ METER, C❑RP❑RATI❑N STOP. FORD TAPERED IF SERVICE LINE TO HOUSE IS T❑ BE THREAD (CC), PACK J❑INT (3/4" F1000) INSTALLED IN THE FUTURE INSTALL (1" F1000) FORD C14-33 OR 44 FIDT x C❑MPRESSI❑N C❑UPLING 22-1/2' 3/4' OR 1' GALVANIZED PLUG ji 1_ EX, CAST IR❑N ❑R FOR SERVICE FROM EXISTING STEEL DUCTILE IR❑N ASBESTOS CEMENT OR PVC WATER MAINS WATERMAIN INSTALL DOUBLE STRAP SERVICE CLAMP EQUAL TO MUELLER CO, 3/4" & 1 " WATER SERVICE NOTE TYPICAL RIB /� _ /� DRILL 1-3/4' DIA, HOLE FOR /'� A T❑UCHREAD DEVICE THE CENTER OF THE HOLE MUST ii \ Y O BE AT LEAST 1' FROM UNDERNEATH i 2-1/2' MIN. FROM NEAREST AND C T RIBS UNLESS THE RIB SPACING I FRONT EDGE ❑F PIT LID ALLOWS THE NUT TO TIGHTEN -_jI L-_--_- A AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. I I DATE REVISION I BY JAPPR'D DWG. NAME 2' CLOSE NIPPLE 2" 90° ELBEW CONCRETE BL❑CKING TWO PIECE CAST IR❑N VALVE EQUAL TO ❑LYMPIC FOUNDRY CO. STANDARD 8' TOP SECTI❑N, WITH REGULAR BASE SECTI❑N LENGTH TO FIT. 2' GATE VALVE, SCREWED 2' GALVANIZED PIPE 12' LONG 2' CLOSE NIPPLE ---- BETWEEN CAP OR PLUG AND 2' 900ELB❑W INSTALL 4 MIL POLYETHYLENE PLASTIC COVER OVER WASHED GRAVEL. CUT HOLE FOR PIPE 10 CU. FT. WASHED GRAVEL PASSING 1-1/2' AND RETAINED ON 1/4' MESH FOR DRAIN WATER MAIN 18' MAX. I .. • f l r-k/A-rTnni ADDITIONAL ADJUSTMENT IS REQUIRED, INSTALL 2-2' CLOSE NIPPLE AND 2-2" 900BEND, SCREWED AT THIS POINT. IF . FIELD LOCATE r CONCRETE METER BOX r 2" CLOSE NIPPLE 2' 900 ELBOW 2' GALVANIZED PIPE AS REQUIRED GROUND LINE /- CONCRETE SIDEWALK 2-1/2" NST (HOSE) BLOW -OFF HYDRANT EQUAL TO #78 KUPFERLE FOUNDRY CO. 2"x2'x2' TEE 2" CLOSE NIPPLE BEWTEEN TEE AND 90° ELBOW, 2' 900 ELBOW 2" GALVANIZED PIPE 18' L❑NF 2' CAP WITH 1/8' TAP FOR DRAIN PERMANENT 2' BLOW -OFF ASSEMBLY DATE I REVISION I BY APPR'D ADOPTED CITY OF RENTON Standard plans LST DATE: 6/02 BR41 SP PAGE:13106 PERMANENT 2" BLOW -OFF ASSEMBLY (FOR 8" MAINS AND SMALLER) 0� ADOPTED CITY OF RENTON Standard plans �01�' LST DATE:12/15/91 \Z DWG. NAME: BR25A SP PAGE: B105 DATE DATE DATE - _ _ _ EX. 10" DI CL 52 STA. 10+22.12, 14' LT. W*I' 'MI 09"N AND CONNECT: EX. 10" DI CL 52 1_ _ _ _ _ - _ 1-10"x8" TEE (MJxFL) 1-8" GATE VALVE (FLxMJ) 2-2 LF 8" DI PIPE 2-8" SLEEVES (MJ) rt 1-1-8" SLEEVE (MJ) CONCRETE BLOCKING NO-G'n ANEW 8" DI NEW 8" DI �INAV COHigy FpR(.� TESTING PROPOSED STA. 10+22.12, 14' LT. 1-8%8" CROSS FOR POLYPIG MJxFL) 2-8" BLIND FLANGES ONE Wt 2" TAP AND 2" PLUG 1-TEMPORARY 8" PLUG W/2" TAP AND 2" BLOW OFF ASS'Y TEMPORARY CONCRETE BLOCKING CONNECTION DETAIL AT S.E. 116TH ST NTS DEVELOPER: CHRISTINE BALYEAT 18724 S.E. 43RD STREET ISSAQUAH, WA 98027 (425) 643-1486 CONTACT: ENGINEER: HAL P. GRUBB, P.E. 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX NEW 10" DI COPORATION STOP FORD. FORD TAPERED THRREAD (CC). PACK JOINT (3/4" F1000) (1" F1000). (PER RENTON DWG. BR41) CONNECTION DETAIL N.T.S. w4mq3j0d)iO3 ' sIONA L EXPIRES 6-10-03 CITY OF RENTON DEPARTMENT OF PUBLIC WORKS SANITARY SEWER AND WATERMAIN EXTENSION DETAILS BALYEAT SHORT PLAT DESIGNED JGH DATE 3/14/02 FILE NO. DRAWN MFB -- -- CHECKED HPG SCALE AS SHOWN___ FIELD BOOK PAGE APPROVED 3LIC WORKS SHEET 5 OF 6 � r- X 0 2 0 E 0 N U cn 0 lfi 0 0 N N 0 E \ a� 0 0 CN 0 i 00 / c a� c a� / 00 n 0 0 0 0 / a - co O z m O W U m �a m k > ' co o � y m0 o � 0 � y �y 1 y