HomeMy WebLinkAboutWTR2703120.1REVISIONS: REVISIONS PER ARCHITECTURAL SITE PLAN
CHANGES. 05-27-03 DJW
REVISIONS PER CITY OF RENTON COMMENTS :REVISIONS PER CITY OF RENTON COMMENTS :REVISED WATER MAIN LAYOUT PER CITY OF RENTON
AND REDLINES, 06-03-03 DJW AND REDLINES. 07-02-03 DJW COMMENTS AND REDLINES, 07-15-03 DJW
0
o
0
Z
Y
O
Z
m
Q
W
o
a
o
V)
L.
r� O
LL Z
00 N
I.-
Z
U
WzW
U o�n CL
vv
aE
T \ E
rn
�I �N
c: g
vcu
0
U
� Z Z
= a-o
Z NZo
Z ��Q
p WO
rZJ
Q W Q
J
(n
Q
0
Z Z
W Y O
n 0 J aQ
Orf
a
a
Q
w
Q
0
z
0
V)
w
of
0
z
m
t c'
(n
ui
Q
0
rn
J,
T
co
STA.,,,2+66.68,
(SHATTUCK)
LEGEND
3 00
50LF 12" D.I.P.
12" WATER MAIN
30FL 6" D.I.P.
6" FIRE PROTECTION
V_+— 12" BEND WITH
CONC. BLIKG.
12"x4" REDUCER
12"x6" TEE AND 6" FIRE
t HYDRANT ASSEMBLY
6" FIRE DEPARTMENT CONNECT
�}a AIR/ VACUUM ASSEMBLY
—i METER
12" GATE VALVE
A PORTION OF SECTION 18, TOWNSHIP 23 N., RANAE 5 EAST., W.M.
NOTES:
1. ALL WORK PERFORMED AND MATERIALS USED SHALL BE IN
ACCORDANCE WITH CITY OF RENTON "STANDARD PLANS" DATED
JANUARY 21, 1997.
2. EXISITNG UNDERGROUND UTILITIES HAVE BEEN SHOWN FROM THE
MOST CURRENT INFORMATION AVAILABLE. IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO LOCATE ALL EXISITNG
UTILITIES, SHOWN OR NOT, PRIOR TO COMMENCING
CONSTRUCTION.
3. ALL WATER MAIN PIPE SHALL BE CEMENT LINED DUCTILE IRON,
CLASS 52 (AWWA C110 AND C111).
4. FIRE SPRINKLER SERVICE LINES SHOWN ARE FOR REFERENCE ONLY.
DESIGN BY OTHERS. SPRINKLER DESIGNER TO VERIFY PIPE SIZES
SHOWN. A SEPARATE PERMIT IS REQUIRED FOR THE INSTALLATION
OF THE FIRE SPRINKLER SYSTEM.
5. SEE SHEET C-10 FOR STANDARD CITY OF RENTON WATER NOTES.
6. ALL TRENCH RESTORATION IN THE PUBLIC RIGHT-OF-WAY SHALL
BE PER CITY OF RENTON TRENCH RESTORATION AND OVERLAY
DETAILS (HO32, H032A & H033).
7. ALL NEW ELECTRICAL, PHONE AND CABLE SERVICES AND LINES TO
THE PROJECT MUST BE UNDERGROUND. LOCATIONS FOR THESE
FRANCHISE UTILITIES WILL BE DESIGNED BY THEIR RESPECTIVE
PURVEYORS. IN GENERAL,, REQUIRIED UNDERGROUND CONDUIT
AND PIPE, METERS, TRANSFORMERS, 'UNCTION BOXES, ETC. WILL
BE LOCATED IN LANDSCAPE AREAS, UNDER SIDEWALKS OR IN
PAVEMENT CORRIDORS WHICH WILL NOT CONFLICT WITH
PROPOSED WATER, SANITARY SEWER OR STORM DRAINAGE
UTILITIES. CONSTRUCTION OF THESE FRANCHISE UTILITIES MUST
BE INSPECTED AND APPROVED BY A CITY OF RENTON PUBLIC
WORKS INSPECTOR PRIOR TO A CERTIFICATE OF OCCUPANCY BEING
ISSUED.
CONNECT TO EXISTING 4" WATER
MAIN WITH:
1- 12"x 4" REDUCER (FLxMJ)
(SEE SHEET C15, FOR .
CONNECTION DETAILS.)
1- 1" AIR/ VAC ASSEMBLY
A%lbuilt l►rawtnes:
Ash iiIT inUlrmmitni siKvM nefM45fCIQl field MNVeY
by c entre`Pointe swvevul& ilr-*f*e
samt iry sewer am war
Inavvc%SI1* '
tTum the amsm h
33701 9th AveaWS666
- STA. 3+32.98, 27' LT. f euerai Wev. WA 98 `l.�
1- 12"x6" TEE (FL) WITH 'S3-66t-1J1
CONCRETE BLOCKING 253-661-7719 Fax
1- 6" GATE VALVE (FLxMJ)
1- 6" FIRE HYDRANT ASSMY.
nATI IAA
CITY OF RENTON (NAVD 88)
BENCHMARK
BASE:
CITY OF RENTON BENCHMARK NO. 2123: FOUND USGS BRASS
DISC STAMPED "Q462", VERTICAL IN WALL OF POST OFFICE.
1.5' E OF SOUTHWEST CORNER OF BUILDING LOCATED IN THE
NORTHEAST QUADRANT OF STREET INTERSECTION OF HOUSER
WAY AND WILLIAMS. AS PER PHONE CONVERSATION WITH BOB
MACONIE ON JANUARY 11, 2001.
ELEVATION = 45.11 FEET.
SITE:
FOUND BRASS PLUG IN CONCRETE INCASED AT INTERSECTION
OF 4TH AND SHATTUCK STREETS.
20 10 0 20
NOTE:
SEE SHEET C10b FOR IRRIGATION METER LOCATION.
CONTRACTOR TO ENSURE THAT STORZ FITTINGS ARE
INSTALLED ON EXISTING FIRE HYDRANTS IN THE VICINITY
OF THIS EVELOPMENT. (SEE SHEET CO2 FOR LOCATIONS.)
H5—QUILT INfORMTI0N PROVIDED BY:.
CENTRI✓ POINTE. SURVEYIWINC., P.S.
33701 - 9th AVENUE S.
OQ
L L""o�. FEDERRL WAY, WA 96003
". PHONE' 253— (o(o I -1901
CHECKED FOR COMPLIANCE RECOMMENDED
TO CITY STANDARDS FOR APPROVAL
1
r k a ud Date Suer ��, 2�c3 BY:
'�✓ `�,f� Date 1103 BY:
Date ' BY:
-�'�i(ot2r t5�03
rEXPIRES:
L
U7
00
Ijj
Q
0
Q
o0
0
0000
0
�
oo
ao
U
zz
n
Lu
5 P
0
SOWN
N�jZ
0
I.- Z
Z 0
.. , ...
Ln X
LO m
W
0
aoIIN"QLL
cc 0-u
c"W>Q
cd
WQ
^�
Q
Z
0
W
.J
Q
W
LL
U co
OW
D WO 11
0_0 00
� M
U =�
Qz o
0
UX0()
Z 0zLL
0 Q
i Q U W O
WO
12-
OO1cmcoo)
Zr^ 00-U)<
QW -ILz�:o
Q m<0OwN
OWQ_W
f. U
frLL'VJ (L IL UOrncna
PROJECT NO.: 00-25
DRAWN BY: DJW
ISSUE DATE: 04-03-03
SHEET REV.: 07-15-03
WATER PLAN AND
PROFILE
c 1
SHEET OF
C
z
x
°z
41�
N
O = >
�a
o vd
d
°z
b
x
a
�
Y
N
W r f - 2, —.?/."
A OCT 0 8 ra
S;—IANNFD NOV o 7 2003