HomeMy WebLinkAboutWTR2703127.3� c { io N I� m o o m w o �_aw a 0 V) I CL a- O w V) � � Q L~L..I oO 48 o e- � Z cn _ af LLI O m Q Z o w J wUZ z }/• Z N Z O O Q 1 0 0 0 0 Y Z Z Y w O n a T a v�i o o a ry a_ n a w Z 0 > Ld 0 Z WATER UTILITY NOTES 8c SPECIFICATIONS LITHIAHYUNDAI - RENTON 1. THESE NOTES SHALL APPEAR FOR PROJECTS FOR THE WATER UTILITY. PORTION OF NE 1/4, NE 1/4 OF SECTION 19, TWP. 23 N., RGE. 5 E., W.M. 2. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF CITY OF RENTON, KING COUNTY, WASHINGTON RENTON PLANNING/BUILDING/ PUBLIC WORKS DEPARTMENT AND THE 1996 EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. DURING CONSTRUCTION, 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 3. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY CONSTRUCTION. WORK IN THE RIGHT OF WAY. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL 4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR TO THE CITY OF RENTON. UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, 5. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 ON -SITE PRIOR TO CITY NOTIFICATIONS. OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEA) COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA CIOS/A21.5-93 CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF STANDARDS. BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA CIIO/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ANSI/AWWA C104/421/4-90, IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, ACCEPTANCE PRIOR TO FINAL TIE-IN. THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE C1531/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF DEPARTMENT, ANSI/AWWA CIIO/A21.10.87 AND ANSI/AWWA C153/A21,53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND TW. PORTION OF THE FITTING WITH 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA CIIO/A21,10-87 SHALL BE DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. EXISTING EXPANSION JOINT. 8. GATE VALES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509), VALVES SHALL BE DESIGNED PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI, GATE VALVES SHALL BE CLOW LIST 14, MUELLER INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH.* COMPANY NO. A2380 OR M & H. 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN UNDER IMPROVED AREAS. VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V, THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4,6263, HYDRANTS SHALL HAVE: ° 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT), 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAWS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ, STORZ ADAPTER SHALL BE FORGED AND/OR -.XTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART, STORZ FACE TO BE METAL, NO GASKET TO WEATHER, STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1 /8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL Pc PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE, WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A CLUROMETER URETHANE RUBBER COATING AN THE REAR OF "'PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END, THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION, 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT, ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTITIVP* OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER Or GML.LONS PER HOUR AS LISTED IN CI, OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METER ED/INJECTElI IN ACCORDANCE WITH SECTION 711.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. !i -3/l7 CITY OWNED I PRIVATELY OWNED AND MAINTAINED AND MAINTAINED I MAXIMUM PIPE LENGTH FROM PROPERTY LINE TO DDCVA MUST NOT EXCEED 50 FEET I I O CONCRETE BOLLARDS O O I• • O n -y- 5 . MAX. Q -�- EXISTING CURB LINE la � A w z �I�J �Iz �IW W x CL W 0 I w C W 1- MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY o SHALL NOT BE MORE THAN 50 FEET TO BUILDING) 2- BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER 3- CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) 13 12 ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS. 4- POST -INDICATOR VALVE (MJ) WITH TAMPER SWITCH 5- 2-90' BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6- 18" LONG SPOOL (FL x PE) 7- FLANGE COUPLING ADAPTOR 8- APPROVED DDCVA ON .MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED UST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA 9- O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & I 10- METERED 3/4 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 3/4 INCH "INVENSYS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED WITH A REMOTE READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL 11- SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULT 12- 4"x 4" x 6" BULL, ELBOW, THREADED 13- UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTtR. TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. INSTALL BRASS PLUGS AT ALL TEST COCKS. CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 FIRE SPRINKLER NOTE WHERE THE UNDERGROUND WATER SUPPLY TEES OFF TO SERVE ONLY A FIRE SPRINKLER SYSTEM, A SEPARATE DETAILED PLAN MUST BE SUBMITTED AND APPROVED BY THE FIRE MARSHAL PRIOR TO INSTALLATION. FIRE PROTECTION NOTES THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM, INCLUDING HYDRANT LOCATIONS, MAY DEVIATE FROM THE SYSTEM SHOWN. THE FINAL DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHALL. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 'i1E8E DRAMIMOS ARE ISSUED FOR AGENCY PEROT REYEMI PURPOSES ONLY AID ARE NOT TO BE USED FOR CONSTRUCTION'. W3127 BUILDING WALL O O W VN INC N 48 INCH J Y WALL z a N W Lc c� - z --- - 0 Im i 101 RECOMMENDED FOR APPROVAL RY BY BY N N W U 0 !a Y U 0 m 10 z 0 0 PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON rLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK LETTERS "DO NOT BLOCK ACCESS" TO SAY: DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs. A RIGHT -OF -ENTRY AGREEMENT MUST BE GRANTED TO THE CITY OF RENTON FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO RENTON FIRE PREVENTION DEPARTMENT FOR REVIEW AND APPROVAL A SEPARATE FIRE SPRINKLER PERMIST IS REQUIR D. �14 S . Gq of wash%� P � G : ff 24 INCH MU '� 36 INCH MA z cic CL �tn W ELEVATION VIEW OF DDCVA 0 CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE o !o-03 DATE 1U DATE 2 REVISIONS PER CffY COMMENTS DMB 10/1 / 1 REVISIONS PER CITY COMMENTS DMB 9/12/ NO. REVISION BY APPR. DATE 23467 0���ECST IE ONALgSt xPIR REUSE OF DOCUMENTS THIS DOCUMENT HAS BEEN SIGNED ELECTRONICALLY IN ACCORDANCE WITH WAC 196-23-070 AND CHAPTER 19.34 RCW. UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT MALL INVALIDATE THE DOCUMENT, MY CERTIFICATION AND SIGNATURE. THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF AHBL AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF AN& W z Qo � Z 0 = 4Q 0 U) Z O 0 0 Z N w CITY OF RENTON DEPARTMENT OF PUBLIC WORKS UTILITY NOTES & DETAILS DESIGNED: DB DRAWN: MCC CHECKED: DSG APPROVED: DATE: 06-20-2003 SCALE: NTS mm=T= Or ►Lauc WON= Oz C3.3 m O FILE NAME: 203046c33 FIELD BOOK+- PAGE: - SHEET: 10 OF: 10