GRAPHIC SCALE
2C 0 10 ) 40
IN FEET )
I inch - 20 ft.
wrk, s?4#
PLAN
SCALE: 1 " 20'
PROFILE - ALONG PIPE
SCAL E. 1" 20' (H) 1" — 5' (V )
CHECKED FOR COMPLIANCE
T CITY STANDARDS
Date L7'O
Date
PAD OAL/ (;4* k Date 300104
BY
BY
Uo
FINISHED GRADE
TYPE 230 FRAME &
COVER MARKED
'WATER`
X
Z oo //o N ✓ s///
MIN 3 COURSES CONC
o / / / / / / / / / / BLOCK & MORTAR
TEST BOX
TEST STATION WIRES
(NUMBER VARIES)
PROVIDE 3'-v'+M OF
SLACK BETWEEN TEST
BOX AND CONDUIT
11 j4"G SCHEDULE 40 iPACTED SUBGRADE
ELECTRICAL GRADE PVC CONDUIT (95%)
TO PIPE AND REFERENCE CELL ELEVATION
SEE STD PLAN NO 363 MINERAL AGGREGATE
ELECTROLYSIS TEST STATION — TRAFFIC AREA TYPE 9 6-MIN DEPTH
STANDARD OLYMPIC FOUNDRY TEST STATION WIRES (NUMBER
TYPE SM29 BOX & LID VARIES) PROVIDE 2'-O"MIN OF
CONCRETE COLLAR 6" SLACK BETWEEN TEST BOX &
P �N ALL � —� 2"CLR(TYP) CONDUIT
\ \1 \ 1 FINISHED GRADE
T
iX� �� 00101 _
MINERAL AGGREGA
TYPE 9
NUMBER OF TERMINALS
EQUALS NUMBER OF TEST
WIRES PLUS 1
1 /4"MOUNTING
HOLES LOCATIONS
DETERMINED BY
TEST BOX SIZE &
MANUFACTURER (TYP}�
1 /4'-20 NICKEL- \
PLATED BRASS NUTS
NICKEL -PLATED
BRASS CUT WASHER----
NICKEL-PLATED BRASS
LOCKWASHER
1 /4°-20 NICKEL -
PLATED BRASS BOLT/
CRIMP TYPE
SPACE
6.75"X4.88"X1 /4"
PHENOLIC PANEL
NEST WIRE (TYP)
WIRE
IDENTIFICATION
WHEN SPECIFIED
IN CONTRACT
DOCUMENTS
Ln
(TEST STATION WIRES &
TERMINALS NOT SHOWN)
TEST BOX A
TERMINAL BOARD
ELECTROLYSIS TEST STATION — NON —TRAFFIC AREA
WATERMAIN ELECTROLYSIS TEST STATION
O-RING
CABLE ENTRY
NOTE:
WIRE INSTALLATION PER
STD SPEC SEC 9-30.12(3)
THERMITE WELD CONNECTION
SEE STD PLAN NO 362-
#6 AWG, BLACK TEST STATION WIRE
#10 AWG. BLACK TEST STATION MARE
#10 AWG, YELLOW
11/40 CONDUIT TO TEST STATION
SEE STD PLAN
NO 360
TERMINATE END
T AS
Y I ei4 LCLOSE TOOF IMAIN
ZINC REFERENCE CELL'' 4-EX WATERMAIN
PLACE AT SPRING LINE OR BELOW,
4'f2' FROM WATER MAIN
STANDARD 3—WIRE TEST
STATION
III AWG, BLACK
#10 AWG, BLACK
THERMITE WELD CONNECTION
SEE STD PLAN
NO 362 —�
/10 AWG. YELLOW
#10 AWG. WHITE
#6 AWG. WHITE
1i/40 SCH 40 ELECTRICAL GRADE
PVC CONDUIT TO TEST STATION
SEE STD PLAN
NO 360 —�
EXISTING
ZINC REFERENCE CELL-/
`MI IJLA I INIi L-EX WATERMAIN
TERMINAL
PLACE AT SPRING LINE OR BELOW,
RUBBER BOOT
BOARD
4'f2" FROM WATER MAIN
INSULATING COUPLING
NEMA TYPE 4X
INSULATING COUPLING
5—WIRE TEST STATION
ENCLOSURE
WHINGED COVER.
HOFFMAN BRAND
i 410 AWG, YELLOW
OR APPROVED
#10 AWG, WHITE
EQUAL
0 AWG, WHITE
06 AWG, BLACK
f0 AWG, BLACK
1t/40 SCH 40 ELECTRICAL GRADE
PVC CONDUIT TO TEST STATION
THERMITE WELD CONNECTION
SEE STD PLAN
SEE STD PLAN
NO 360
NO 362
TYPE E NEOPRENE
FACED PHENOLIC NEW EXISTING
INSULATING GASKET
PHENOLIC OR SPIRAL
WOUND MYLAR
INSULATING SLEEVE ZINC REFERENCE CELLEX WATERMAIN
(LENGTH OF SLEEVE PLACE AT SPRING LINE OR BELOW, INSULATING FLANGE JM
TO BE 1/16• LESS 4't2' FROM WATER MAIN SEE SECTION DETAIL
THAN SPACING INSULATING FLANGE 5—WIRE TEST STATION
BETWEEN STEEL
WASHERS)
PHENOLIC INSULATING
WASHER
• y - IIj�(I
INSULATING
FLANGE SECTION
DETAIL
ELECTROLYSIS
TEST
STATION — WIRE INSTALLATION DETAILS
CATHODIC PROTECTION DETAILS FOR CEDAR RIVER PIPELINE CROSSING — SEE SHEET 3
N.T.S.
MIN. 3'
COVER
BLOWN SAND (OR CDF FILL OPTIONAL)
15" SANITARY SEWER CARRIER PIPE-
- 24"x1 /4"x236.6' STEEL CASING PIPE
CASEMENT FOR DEEP PIPE
N.T.S.
sk
-07
bL 40 ir 4&
MiDERGROb PIPE LOCATION BASED ON SMA k-kAnMM AVll;AL
LOCATION MAY VAFtiP
I CONFIRM FIAT THE LOCATIONS, ELEVATIONS, DEMUS, AND AS-WrLT
CON041EWS RE,r , TNIG MATERIALS AI;'TUA LLY USED DURINO
CONS'FRUC LION, ACCURATELY REFUCTS EXISTING FIELD CONDfI I€DNS AS
DETERMINED NE CIR LI DER MY DIRECT SITPERVISION ON TEAS
DATE:
6
1515
NA L
EXPIRES 9 JAN
F 2006
ST.MP NOT VALID UNLESS SIGNED & DATED
w /
DALEY-MORROW-POBLETE, INC.
726 AUBURN WAY N.
AUBURN, WASHINGTON 98002
PHONE: 253-333-2200, FAX: 2533332206
in corporoteci
ENGINEERING — SURVEYINV _A
LAND PLANNING
SCANNED OCT 0 8 Z-oOP-