Loading...
HomeMy WebLinkAboutWTR2703140.1� _ (n w 0 Q CL O J (n �Q Q z IJ O U <L zry Li ry rn U� all O F— i Z ' O z 6 ;r N W _o V / O O Q Lo ZW Q o J U � � 3 0 o(n Y W > W C w 6 W U Z Y O V O n U Q a' Q T,;��, Q cl LU C) J O0 O U? C) w Q ch� HARMS°EN & ASSOCIATES INC. ENGINEERS SURVEYORS PLANNERS 17614 - 162ND ST. SE POST OFFICE BOX 516 MONROE, WA 98272-0516 360-794-781 1 206-343-5903 360-794-9087 (FAX) a z IS9T�r'" ti OVAL `� a EXPIRES: 10/27/05 FINISHED GRADE ELEVATION TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE INSTALL 2" PLUG ON TOP BLIND FLANGE 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) AFTER REMOVAL OF POLYPIG 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) \ NEW WATER MAIN POLYPIG VERTICAL CROSS FOR POLYPIGGING STATION: SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG") ONE BLIND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN O W RECOMMENDED w FOR APPROVAL O O Q BY d JBY BY WATER PAIN POLYPIGGING STATION VERTICAL CROSS FOR POLYPIGGING �, Y p4\1 ADOPTED OTlf or valu It + 9TMARD PLiNB O LOT DAM 06/2W3 DWG. NAME: BRX5 SP PAGE: Bl l4 CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE �✓ DATE O DATE 30, w Z w Q 3 0 TESTING DETAIL Z N x 4- Q CT W TAPPING TEE (MJxFL) TAPPING GATE VALVE (FL XMJ) TEMPORARY PLUG (MJ) WITH 2-INCH TAP AND 2-INCH BLOW -OFF ASSEMBLY CONCRETE BLOCKING NEW D.I. WATER LINE VERTICAL CROSS(MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) WITH 2"TAP & 2" BLOW -OFF TEMPORARY BLOCK NOTES: 1. TAPPING TEES SHALL BE MADE OF DUCTILE IRON OR EPDXY - COATED STEEL. 2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. 3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4. WET -TAP SHALL BE DONE ONLY BY CITY -APPROVED CONTRACTORS 5. CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF EXISTING LINE OR STUB AND SHALL START LAYING THE NEW LINE AT THE SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE EXISTING STUB, CITY FORCES WILL PERFORM THE FINAL CONNECTION FROM THE WATER LINE TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL CITY OWNED ! AND MAINTAINED PRIVATELY OWNED AND MAINTAINED No — MAXIMUM PIPE LENGTH FROM PROPERTY LINE TO DDCVA MUST NOT EXCEED 50 FEET BUILDING WALL 2 3 4 4 CONCRETE BOLLARDS zl 10 N nn O 000 ® ® O- � 5 FT. MAX. 6 O a z ~ W � `� Z O r ~ V W L ory- O cn d J J a 3 z 0 J D 13 12 11 00 1- MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY SHALL NOT BE MORE THAN 50 FEET TO BUILDING) 2- BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER 3- CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS. 4- POST -INDICATOR VALVE (MJ) WITH TAMPER SWITCH 5- 2-90' BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6- 18" LONG SPOOL (FL x PE) 7- FLANGE COUPLING ADAPTOR 8- APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA 9- O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANcE WITH L & I 10- METERED 3/4 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 3/4 INCH "INVENSYS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED WITH A REMOTE READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL. 1 1- SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULT 12- 4"x 4" x 6" BULL, ELBOW, THREADED 13- UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SL18MITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. INSTALL BRASS PLUGS AT ALL TEST COCKS. 9 V, C:�0 1® a Y O � c o z 4 INCH Li ~ >G C c 48 INCH W J Y Z. EL V) w Z 0 J 0 07 0 w V) r V) w w J Y Z a a V) W U. 0 F- FINAL CONNECTION DETAIL NEW D.I. WATER LINE AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTION BY CITY FORCES WATER CONNECTION DETAIL WET -TAP EXISTING WATER MAIN ADOPTED CITY OF RENTON ♦ I♦ STANDARD PLANS IM DATE: 06 2003 PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON FLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK LETTERS TO SAY: "DO NOT BLOCK ACCESS" DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40' F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs. A RIGHT -OF -ENTRY AGREEMENT MUST BE GRANTED TO THE CITY OF RENTON FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO RENTON FIRE PREVENTION DEPARTMENT FOR REVIEW AND APPROVAL. A SEPARATE FIRE SPRINKLER PERMIST IS REQUIRED. 24 INCH MINIMUI 36 INCH MAXIMU 6 2003 REVISE METER FROM SENSUS TO INVENSYS AG DATE REVISION BY APPR FINISH FLOOR LEVEL ELEVATION VIEW OF DDCVA 1. DWG. NAM E: CITY OF RENTON STANDARD PLANS LST DATE:.