Loading...
HomeMy WebLinkAboutSWP2703146.3- _ - RIM EL-:5 EX CB 96.9 EX CB RIM EL=396.9 EX 12"PVC - S 12"IE=393.65 � N 12"IE=395.75 IE-394 N 12"IE=393.56 12"DI EX. ROCK- WALL ° a WOOD RAIL FENCE WETLAND TRACT 4" PVC Drain 4-a NO MACHINERY ALLOWED From Rockery - LO ALL MACHINERY SHALL WORK` a W SSMH FROM TOP OF BANK 24" IE-392.5 ° � RIM E�-.59 %.65 z � IN IE389.12 -----.Q U T I E 3 8 9.0 2 INSTALL NEW CB TYPE II r`r REBUILD SLOPE, SEE DETAIL---- rr r, _ r rt' Removed Reinstalled '`tl` r" a �- Sign, Fence. r`r� - HOA Relocd Plants STOP I FENCE APPX TOP - 'h`r", OF SLOPE ° TEL BO CATU - 4 FX 8"PVC SS ;< �„PVC S N CALL 48 HOURS BEFORE YOU DIG -- - - - 1-800-424-5555 0, 10' EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. SCALE: 1 "= 10' NOTE: EX FIBER OPTICS APPROX. 2' DEEP ENCASED IN CONCRETE uC - a -, - -_ - � EX 1 2"CI WM RESTORE CURB, GUTTER, SIDEWALK, 3 PARKING LANE INSTALL NEW SIDE ALK RAMP TYPE 2 �D 8"W, ADJUST T FIT EX SIDEWALK U - - - - - ___E7 6" 7A_S Relocated 1 2" WM TRAFFIC LAf. UNION AVE N E REMOVE EX 24 CMP SID See Sheet 4 INSTALL NEW 24" SID EX 24"CMP SD -� EX 24"CMP SD _ TRAFFIC LANE -0- EX SDMH t RIM EL=399.1 - , RKING LANE CAUTION: POSSIBLE BURIED CABLE AND FIBER OPTICS IN WEST HALF OF STREET RCW PROFILE ALONG NEW PIPE LINE SCALE HORIZ: 1 "= 10' .............. ......... ............................. _ - - - _ - - - - VERT: 1 _ _............................................................ "= 5' ....._... ..- - - - REMOVE WOOD FENCE AND NEIGHBORHOOD :SIGN NEIGHBORHOOD SIGN STORE, RESTORE AFTER CONSTRUCTION / Location Ap:px / EX SDMH :... :.......... :PWR, TELE, CABLE ?... RIM. EL 3.9:9,.1........... :............. :..... - REBUILD SLOPE 2H:1V (MIN) .. LOC UNK N 24"CMP I.E 391.6 ................... ............. ............ ADJUST TO FIT LOCATION,. SEE DETAIL : FIBER OPTIC f 4' DEEP " NEW E 24" IE=391.6 CONC. Cover, S 24"CMP IE 391.6 Conduits Below Conc. 6" GAS 400 ...C.B.. TYPE .11 .48''. AND OVERFLOW.. GRATE ... 12"W .:.......DEPTH..APPX ................ _ _ :..... _ ......400 SEE DETAIL, REVIEW LOCATION WITH :_ -- - _ DEPTH APPX - - CITY POTHOLE RESULTS - 8/7/09 CITY BEFORE PLACING CB -- - - ABND 8"W - SDMH 24" IE 391.59 Ril ° Cut, Capped CULVERT 24" INLET IE 1392.E 0. 000 GAS 6" TOP EL :395.1 3.9� _ DEBRIC BARRIER-11 SEE .DETAIL.....:... _... _ .... WATER 12" DIP EL 'OPTIC .BANK : 394.52 -. - -- - __ -r- 0 FIBER CONIC TOP 397.8E- n BOTTOM 396.45 I:I MATCH EX CULVERT IE�-39 6 012"W 10" into SD,....:.... O Aga .............. - - ..... .. was new . .. _ ............ _ 390 - 392.5 O 1 .. O : Relocated above new SD w/45. Bends N 9 8 5S NEW CB RIM EL=395.80 Est IE=389.25 REMOVE EX 24"CMP, INSTALL IN IE=392.35 60 LF 24"CPEP @ 0.017 FT/FT OUT IE=392.30 - �AA A = ADJUST LENGTH AS NEEDED RECOMMENDED FOR APPROVAL BY DANIEL CAREY 6/29/10 BY o z ,\ xxxxx �. O� ' b/STokF,\�F.. ORIGINAL PLAN STAMPED AND SIGNED 6/30/10 BY: RONALD J. STRAKA PE# 29727 EXPIRES 10/16/11 1 ADDED AS -BUILT INFO, ADDED 12'W RELOCATION DWC 12/8/10 DWC SURVEYED: REMOVED OLD INFO, OLD CONSTR. NOTES, CLEANED UP DRAVANG. DESIGNED: DWC DRAWN: DWC CHECKED: RJS, DWC N0. REVISION BY DATE APPR APPROVED: RJS SCALE: As Noted ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM GENERAL NOTES: A. THIS PLAN DEVELOPED FROM PLANS AND ELEVATIONS IN CITY FILES. NOT SURVEYED. LOCATIONS MAY VARY. REF: TED-40-2956 THE VINEYARDS SUBDIVISION TED-40-1600 UNION AVE PLANS B. CONTRACTOR SHALL INSTALL EROSION CONTROL, INCLUDING FILTER FABRIC PROTECTION FOR DOWNSTREAM CATCHBASINS. C. TRENCH PATCH SHALL BE PER CITY STD PLAN 110 TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT. D. SEE TRAFFIC CONTROL BID ITEM FOR WORK HOURS AND CONDITIONS. CONSTRUCTION NOTES: 10 REMOVE EX SD PIPE, ENLARGE OPENING AS NEEDED FOR NEW PIPE. U POTHOLE TO IDENTIFY UTILITY DEPTH, POTENTIAL CONFLICTS. U RESTORE CURB, GUTTER, SIDEWALK PER CITY DETAIL DRAWINGS. ADJUST SIDEWALK AND TYPE 2A RAMP AS NEEDED TO MATCH EXISTING. ® TESC PROTECTION: CATCH BASIN PROTECTION, FILTER FABRIC FENCING, ETC. SEE STD DETAILS 214, 216.2, 216.3. INSTALL FILTER FABRIC FENCE IN FRONT OF CONSTRUCTION AREA. PUMP WATER AROUND FILTER FABRIC AND CULVERT AS NEEDED. O5 PROVIDE TEMP STORM WATER BYPASS FOR EX 24" PIPE DURING CONSTRUCTION. TYPICAL TRENCH BEDDING AND BACKFILL (NTS) TRENCH EXCAVATION PAY LIMIT 5'-0" MAXIMUM SEE DETAIL FOR PAVEMENT PATCH BACKFILL MATERIAL WSDOT SECTION 9-03.19 BANK RUN GRAVEL, OR NATIVE MATERIAL IF IT MEETS SPECS. PIPE ZONE MATERIAL WSDOT 2006 SECTION 9-03.12(3) GRAVEL BACKFILL FOR PIPE ZONE BEDDING NEW UTILITY PIPE EXCAVATION OF UNSUITABLE SOIL IF NEEDED) DEPTH AS APPROVED BY ENGINEER BACKFILL WITH FOUNDATION MATERIAL MEETING WSDOT SECTION 9-13.6 QUARRY SPALLS NOTES 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT PIPE ZONE MATERIAL TO 95% MAXIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY. 4. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE THAT THE FLOW LINE IS MAINTAINED. D=3 14603 R CITY 0E RENTON Planning/Building/Public Works Dept. AS -BUILT SURVEY BY: Michael R. Dewitt, PLS #36795, AS -BUILT Redline Plans Stamped on 10/5/2010 10-21-10 UNION AVE NE / NE 5th CT FELDBOOK: PAGE: STORM SYSTEM REPAIR DRAWING NO: 3 SHEET: OF: - 5 D-3146