Loading...
HomeMy WebLinkAboutSWP2703149.280 l­_ cn 5'-0" cf) I ;a I -- 00 - 11 - d OFFSET INLET POINT ALT INLET LOCATION, SEE PI nt.lc GENERAL NOTES: 1. PROVIDE WATER TIGHT SEALS AT ALL JOINTS. 2. STRUCTURAL REINFORCING SHALL BE PER SPECIFICATION SECTION 7-20. 3. INCREASE THICKNESS OF QUARRY SPALL LAYER TO 2' FOR VAULTS P-1 AND 10-1. 4. LOCATE ACCESS GRATES AND COVERS AT SUMP LOW -POINTS PER GROUT DETAIL, THIS SHEET, AND AS INDICATED ON THE PLAN SHEETS. CIRCULAR ADJUSTMENT FINISHED SECTION F GRADE ELEV I INLET IE d a NON -POROUS, NON -SHRINKING GROUT AROUND PIPE - LADDER, TYP SEE CITY OF RENTON STD PLAN B034 GEOTEXTILE FABRIC FOR SOIL STABILIZATION PER SPECIFICATION SECTION 9-33.2, TABLE 3, TUCKED UNDER VAULT FOOTPRINT BY 18". WHPT(Iflic 12100 NE 195th St, Ste 300 Bothell, WA 98011 s�ao 1°' \L 9 \' ° \04" °'I'9 425-951-4800 Fax 425-951-4808 www.whpacific.com L=(SEE TABLE) 5'x10' ACCESS GRATE (H25 RATED) AI/lTr A A AIn C VAULT PLAN NOT TO SCALE GRATE OPENING 5'-0" x 10'-0" WQ DESIGN WS VAULT FLOOR ALT OUTLET LOCATION, SEE PLANS PRECAST RISER SECTION ja 6" LAYER OF COMPACTED CSBC 1' MIN LAYER OF 2" TO 4" QUARRY SPALLS, SEE NOTE 3 SECTION A -A NOT TO SCALE BHC Consultants, LLC 720 Third Avenue, Suite 1200 Seattle, Washington 98104-1820 206.505.3400 206.505.3406 (fax) www.bhcconsultants.com NO. REVISION OFFSET POI NT - ,a ia 5'-0" OUTLET IE GROUT 2" MIN AT LOWEST POINT z 0 cn 0 Z W IT N j' TYP i A A a OUTLET ACCESS COVER, TYP MANHOLE RING AND LOCKING COVER PER WSDOT STD PLAN B-25, TYP 2' AT LOWEST POINT WATER QUALITY VAULT TABLE VAULT NAME / N0. START STATION, OFFSET END STATION, OFFSET INSIDE DIMENSION (LxWxH) FINISH GRADE ELEV * VAULT FLOOR ELEV INLET IE OUTLET IE LOGAN AVE N L-1 146+95.00, C/L 147+74.00, C/L 79'x8'x10.5' 31.36 18.19 24.09 26.19 L-2 L-3 43+70.14, 34.50' RT 45+81.14, 34.50' RT 211'x8'x10.5' 29.28 '16.15 21.52 24.15 51 +71.38, 33.23' RT 53+67.27, 33.97' RT 189'x8'x10.5' 29.29 15.63 20.47 23.63 L-4 64+43.90, 52.0' RT 65+71.19, 52.0' RT 121 'x8'x 10.5' 27.80 14.67 20.67 22.67 PARK AVE N P-1 35+67.24, 3.9' RT 36+ 1 1.24, 3.9' RT 44'x8'x 10.5' 29.74 17.05 25.05 25.31 N 8TH ST 8-1 69+95.00, 0.5' RT 70+78.00, 0.5' RT 83'x8'x10.5' 28.89 15.76 21.76 23.76 N 10TH ST 10-1 63+00.00, C/L 63+89.00, C/L 89'x8'x10.5' 30.44 17.31 22.81 25.31 10-2 58+15.00, C/L 58+99.00, C/L 84'x8'x10.5' 28.20 15.18 23.18 23.41 * MEASURED AT POINT OF MINIMUM COVER. FINISH GRADE ELE FOR BACKFILL REQUIREMENT`. SEE DETAIL 1 DWG U29 - o 00 VAULT FLOOR ELEV D 1 JCS 3.12.10 MS V SURVEYEcSR DESIGNED: - DN DRAWN: CAD CHECKED: LCA BY DATE APPR APPROVED: LCA �iv SECTION B-B 4928 NOT TO SCALE SCALE: HORIZONTAL: NAD 1983/1991 �� CITY 0 F AS SHOWN �� RENTON ONE INCH AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH v� SCALE ACCORDINGLY L FOR "L" LESS THAN 50' EQ EQ FOR I" AT 50' TO 100' EQ t EQ EQ FOR "L" AT 100' TO 150' O O O O EQ EQ EQ EQ FOR "L" GREATER THAN 150' GROUT DETAIL NOT TO SCALE RECORD DRA WINGS PREPARED BY WHPACIFIC, FEBRUARY 2010, BASED ON CONTRACTOR RECORDS. CITY OF RENTON SOUTH LAKE WASHINGTON ROADWAY IMPROVEMENTS WET VAULT DETAILS A 10 0035524 sc i s T E����z'ww SIONAL EXPIRES 06/06/07 DATE: 4/17/06 FIELDBOOK: PAGE: DRAWING NO: SD26 SHEET: OF: 83 205 z >z ay >Z Illit 1 He o� 1 d� w *Eli aPO b� cz