HomeMy WebLinkAboutSWP2703149.73
0
0
V)
I
CL
t0
M
�o
M
z
J
i {I
i
6
j LOGAN AVE
N STA. 58+ 10.20= I�
�
I N 10TH ST
STA. 49+96.90 1 II
0
g:
%iLu
I
i
1
n
I
Z
SDMH #L-15, TYPE 2-84
STA 56+65, 49.12' RT
I SDMH L- 16, TYPE 2-
`
72 I
rn
SDMH #L-14, TYPE 2-72",
I STA 58+ 10.31 , 46.42'
RT I
W/o SUMP
�►
--1
STA 56+26.25, 27.89' RT
LOC%m AVE. N.
4
1 57+00
I I
58+00 s { { 59+0
CT�
56 + 00 _ —
— --�- — I — —+
— — - — — - —
CP
TICE�- -
.------- ----- — — — —
O
0
cn
EX 96" METRO SEWER
CONSTRUCTION C/L
Lei
1 =
0 0
LLJ
O �_ _ - ___--{--------------- _ - -�-_� I TCE - - O
R/W O
$„ _ - 1 -
j 1 _.
- - AL ,.I cora p _ _
� \ I POWER � � 1
J► SO 48" SID '
s
-1
4„ SO
o .
O
18" SID —
R/W — -- 3
TCE
CB #L-16,
TYPE 2-48"STA
-OCF
54 44'6 RT00I PRIVATE MANHOLE "I/' \
56+58.88, 73.27 RT
LO
0
0
w
-1117
w
0
w
z
J
S
U
Q
e,
cn
� N
N @
30
20
10
r� 0
O-) 00
O O
1 I"7
-50
WHPacific
12100 NE 195th St, Ste 300
Bothell, WA 98011
425-951-4800 Fax 425-951-4808
www.whpacific.com
O
O
CO
rn I
J
w O
_ �
m
Q
I:2
U
0 0
m
Iw I
cnz
z cnI�-
0o I z z o
� 100 00100
N
Ln Ln
00 co co
M M 00
N N N N
w w wlw
00
C0
0
n
56+00
z_
O
+I
w
O
a_
0000
F--
U
z
Q
�00
= N
0
, Ln
�
a_ N
X
W
N O-
C7 Fy
X
w
0�
I— w
20 LF - 24" SID
S=0.2% `
SDMH L-17, TYPE 2-48"
STA 58+ 10.20, 56.5' RT 'I + j 1�
(SEE SHEET
SD15)
LOGAN AVE
N STA. 58+ 10.20=
N 10TH ST
STA. 49 +9 6.60
ELEV=31.56
LO
-
EXISTING GROUND
<
@ CONSTRUCTION C/L
o
I
-J -j
Cf) 00
- FINISHED GRADE
@ CONSTRUCTION C/L
bi_
o o-
N N
LL
(n (n
of
w r-
I I ► � —
-.i---------------------1�'
0 o
------------------
I I I i
203 LF - 18" SD S=0.20% 1
46 LF-48" SD
S=0.07%
143 LF - 48 SID S=0.072%
w L:��34"x24"CMP ARCH
FL=20.62
z
I U
Q
w CL
�z 12
cn w
z10 Z
x
00 0 �
N 1`0
I I I I EX 96" METRO
N N 1`0 N SEWER
1-01 11 10
ooLno
NIN N N
wIw w w
O _- n Ln 00
00 ( 0
o
n r�
56+50 57+00
- ■ BHC Consultants, LLC
720 Third Avenue, Suite 1200
■ Seattle, Washington 98104-1820
Tel: (206) 505-3400
CONSULTANTS Fax: (206) 505-3406
Formerly a Division of Berryman & Henigar
48„ SD
LLl
12,
_ J - 2
V- �
CB
—R/W Q
TCE
L-17, TYPE 1
STA 59+00, 55.08' RT
zz
00
r' 0)
w w
J ILd
00
U (D
�3: 3:
W Ld
------ _---------------------
0 89 LIF -12" SD (CL 52 DI) I
S=0.20%
----------------
t
285 LF - 48" SD
I
w 0
�
w
w
w
z
F--
V)
�
olz
z
z
-10
00
Ln
N
N
00
00
I
NNNLn
I
I
I
I
I
-
O
Ln
I Ln
1`0
1`0
1`0
r
0
0
N
N
N
N
N
N
Li
w
w
w
wI1I
cn l
H
�I
0
0
S=0.072%
— O
-- -- — — Q
— 230 LF - 15" SD
S=0.20%
L-i
Ln
0-)
Ln
Ln
LO
0-)
O
0 0
57+50
58+00
58+50
59+00
59+50
1
RECORD
DRAWING
HCS
3.12.10
MSV
SURVEYED:
CSR
SCALE:
H. 1 "=20'
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DESIGNED:
DJR
V: 1 "=5'
-
DRAWN:
PLS
ONE INCH
_
CHECKED:
LCA
AT FULL SCALE
IF NOT ONE INCH
NO.
REVISION
BY
DATE
A P P R
SCALE ACCORDINGLY
APPROVED:
LCA
- - - - - - - _
Ln
W
2U W
L)
O
O
+
O
(0
Q
10 V)
W
Z
J
U
Q
N
0
n
60
CITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE
20 0 10 20 40
(FEET)
CONSTRUCTION NOTES
1. PROTECT EXISTING BOEING UTILITY TO
REMAIN.
2. DEMOLISH CB TO MIN 3' BELOW FINAL
GRADE AND FILL REMAINING STRUCTURE
WITH CONCRETE CDF, OR COMPACTED
SAND.
3. VERIFY DEPTH TO ADJACENT EXISTING
UTILITIES (P, W) PRIOR TO CONSTRUCTION
OF 18" SD STUBOUT. NOTIFY ENGINEER
OF ANY POTENTIAL CONFLICTS.
4. PROTECT EXISTING METRO UTILITY TO
REMAIN.
GENERAL NOTES:
1. FOR WATER, SEWER AND JOINT TRENCH
LOCATIONS, SEE UTILITY DWGS U00-U25.
2. OPEN CURB FACE (OCF) CATCH BASINS
SHALL BE PER WSDOT STD PLAN B-2e
WITH BI-DIRECTIONAL VANED GRATE.
3. FOR PIPE DEMOLITION, SEE DETAIL 3
DWG U29 AND SPECIFICATIONS.
4. EXISTING UTILITIES NOT INDICATED AS
REMAINING SHALL BE CONSIDERED
ABANDONED OR REMOVED AS NECESSARY.
LEGEND:
JOINT TRENCH, SEE SHEETS
U49-U52 FOR PLAN &
SECTIONS.
D 3 14907
RECORD DRAWINGS
PREPARED BY WHPACIFIC,
FEBRUARY 2010, BASED
ON CONTRACTOR RECORDS.
NtiASg1�C
0035524
FC1 STE�� S
SSIONAL ECG
EXPIRES 06/06/07
CITY OF RENTON
SOUTH LAKE WASHINGTON
ROADWAY IMPROVEMENTS
STORM DRAINAGE PLAN AND PROFILE
++ LOGAN AVE. N. STA. 55+50 TO STA. 60+00
OFWA
J
408�9 �
IST
SIONAL
EXPIRES 04/26/07
4/17/06
FIELDBOOK:
PAGE:
DRAWING NO:
SD06
SHEET: OF:
62 205
z
rz
x0
az
v
on
N
o ZO C-1
a
d�
~
�o
cz
y
CAI