Loading...
HomeMy WebLinkAboutWTR2703155.10 ry J I (D N N / 0 0 / z 0 V) w fn 0 r� / r 0 N / N i w Q z W L0 O 0 N z 0 W L.I J 0 w in 11111711iiIiiiiiis- 40 0 40 80 SCALE IN FEET NE 15-23-5 SITE DEVELOPMENT PLAN & TOPOGRAPHIC SURVEY PROVIDED BY DODDS CONSULTING ENGINEERS NOTE: CAR WASH & ESPRESSO STAND SHALL BE SERVED BY 1 1/2" SERVICE TO CONVENIE[f"E STORE. NOTE: SERVICE LINE TO CAR WASH WILL REQUIRE A REDUCED PRESSURE BACKFLOW ASSY. APPROVED BY DOH. NOTE: PRESSURE REDUCING VALVES REQUIRED DOWNSTREAM OF ALL NEW METERS NE 4TH ST (SE 128TH ST) MAIN & HYDRANT CONNECTIONS SEE DETAIL 1 THIS SHEET CUT -IN 1-12"x8" TEE (FLxMJ) 2-8" DI SPOOL:2 LF 2-12" MJ SLEEVE 1-8" GV (FL) 1-8" 45' VERT BEND: FLxMJ 1-8" DI SPOOL: 2 LF 1-8" 45' VERT BEND: MJxMJ 1-8"x6" TEE (MJxFL) 1-6" GV (FLxMJ) 1 —51/4" MVO STD. FH ASSY. �G EX.12"DI T EX.12"DI W ---- PROPOSED 12"SD= �T NE 4TH ST —i — — CB (SE 128TH ST) PROPERTY LINE - 1` r'�h._j t - - EX WV EX. WV rT'---------------------- EX.12"CI W-- N — — — — — — — - -I---_-EX.SS---------- --- �Hl"Bell MH" o----------EX.SS---------------------- N o d- Ex.wv — — — — — ——G— I - --Ex.12"DI w- -� - - -G -G - ---- --- 2"DI W- ---- - 7 G �� G T _o- WET TAP EX. 12"DI WM w/ 1-12"x6" TAP. TEE (LONG SLEEVE EPDXY COATED STL. (FLxFL) 1-6" GV (FLxMJ) 1 —51/4" MVO STD. FH ASSY. w/11'-6" SPOOL WET TAP EX. 12" DI WM w/ -� 1-12"x8" TAP. TEE (LONG SLEEVE EPDXY COATED STL. (FLxFL) 1-8" GV (FLxMJ) W .-. Z LU 164 >W Q U_ 110 w 3 Traff T {tr-----EX.12 DI W----- — , L p g TS - "Bell MH" �S I PROPOSED "wC°M" �� MH ESSO SIGN o �, ' - SIGN - y EX. WATER METER IISTAND I Cn = DRA/N I / ^I CONCRETE SWALE II II 0!-- — II 11'-8"D DETAIL � NOT TO SCALE o-10' PERM. ESMT. 15-23- 5 w I NI II (TYP.) 10 o o gas ALL ONS ESMTS. $= o I X. I o f R� UTILITY VAULT CO. II _ - meter Q W �B OIL/WATER SEPARATOR b °° ° N Temporary CUT &CAP GALV. 1" PIPE AT PROPERTY LINE a I p � � Structure o 00 0 I EX. DRAINFIELD PR PO ED"SS I aSEPTIC - 188'-8"DI 0024 TANK PROPOSED EXISTING I 10 x12' P R NR I HOUSE I I'' o � I � p RETAIL „ I 5403 I� 0 1 # ESMT. I 1��F°ASS RESTAURA # 1 WATER METER IIH I� I� IN 5 x 5 PERM. ESMT. -- II PROPOSED II g'� I I 1 1/2" WATER I T€F-- CONVENIENCE OVER i SD II 1-8"45' �ND (MO' J) OVER SEWER 25'f I I IN 5'x5' PER - - STORE \�'II I ESMT. u _ _ 16'-8"DI i 1 � 5, �\ UNDER SD II 9'-8"DI 131'-8"DI ��\ 7 ± 1-8"x8" TEE (MJxMJ) 1-8" MJ PLUG -r- IH \\ 1" WATER METER T5— _ 149 -8 DI — - , IN 5'x 18' PERM. ESMT. L I I 10' PERM. t OVER SEWER ESM T. I i _j _Z w (TYP.) 1 JL8"45' BEND (MJxMJ) - - �� 11 w �,1 z Cyl PROPOSED z CAR o' PRODUCE STORE 0021 P WASH Lid - - TV 21PFi `I I CV 13"cedar M CV ® x=Kx PROPOSED 12"7D ISM _ WOOD FENCE 1-8"x6" TEE (MJxFL) Al J 1-6" GV (FLxMJ) III 30' 30,11 1-51/4" MVO STD. FH ASSY. I to Q I w/6'-6" SPOOL I log CO IN 10' x10' PERM. ESMT. to x o I� w - / N � o - I ox ILLA56 55 o I 54 I 53 52 % m 0C=NHA f I I :NE 3RD ST EX.F1, EX.8"DI W -- —IEX.WV'S —— — — — — — — — — — — EX.8"DI W--------------- _ r II I 1 � rA 51 X.WV'S 50 TRACT "A" NATER SERVICE THESE RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY WD # 90. ROTH HILL ENGINEERING PARTNERS, LLC HAS NOT VERIFIED THE ACCURACY AND/ OR COMPLETENESS OF INFORMATION PROVIDED BY OTHERS AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS. REV�'_OD TO INDICATE CONS 1 � ,'IJCTION RECORDS FIELD REP: LESTER PIELE/PHIL VAN EARWAGE REVISED BY: BRIAN WOLF DATE: SEPTEMBER 14, 2004 CONTRACTOR: GREEN RIVER 8"D.I. PIPE: 503 L.F. (CL52) / GRIFFIN F.HYDRANTS: M&H VALVES: KENNEDY FITTINGS: TYLER ORIGINAL DWGS: SHEETS 2-3 NOT A PART OF CRD SET CRD SHEET 1 OF 1 WATER DISTRICT NO. 90 APPROVED `�� (/I l CONSTRUCTION Ajlll� I DRAWINGS: DATE. GENERAL NOTES: 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARD DETAILS OF WATER DISTRICT NO. 90. THE SPECIFICATIONS AND STANDARD DETAILS MAY BE A SEPARATE SET OF DOCUMENTS, APART FROM THESE DRAWINGS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE OWNER SHALL FURNISH THE ENGINEER WITH A COPY OF THE APPROVED ROAD GRADE, ROAD CROSS SECTION, AND DRAINAGE PLAN PRIOR TO ANY WATERMAIN CONSTRUCTION. 3. EXISTING UTILITIES ARE SHOWN FROM THE BEST AVAILABLE INFORMATION AND NO GUARANTEE IS MADE AS TO THE EXACT SIZE, TYPE, LOCATION, OR DEPTHS. 4. PRIOR TO CONSTRUCTION OF ANY WATERMAINS, THE STREETS AND LOTS SHALL BE STAKED AND THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES. 5. ALL WORK IN STREET RIGHT-OF-WAY TO BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE ROAD ENGINEER WITH JURISDICTION - EITHER KING COUNTY OR THE CITY OF RENTON. 6. WATERMAIN SHALL PASS UNDER STORM SEWER WHEN REQUIRED TO MAINTAIN 3-FOOT MINIMUM COVER OVER TOP OF WATERMAIN 8-INCH AND SMALLER (4- FOOT MINIMUM FOR LARGER THAN 8-INCH PIPE). THERE SHALL BE NOT LESS THAN A 6-INCH CUSHION BETWEEN THE WATERMAIN AND THE STORM SEWER. 7. WATER SERVICES SHALL BE LOCATED AT LEAST 5 FEET FROM POWER VAULTS HAND HOLES AND/OR LIGHT STANDARDS. SERVICES SHALL BE INSTALLED BY CONTRACTOR & WILL BE LOCATED BY MUTUAL AGREEMENT BETWEEN OWNER, DISTRICT, AND OTHER UTILITY COMPANIES. 8. FOLLOWING WATERMAIN CONSTRUCTION, ANY REVISION OF ROADWAY OR EASEMENT GRADES REQUIRES THE MAINS TO BE RECONSTRUCTED BY THE OWNER TO CONFORM TO THE SPECIFICATIONS OF WATER DISTRICT No. 90. ALL ADDED COSTS OF INSPECTIONS FOR SUCH REVISIONS WILL BE CHARGED TO THE OWNER IN ADDITION TO THE STANDARD CHARGES, AND SHALL BE PAID BEFORE ACCEPTANCE BY WATER DISTRICT No. 90. 9. WATER SERVICE CONNECTION DETAILS: A. 2" x 4" WOOD MARKER PAINTED BLUE AND IMPRINTED WITH "WATER" IN BLACK LETTERS SHALL BE PLACED AT EACH ANGLE STOP LOCATION WITH A MINIMUM OF 18" OF THE MARKER EXPOSED. B. PAINT SERVICE LOCATION ON CURB WITH COLOR AS DIRECTED BY THE ENGINEER. C. PROPERTY CORNERS SHALL BE PINNED AND THERE SHALL BE A REFERENCE TACK PLACED IN THE CURB OR EDGE OF ASPHALT. 10. THERE SHALL BE A MINIMUM OF 10-FOOT HORIZONTAL SEPARATION BETWEEN WATERMAINS AND SANITARY SEWERS. VERTICAL SEPARATION SHALL BE PER THE DEPT. OF ECOLOGY CRITERIA FOR SEWAGE WORKS DESIGN MANUAL. SHEET INDEX SHT. NO. DESCRIPTION 1 WATER PLAN 2 STANDARD WATER DETAILS 3 CONSTRUCTION PROVISIONS WIM- 3I550/ z Q� a SE 121ST ST_, j D I -- - r- SE1122ND ST — w w w > J z ( n N S I � SE 128TH ST1 a --- - -,I IF SE 124TH ST w w al IQ O I w wl Q =il ---- --- - SE 124TH'', wl w > Q1 I �I N I I1 OoPROJECT SITE SE 128TH ST -- - A�_ - - - - - - SE 132ND S -- - - - - - SEr 1 32ND ST SE 133RD T{ > ai a 1 33RD ST s > w = 1 -- Q Q w > `0_— > a SE 134TH STI o z a - I' _ T a -- SE 135TH ST ~ _ST - --- - !SE 1361H ST w� 1 VALVE CLOSED a 3 SE 137 -_ I— z N 0 O H 00 N L'i EX0 o _ Y Z �0- za Q V) w m 4 Q. O C) � Q U U o 0 J 4t CD 00 J W M Z o Y > o a� ¢ C6 0) � 00 0 4-. _ :3L6 N O O U i Z a o ILO a)U m I ao c:: I� Y Qi � IIIIIIIIII■ � c cn - - w o 0 do � o z a W � — o II 2 W N o Q Ld 0 O Z Z 0 U) LLI ZU�� U) 0 Lij U�?F_ U l♦ nJ V Q Q Z Z Uj < U C� Q BASE MAP t_ SHEET 1 OF 3 DRAWING E2.015 SCANNI:n APR 2 2 4" r& - 87— $/%f r VICINITY MAP t , ! a �"i 5--el e /