HomeMy WebLinkAboutWTR2703157.6L
WATERMAIN ROFILE AND DETAILS
o
Y Z
O O
0 3 r
w 1 < _
v a o (n
J
�
to
z
H
w
Q
z w
U
o
w
G Q
O
U
v
w
J
1Ecc0m
O�wO
z
(L
z0
J
Q
U
Q
>
co
�
-,
w
s./
Q
O
ul
ul
Lil
L_
++ O
�v
o
rr
rn
O
o�
E-4
Q
E.. 4 ram,
W
d
H
c °
W
v
•n
m E
���
`N
o
a_c
j
c p°,
0
w
0
w
0
Y
w
>
(n
z
w
O
z
O
U
o
4
EL
m
m
m
m
O'
Y
Y
Y
Y
Q
0
0
0
o
ro
W
o
Q
M
N
N
C>
x
1\
m
m
m
ml
V)
Z'.
0
0
z
z
z
2
LEI
Ld
W
Q
Z
3
0
U1a
U
O
0
Q
of
rn
LL.I
o
U
U
U
a
W
W
W
W
a
a
a
a
m
LLJ
m
W
0
Lu
m
Ld
in
Ln
(7)
m
E
au.
m
cr
w
z
LLJ
LL
CV
Z
EXISTING WATER LW EXISW WATER LINE
PLAN VIEW
TESTING DETAIL FINAL CONNECTION DETAIL
is FT
NEW WATER LNME NEW WATER LNIE
SEE NOTES SEE NOTES
VERTICAL CROSS(MAd fL) FOR POLYPNOW
ONE AM FLANGE ON TOP W FN 2-TAP t 21PLUG AFTER ALL TEST MMa CLEANING BY POLYPIG AND DLSINFECTAW.
ONE BEND FLANGE ON BOTTOIM REMOVE TEAIR BLOCK At BLOW -OFF R CONILECT
ONE (MN) PLUG WITH 2- TAP t 2- TEMPORARY BLOW -OFF wnn SLEEVE (AN) B &I. sPoms
TEMPORARY BLOCK FNWL COANr XTM BY CITY FORCES
CUT -IN (BY CITY FORCES)
TEE (FLxFL) W/ CONC. BLOCK
3- GATE VALVES (FLxMJ)
2- SOLID SLEEVES (MJ) OR RO-MAC COUPLNMGS
1- PLUG MJ)/ W 2'TAP i TEMP. BLOW -OFF
TEAR' BLOCK
EXISTING WATER LINE EX67M WATER LINE
NOTES
CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL
AND VERTICAL ALWAIM'NT OF EXISTING LINE OR STUB AND
SHALL START lAYNMG THE NEW LME AT THE SANE HORIZONTAL
AAW VERnC4L ALK NT OF THE EXISiNMG STUB
OW FORCES WILL PERFORM THE FINAL CONIWCIION FROM TIff
NEW IMF TO THE EXISW STUB WTW D.I. SLEEVE AND D.I. SPOOL
CITY OF RENTON, WATER CONNECTION DETAIL
e3 VALVES CUT -IN INSTALLATION
C NOT TO SCALE
`TEMPORARY 2" GALVANIZED
PIPE AND 2" GATE VALVE
FINISHED GRADE ELEVATION
3 FT MIN. COVER (10-INCH DIAMETER AND UNDER)
4 FT MIN. COVER (12-INCH DIAMETER AND OVER)
NEW WATER MAIN POLYPIG
INSTALL 2" PLUG ON
TOP BLIND FLANGE
AFTER REMOVAL OF POLYPIG
:a
a •:
VERTICAL CROSS FOR POLYPIGGING STATION:
SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE
VERTICAL CROSS (MJ X FL)
ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP B 2" TEMPORARY BLOW -OFF ASSEMBLY
(REMOVE BLOW -OFT ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG")
ONE BLIND FLANGE ON BOTTOM OF CROSS
ONE PLUG (MJ) ON END OF CROSS
CONCRETE BLOCKING
ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE
DISINFECTION OF NEW WATER MAIN
CITY OF RENTON, WATER MAIN POLYPIGGING STATION
eVERTICAL CROSS FOR POLYPIGGING
C NOT TO SCALE
SCALE: HORIZONTAL 1 "=40' VERTICAL 1 "=5'
1- MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING
(WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY
SHALL NOT BE MORE THAN 50 FEET TO BUILDING)
2- BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER
3- CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM)
ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS
AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS.
4- POST -INDICATOR VALVE (MJ) WITH TAMPER SWITCH
5- 2-90' BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL
6- 18" LONG SPOOL (FL x PE)
7- FLANGE COUPLING ADAPTOR
8- APPROVED DDCVA ON MAIN LINE /N HORIZONTAL POSITION ONLY.
(PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES)
BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND
NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE
SUPPORT COLUMNS UNDER DDCVA
9- O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES.
ADD WIRING /N ACCORDANCE WITH L & /
10- METERED 514 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 314 INCH
'INVENSYS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED WITH A REMOTE
READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL.
1 f - SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP /N VAULT
12- 4 "x 4" x 6' BULL, ELBOW, THREADED
13- UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN
50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT.
AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED
SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY
TESTER. TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY
ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE.
INSTALL BRASS PLUGS AT ALL TEST COCKS.
CITY OWNED
AND MAINTAINED PRIVATELY OWNED AND MAINTAINED
MAXIMUM PIPE LENGTH FROM PROPERTY LINE
TO DDCVA MUST NOT EXCEED 50 FEET
4 CONCRETE BOLLARDS
i"T �- 5 FT. MAX.
r
A
W Z
Z
J P4
Z
W
W �
� W
O ¢ J
rY
a W 3
o �
j
CITY OF RENTON, INSIDE BUILDING INSTALLATION FOR
c 3 INCH AND LARGER DETECTOR DOUBLE CHECK VALVE ASSEMBLY
NOT TO SCALE
TESTING DETAIL
.Lo rl
TAPPING TEE (MJxFL)
TAPPING GATE VALVE (FL XMJ)
TEMPORARY PLUG (MJ) WITH 2-INCH TAP
AND 2-INCH BLOW -OFF ASSEMBLY
CONCRETE BLOCKING
NEW D.l. WATER LINE
VERTICAL CROSS(MJxFL) FOR POLYPIGG/NG
1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG
1-BLIND FLANGE ON BOTTOM
1-PLUG(MJ) WITH 2-TAP & 2" BLOW -OFF
TEMPORARY BLOCK
NOTES.
1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY -
COATED STEEL.
2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES.
TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN.
3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE
4. WET -TAP SHALL BE DONE ONLY BY CITY -APPROVED CONTRACTORS
CITY OF RENTON
c WATER LINE CONNECTION DETAIL
NOT TO SCALE
FINAL CONNECTION DETAIL
Al
BUILDING WALL
PERIMETERS OF MIN/MUM CLEARANCES TO BE
PAINTED ON FLOOR IN WHITE ENAMEL PAINT
x
z
STRIPE, WITH 2 INCH STENCILED BLACK LETTERS
TO SAY. "DO NOT BLOCK ACCESS"
N 5
DDCVA MUST BE INSTALLED IMMEDIATELY AFTER
© O
7
PIPE PENETRATION THROUGH BUILDING FLOOR SLAB.
ROOM /N WHICH DDCVA /S LOCATED SHALL:
O
y
I,,,I
A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM.
0 1 O
v
a
S. HAVE A HEATING SYSTEM (40- F MIN. TEMP.) NO HEAT TAPE
C. NOT BE USED FOR STORAGE AROUND THE DDCVA
®
HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs.
M
beD.
A RIGHT -OF -ENTRY AGREEMENT MUST BE GRANTED TO THE
m
CITY OF RENTON FOR INSPECTION OF THE DDCVA
OAND
METER.
Oz
SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA
w
MUST BE SUBMITTED TO RENTON FIRE PREVENTION DEPARTMENT FOR
�
0
0
REVIEW AND APPROVAL.
4 INC y 48 INCH
A SEPARATE FIRE SPRINKLER PERMIST IS REQUIRED.
NEW D.I. WATER LINE
W
H
}
to
W
J
Y
Z_
ir
IL
In
W
L6
0
I-
24 INCH MIN/MU
36 INCH MAX/ML
ELEVATION VIEW OF DDCVA
w 401b 3&*!v7o6
By:
By:
AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING By:
AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF
AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS
FINAL CONNECTION BY CITY FORCES By:
13,4
S
O� i
\
Y
4
REVISED PER CITY REVIEW COMMENTS
BSW
AS
3/17/04
�v
3
REVISED PER CITY REVIEW COMMENTS
BSW
AS
3/11 /04
�F 25672\� ��
SIONAL
?
REVISED PER CITY REVIEW COMMENTS
BSW
AS
2/12/04
ADDED FIRELINE TO BUILDING
BW
AS
1/19/04
EXPIRES 9/23/05
No.
REVISION
BY
APPR.
DATE
DESIGNED
DRAWN
CHECKED
APPROVED
J
cr
w
z
w
w
o
U
w
a
�
u
w
_
J
a:�
O �
0
w O
65
cr
U
w
z
„i
Q
Q
oc
w
w
Q
Q
J
O
O
O
UJ
J
J
w
2
I
r
�
0
o
w
N
N
z
V
.,;
Q
x
(3)
x
Z
QO
�ww"'
E
w
/
Q
J
n
O
�
z
r_
0
O=av
L
1'�/—/��
L
tE
w
U
v-)
0-
r7
O
U
u-
r
O
CD
N
Oco
a>
E
O0
LL
a�
LLI
=
I—
o U
Z_ j
�
O
Z �
N
D
g
O
JLLI
O
Z
X
Q Z
W
LLI
Q
N
M
N
ILL.
N
Z
O
N
00
Z_ —
Q
O)
c0
00
Of Z
Ld
Q
�-
Z w
Ln
Ln
C7 Z
Ld
L0
L0
LEI
o
co
Ld
N
N
a
Y
.�..
��i
0 V)
a
Q)
Date —11
01
CITY OF RENTON
DEPARTMENT OF Pl1RLIC WORKS
E
O
z
In
O
u j
°
7303
DATE / /
FILE NO.
SCALE 1 "=40'
FIELD BOOK PAGE_
C20 25
DIRECTOR OF PUBLIC WORKS