Loading...
HomeMy WebLinkAboutWTR2703163.1r W D s STA 8+424-11'LT L 8" TEE(FL) 8" PLUG(FL 8" GV(FLxMJ) 8" VERT CROSS (FL) PORTION OF THE N W 1/4 OF THE SE 1/4 OF SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, CITY OF RENTON, STATE OF WASHINGTON W. m A I rid -. 32.00' _ THE EXISTING HOUSE ON LOT 10 KILL HAVE A NEW WA TER METER �; N�~ 09 4 P� - W - 2+ - . PER THE PLANS FOR ROSE SHORT 1+o2-8'RT PLAT &THE NEW 6" WATER MAIN 6 " PLUG TAPPED 2" 1+81 1-%'RT f 35 f INS TALLA 770N. 2 BLOW OFF ASSEMBLY 6" 45' BEND(MJ) CONC. BLOCKING CONC. BLOCKING EX ACCESS & UTILITIES 26LF 6 DI lv EASEMENT REC NOS. CL 52 O f f 9205131423 & R. O. S. f `f 9108269012 2+14.6-6.6'RT ^ f `) o f § f 6" 45' BEND MJ /` CONC. BLOCKING `3 O �, 3 6a I f �► 14ti ' ? ;° 135LF 6" DI (!} _ ` Ia O FILL AND COMPACT THE ROADWAY PRISM 0' f 1 p I TO FINISH GRADE PRIOR TO EXCA VA 77ON f f " t 0 R= 360.00 L=52.60 Tan = 26.35 Del ta= 08 22'19 //�� 77th FOR INSTALLA T10N OF WATER MAI� l� I f /� 0) , 14 - _ L A C E N 507 .542 3 13 fLn E 5085.807 f ? I W TER P ._ 2 EX A Z __ EP — -- __ J I I } } METERS W 8 ADAPTOR (FLxMJ) __ NEX WM TO BE REMOVED STA 7+03.2-11 LT-- RELOCATE 70 o CONC BLOCKING 8 x6" 7FE(MJxFL) — — I+ i SEE CONNECTION D TL1 - o EP -- N - - o 6 GV FLxMJ) :-- _ _ _ - - - S 88 09 40 E (PLAT - - t +g 8+00 - f - GONG BLOCKING f 6+00 5+00 MONROE CT NE 7+00 ---- ~-- -__ ``gip► _ Ss r STA 4+79-40RT - - - - -- r_ 100LF 8" DO 277.25' (P A T) -- -- NEW INTX NE 17TH PL 1 LF 8"DI ' NEW FH ASSEM€� Y��" 276.97 ;- X/ST 8" W (W-2030) � � 2,2'LF 8 Dl p _ (MEAS) l 5+00 7_ — 272LF 8"Dl CL52 EX.6"C/TOABANDOND _ - l _ � -- — —------- -- -�-'/_ j EP N — �7 4 OO EXIST 8 x6" REDUCER ! * __ __ _. _._ __. —EP— 21F g�D/ ' N '9900 \� TO BE REMOVED STA PER NE NTX = u / EX. 6" Ci TO ABANDONED �` -- - E \ a e AT MONROE CT NE 5110.52J6 STA 8+4 .4-16'L T ' STA 7+23.8-11 L T , g CONNEC7ON 4 PG. 8" 90BEN (MJ) ' 8 x6" TEE FLxFL ALL TRENCH RESTORA 77ON SHALL BE TO THE RECONNECT EX/S77NG WA TER SERVICES TO c 5.00 \ STA 4+89.00-5.00'L T ( ) - CONC BLO KING �5 ��� L=219. A : 2-8 GV(FLxMJ) CURRENT CITY OD RENTON TRENCH RESTORA T70N NEW WA TER MAIN AFTER 7iE-lN HAS BEEN a 8" SPOOL PIECE 8"X8" TEE(MJXFL) I STA 3+84.3-11 L / Tan=113.66 a i " AND STREET OVERLAY DETAIL. COMPLE7FD. NEW SADDLES AND CORP a 8" RO-M C ADAPTOR(DI-Cl 1-8"GV FLXMJ 1-6 GV(FLxMJ) STA 4+27 3LT 8"x6 TEE MJxFL = r CUT &CAP EXISTING 6" ) 8" VERT CROSS MJx 6" SPOOL PIECE STOPS REQUIRED. 8"-11 1/4' BEND(W) 6" 7FE(FLxMJ) ) to-3728 55 \ cp WATER MAN AFTER TIE-IN " ( 6 RO-MAC ADAPTOR(DI-Cl) CONC. BLOCKING CONC. BLOCKING 8 SOLID SLEEVE CONC BLOCKING 3+72.6- TA 3+62-111 T \ �o CONNEC77 N W/GONG. BLOCKING RECONNECT EX FH 1-8"x6" 7EE(MJxFL) 8 x " 7EE(FL) REMOVE EXISTIN - 1-6" GV(FLxMJ) 8" PLUG(F m 7FE & VALVES, CUT & ALL NEW WATER MAIN SHALL BE 6"-11-114' BEND(MJ) g" VERT. CRO m CAP EXIS77NG 6" WA7FR O $" CL 52 DlP POLY WRAPPED CONC. BLOCKING 8" ADAPTOR(FLxMJ) \ AFTER TIE-IN CONNECT/0 I 1. A RESIDENT/AL FIRE SPRINKLER SYSTEM /S REQUIRED FOR ALL LOTS W THIN THIS PLAT 6" GV(FLxMJ) \ SEE COIVNEC77ON #2 CONC. BLOCKING F 2. THE DEVELOPER MUST VERIFY 7HE MINIMUM SIZE OF DOMESTIC WA7ER METER TO EACH L 0 T WITV A g DETAILS SHEET 13. I FIRE SPRINKLER DESIGN PRIOR TO INSTALLA 77ON OF THE WA 7FR SERVI2-16 CE S7I/B & METER. STA 3+ ND(MJL T J. A SEPARA 7E FIRE SPRINKLER PLAN MUST BE SUBMITTED TO RENTON FIRE DEPARTMENT FOR REVIEW 6" 908ED(MJ) - - CONC BLOCKING I AND PERMIT77NG PRIOR TO l 7HE SPRINKLER SYSTEM. A BACKFLOW PREVEN7FR DEVICE 6 SPOOL PIECE �' DOUBLE CHECK VALVE AS D FOR EACH BUILDING. " o o I o�� �� a �r�� RECOMMENDED M E N D E D 6" RO-MAC ADAPTOR(DI-a) \ _ FOR APPROVAL cur &CAP Ex. 6 MAIN (WEST) As ; AF7FR 77E-IN SEE CONNECTION a H. TO ,3 DETAIL SHT 13 I W W w s O 1 r.) Z INS /(03 04 9 o� of WA skI U �C�� BY DATE sIONAL BY DATE "AS —BUILT" NOTE; "AS EXPIRES 6/22/"07 1-6 d'70 ��,9STEn" BY DATE -BUILT" IS BASED ON A ACTUAL FIELD SURVEY BY TOLIMA ENGINEERS AND INFORMA 77ON SUPPLIED sSIONaL B Y DATE BY CON7RACTOR. EXPIRES 6/22, 6' BY DATE 71 9 1 5SIT,DWG MEN SCANNED OCT 2 8 2005 'Op s r"/_ 3 s e.3 o <1