Loading...
HomeMy WebLinkAboutWTR2703185.3CONCRETE AND REINFORCING STEEL NOTES; 1. ALL CONCRETE WORK MALL BE IN ACCORDANCE WITH THE ACI 301. ACI 318, ACI 336, ASTM A184, ASTM A1B5 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF PSI AT 28 DAYS, UNLESS NOTED OTHTRRWISE. 3. REIN NG STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, ED UNLESS OTHERWISE WELDED WIRE FABRIC SHALL CON ASTM A 185 STEER WIRE FABRIC UNLESS NOTED OTHERWISECES SHALL BE CLASS 'B D ALL HOOKS SHALL BE STANDARD, UNO. THE FOLLOWING MI UM CONCRETE COVER SHALL BE P FOR 4. REINFORCING STEEL LESS SHOWN OTHERWISE ON D NGS: CONCRETE AGAINST EARTH ..... _.3 , CONCRETE TO EARTH OR THEN; 6 AND LARG ........................2 IN. 5 AND S D .........1 1/2 IN. CONCRETE NOT EXPOSED EARTH OR WEATHER OR NOT CAST AGAINST THE GRO SLAB ANO W 3/4 IN. BEAMS AND OLUMNS............1 1/2 IN. 5. A CHAMFER 3/4' SHALL PROVIDED AT ALL ED EDGES OF CONCRETE UNO. IN ACCORDANCE ACI 301 SECTION 4.2.4. 6. INSTALLATION OF EXPANSION/WEDGE ANCHOR, IE PER MANUFACTURER' WRITTEN RECOMMENDED PROCEDURE THE HOR BOLT. DOWEL. OR SWILL CONFORM TO MANUFACTURER'S RECDM DAT10N FOR DEPTH OR AS SHOWN ON THE DRAWINGS. NO R SHALL BE CUT PRIOR ENGINEERING APPROVAL. WHEN DRILLING IN CON EXPANSION BOLTS SHAD. BE PROVIDED BY RAMSET/REDkQ OR AP OVER EQUAL. UNLESS NOTED OTHERWISE. SPECIAL INSPECTIONS, WNCN BRED BY GOVERNING COOLS, SHALL BE PERFORMED IN ORDER TO AIN UFACRIRER'S MAXIMUM ALLOWARE LOADS. CONCRETE AND REINFORCING STEEL NOTES 302 NOTES: 1. ENGINEER SHALL DETERMINE DEPTH 'D' BASED UPON NATIONAL ELECTRICAL CODE. UTILITY REQUIREMENTS OR STATE AND LOCAL CODES, 2. LEAN CONCRETE r/ RED TINTED TOP MAY SE USED IN PLACE OF COMPACTED SAND. FLESHED GRADE OR GROUND COVER, MATCH SLOPE AND THICKNESS TRENCH EXISTING UNDISTURBED SOL OVARY TAPE PACTED BACKFILL D= W/ SATISFACTORY NATIVE OR IMPORTED SOIL w rn —_ _ COMPACTED SAND (SEE NOTE 2) COMPACTED SAND BED (SEE NOTE 2) CONDUITS FOR T849 ELECTRICAL, do ANTENNA SHAPoNG WHERE APPLICABLE 6' (MIN) * CONDUIT SIZE, TYPE, QUANTITY AND SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS DIRECT BURIED CONDUIT DETAILNTS 328 BECHTEL TELECOMMUNICATIONS 12131 113TH AVENUE NE KIRKUWD, WASHINGTON 98034 WTiQ- 27-.?I*r 6 1 5 '25m- hsp1cwa rxaMs wx nom wsrtm �m Is�l t'1 ,mtnmooN Y.- SO SITE NAME: RENTON HILLS SITE #: STTLWASGI7 12603 82ND AVE. SOLRH RENTON, WA 98055 14012' EA. O 19 OF FINAL GRADE SLOPE — AWAY FROM CONCRETE 1' CHAMFER (TYP) 2` ABOVE GRADE OR PAVEMENT �— EXCAVATE AS REQUIRED TO COMPACTED CRUSHED REMOVE VEGETATION & TOPSOf4 STONE OR GRAVEL EXPOSE UNDISTURBED NATURAL (OPTIONAL; THIOKN SUBGRADE # PLACE CRUSHED AS REQUIRED) ENp VIEW STONE AS REQUIRED 1. CONCRETE NOTES SC- DETAIL 302 GRAVEL SHALL SE NATURAL OR CRUSHED STONE ,DO PERCENT PASSING 1 INCH SIEVE 3. NWrEL CABINET SHALL BE PROVIDED WITH OPTIONAL BASE FRAME CONCRETE PAD FOR NORTEL UMTS iBTS CABINET DETAIL NTS — do& WL. Cam me » 3)owlam te') T'-� m3poe a m s;.. u NORTEL UMTS CABINET 14012N 0l FINAL GRADE SLOPE AWAY FROM CONCRETE //—PoCUFTI (DAYTON/ EDGE INSERT 1 TYPE T-3A OR APPROVED EQUAL) (TYP 4 PLCS) I" CHAMFER (TYP) 2` ABOVE CRADE OR PAVEMENT COMPACTED CR ED ~ EXCAVATE AS REQUED M STONE OR G U REMOVE VEGETATION 0 TOPSOIL. (OPTIC ICINESS INSERTS EXPOSE UNDISTURBED NATURAL SUBGRADE do PLACE CRUSHED AS RE RED) END A STONE AS REQUIRED NOTES: 1. FOR CONCRETE NOTES SEE DETAIL 302. 2. GRAVEL SHAD. BE NATURAL OR CRUSHED Wm 100 PERCENT PASSING 1 INCH SIEVE. 3. NORTEL CABINET SHALL BE PROVIDED WITH 0 PRECAST CONCRETE PAD FOR NORTEL UMTS iSTS CABINET DETAIL (12652TUT 4 AT&T AT&T WIRELESS SERVICES, INC. 3 TC Mtn mf>E 25'-0' MINIMUM LEASE AREA 14'-0' CONCRETE PAD AT- UMTS NORTEL s • SSC NOKIA T NOKIA X ABINET r ULT�LTE ULTRASITE�UL 1 t - LE91 J CABINET r CABINET 1 o 1 V-6' FLEARANOFOR ACCYSS IN ST ON 12` 4'-5 11W NORTEL UMTS NOKIA NOKIA RE { CABINET I POWERk CABINET UCABIINNEf �----- I POWER/TELtOUnMR CAN AREA REMOTELY LNOTE: PREFERRED AREA 10'x25' UPON SITE IMUM LEASE AREA WITH GROWTH ND ADJACENT POWER & TELCO Km UIPMENT ON A ROOFTOP WILL REQUIRE A LARGERUPPORT PLATFORM. WW == FM M MEW rE I MUMS AS SHO" . DE GNM BY. )DEC N er: VKJ 2 & LEASE AREA DETAIL 25 77 C 11 13/16 y LT) C UC x o r m Cr) O D �z W Y r r Y O ATBIT WIRELESS -I- NOTES AND DETAILS NORTEL UMTS i8TS (OUTDOOR) 4w mja OAlrwo 7" 24897-612-H I STTLWASGI7-AO2 f3j W -i/$S03 �. SCANNED OCT 0 8 -Z�