HomeMy WebLinkAboutWTR2703185.5RF NOTES: 1. QUANTITIES SHOWN IN O ARE TOTAL QUANTITY. 2. ACTUAL LENGTHS SHALL BE DETERMINED PER SITE CONDITION BY SUBCONTRACTOR. 3. THE DESIGN IS BASED ON RF DATA SHEETS, SIGNED AND APPROVED. 4, RADIO SIGNAL CABLE AND RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC. NFPA 70), CHAPTER 8. 5. ALL SPECIFIED MATERIAL FOR EACH LOCATION (EG., OUTDOORS, INDOORS -OCCUPIED, INDOORS -UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC. 6. RADIO SIGNAL CABLE SHALL BE SUPPORTED AT MINIMUM OF EVERY THREE (3) FEET EXCEPT INSIDE MONOPOLES OR LATTICE TOWERS WHERE CABLE AND CONNECTOR MANUFACTURERS SUPPORT RECOMMENDATIONS SHALL BE FOLLOWED. MANUFACTURER RECOMMENDED CABLE SUPPORT ACCESSORIES SHALL BE USED. 7. THE OUTDOOR CABLE SUPPORT SYSTEM SHALL BE PROVIDED WITH AN ICE SHIELD TO SUPPORT AND PROTECT ANTENNA CABLE RUNS. SEE DETAIL NUMBER 576. 8. DRIP LOOPS SHALL BE REQUIRED ON ALL OUTSIDE CABLES. CABLES SHALL BE SLOPED AWAY FROM THE BUILDING OR OUTDOOR BTS CABINETS TO PREVENT WATER FROM ENTERING THROUGH THE COAXIAL CABLE PORT, 9. ALL FEEDER LINE AND JUMPER CONNECTORS FOR GSM SHALL BE AWS APPROVED 7-16 DIN CABLE CONNECTORS THAT MEET IP68 STANDARDS, 10. WHEN MODIFYING EXISTING TDMA COAXIAL CABLES FOR GSM USE, REMOVE ALL EXISTING N TYPE CONNECTORS WHERE FEASIBLE AND REPLACE WITH NEW 7-16 DIN CONNECTORS. 11, MINIMUM CABLE BENDING RADIUS SHALL BE ADHERED TO IN ACCORDANCE WITH SECTION 6.0 OF DESIGN CRITERIA (DOCUMENT NO. 24623-033-3DR-GET-00001). 12. ALL 7-16 DIN CONNECTORS SHALL BE IP68 RATED. ALL OUTDOOR CONNECTORS AND ALL COAXIAL CABLE SHIELDING GROUND POINTS SHALL BE WEATHERPROOFED IN ACCORDANCE WITH THE FOLLOWING PROCEDURE: START WITH ANDREW WEATHERPROOFING KIT TYPE 221213_ START TAPE APPROXIMATELY 5 INCHES FROM THE CONNECTOR AND WRAP 2 INCHES TOWARD THE CONNECTOR, THEN REVERSE THE TAPE SO THAT THE STICKY SIDE IS UP. TAPE OVER THE CONNECTOR OR SURGE ARRESTOR UNTIL THREE (3) TO FOUR (4) INCHES BEYOND THE CONNECTOR AND REVERSE AGAIN WITH THE STICKY SIDE DOWN FOR ANOTHER INCH OR TWO. ADD THE 8U7YL RUBBER AND FINISH WITH A FINAL LAYER OF ANDREWS TAPE. 13. MHA's/TMA's SHALL NOT BE PAINTED. 14. ANTENNAS SHALL BE PAINTED, WHEN REQUIRED, TO MATCH EXISTING ANTENNAS IN ACCORDANCE WITH ANTENNA MANUFACTURERS' SURFACE PREPARATION AND PAINTING REQUIREMENTS. ALLGON ANTENNAS SHALL USE ALLGON SYSTEM AS; ALLGON DOCUMENT NUMBER 990323/LL KATHRON TECHNICAL BULLETIN #119 OCT. 99. 15. CABLE SHIELDS, AND TOWER CONDUITS SHALL BE GROUNDED AT THE TOP OF THE TOWER, WITHIN 10 FEET OF THEIR CONNECTORS, AND AT THE BOTTOM OF THE TOWER ABOUT 6 INCHES BEFORE THEY TURN TOWARD THE FACILITY. THEY SHALL BE GROUNDED AT THE MIDPOINT OF TOWERS THAT ARE BETWEEN ISO FEET AND 300 FEET HIGH, AND AT INTERVALS OF ISO FEET OR LESS ON TOWERS THAT ARE HIGHER THAN 300 FEET. THEY SHALL BE ALSO GROUNDED AT THE WAVEGUIDE ENTRANCE TO THE FACILITY. 16. APPROVED GROUNDING KITS, WHICH INCLUDE GROUNDING STRAPS, SHALL BE USED TO GROUND THE COAXIAL CABLE SHIELDS, AND CONDUITS. THE GROUND CONDUCTORS FOR THE KITS AT THE TOP OF THE TOWER, AND IN THE MIDDLE SECTION OF THE TOWER, ARE BONDED DIRECTLY TO TOWER STEEL USING EXOTHERMIC, BOLTED, OR APPROVED CLAMP CONNECTIONS. 17. ALL RADIO SIGNAL. CABLE SHALL BE LABELED WITH COLOR -CODED ELECTRICAL TAPE (3M SCOTCH 35. 7 MILS THICK, 1/ INCH WIDE, VINYL ELECTRICAL TAPE, OR CONTRACTOR APPROVED EQUAL) AND BRASS OR STAINLESS STEEL IDENTIFICATION TAGS AS SPECIFIED IN DETAIL NUMBER 600, 600A. 18. THE SUBCONTRACTOR SHALL FILL IN DETAIL 601 AND AFFIX IT TO A WEATHER -PROTECTED LOCATION (E.G., THE SHELTER INTERIOR WALL) NEAR THE CABLE PORT. 19, RECOMMENDED SURGE ARRESTORS THAT CAN BE USED WITH THE BTS EQUIPMENT: ANDREW: 7-16 DIN M/F WIDEBAND 1/4 WAVE, GAS TUBE WITH DC BYPASS HUGER+SUHNER: 7-16 DIN M/F WIDERAND 1/4 WAVE, GAS TUBE WITH DC 13YPASS 20, DUPLEXERS AND/OR DIPLEXERS AND MOUNTING HARDWARE (J CLAMPS) WHERE REQUIRED SHALL BE SUPPLIED BY CONTRACTOR AND INSTALLED BY THE SUBCONTRACTOR. 21. MHA/TMA'S TO BE INSTALLED AT TOWER TOP, SHALL BE SUPPLIED BY CONTRACTOR (WHERE REQUIRED) AND INSTALLED 13Y THE SUBCONTRACTOR. 22. ANTENNA FEED LINE SYSTEM SWEEP TESTING SHALL BE PERFORMED AND REPORTED IN ACCORDANCE WITH THE REQUIREMENTS OF AWS DOCUMENT NO. WNS-0284 (LATEST REVISION). CONTRACTOR WILL NOT ACCEPT A RADIO SIGNAL CABLE INSTALLATION WITH UNSATISFACTORY SWEEP TEST RESULTS, DETAIL L" 520_ BECHTEL TELECOMMUNICATIONS 12131 1 WA H AVENUE 8NE 0 KIRKLAND, WASHLNGTON 98034 6 RF BILL OF MATERIALS ALPHA SECTOR BETA SECTOR GAMMA SECTOR I SYS. AZIMUTH 30t7 TN ITEM TOTAL SUPPLIED NO ITEM DESCRIPTION OUANTITY BY (SEE NOTE 1) UMTS TX/RX1 RX2 ANTENNA (i) EXfST1NG UTMS GENERIC 1900 SBDP 1 WITH BRACKETS MECHANICAL. DOWNTILT 0' --- --- 2 TOWER MOUNTED AMPLIFIER UMTS 1 1 (2) CONTRACTOR --- c 3 — o MAIN COAX 1 5/8 15OFT, 15OFT. CR 50 1873(300 FT.) CONTRACTOR w c a 4 AT&T WIRELESS SITE NAME: RENTON HILLS., AT&T_ SITE #: STTLWASGI7 w RF NOTES AND BiL.L OF MATERIALS 0 10/0�/as ISsM FOR NORTEL UMTS IBIS 12603 82ND AVE. SOUTH A 10/02 03 ISSUED MR REVIEW NF1 w RENTON, WA 98055 r+0_ DATE REASMS e1 arx as omv mAd" Inv AT&T WIRELESS SERVICES, INC. AS SHOWN D m 1wt DRIA ar: WEJ 24897-612-H I STTLWASGI7-A04 A SCANN_o OCT 0 8 -� C FFA A