Loading...
HomeMy WebLinkAboutTED4003195.1SEC. 15, TWP. 23 N., RGE. 5 E., W.M. 0 U a 0 0 0 a_ LU w X X Ln M U N Ln 0 N O if m c w i N Ln wo � N �o o � Y Z N 0 0 r L jhr = J Z. U N 0 2 g�g 26 a Ln Z 0 I W �i = W it in in Q w a 0 In z 0 w ry One - 03 Bar Two - 03 Bar hoop 03 Bar each corner 03 Bar each side lop on(! bottom One - "3 Dui across bottom S� 1 - 03 Bar hoof 2 - "3 Bar hoop 03 Bar each corner #3 Bar each side #3 Bar each way A NOTES Frame and grate 1. If wire mesh is used as an alternate to rebur, it shall (See Stondard Plan not be placed in the knockouts. for details) 2. The bottom of the precast base section shop be minimum 4" thick and may be rounded. 3. Knockouts may be either round or "D" shape. Ploe to be installed in factory supplied knockouts. Hole size shall be equal to pipe outer diameter plus concrete inlet wall thickness, 18" MAX. 6" Riser Section 4. The taper on the sides of the precast base section and riser section shall not exceed 4%. 5. Frame and grate may be installed with flange down or cast into riser. 12" Riser Section 12" Precast Base Section {Measurement at the top of the base) 'ICI Ln N 1-3-95 Revised Precast bose section and notes FP 10-11-93 Revised notes and resigned. SJD - DATE REti'IS[ON [1'/ AFFR'D CONCRETE INLET euwtraspe tTent M►irnt�T Of Ttwwre�t�rtgr ae�na, sttatw�ra Y ADOPTED O CITY OF RENTON + n Standard Plans Last Date 1/03/1995 B01 O PIan Na B -26 SP PAGE NOTES: Frame and grate (see Standard Plan 1. If wire mesh is used as an alternate to rebur, it shall for details) not be placed in knockouts. 2. The bottom of the precast base section shall be minimum 4" thick and may be rounded. 3. Knockouts may be on all four sides, either round or "D" shape. Pipe to be installed in factory supplied knockouts. Hole size shall be equal to pipe outer 6" Riser Section diameter plus catch basin wall thickness, 20" MAX. A. The maximum depth from the finished grade to the pipe invert is 5 -0" . 5. The taper on the sides of the precast base section and riser section shall not exceed 4%. 6. Frame and grate may be installed with flange down or cast into riser. 12" Riser Section rN 22-- Precast Base Section �jj I (Measurement at the top 3'j ( \ `• MIN of the base) 5-2G-95 Revised precast base section and notes. FP 5-7-93 Revised notes and resigned. DATE _ REv15II'}N M lil API=Ft'D CATCH BASIN TYPE I k161111101Q1 ST/re a►NtMt1 Q T111RL'a7�Tt� d„►u. wrlrsre. Y O ADOPTED CITY OF RENTON + A Standard Plans r Last Date 5/26/1995 SP PAGE B012 'flan No B -01 6„ SLOPE 0.05 F T /FT STREET SECTION 0 NOTES: -'�--, 1. 3° TO 5° DRAFT PERMITTED AS NEEDED. 2. WELDING NOT PERMITTED. 3. DIMENSIONS SHALL HAVE ±1 /16" TOLERANCE EXCEPT AS NOTED, WIDENED CURB 4. FOUNDRY NAME SHALL BE EMBOSSED ON TOP OF GRATE. LETTERING TO BE RECESSED 1 /16". I- - 5. SEATING OF GRATE SHALL BE ACCOMPLISHED BY ONE OF' THE FOLLOWING: ALTERNATE A SHALL BE 8 PADS, 1 1/2% 3/4"x 1/81, B INTEGRALLY CAST WITH THE GRATE. co ALTERNATE B SHALL BE A MACHINED SURFACE OUTSIDE A 17" CIRCLE, BOTTOM ONLY (SEE SECTION B-B). 6. MATERIALS IN ACCORD WITH DIVISION 9 OF STANDARD SPECIFICATIONS SECTION "METAL FRAME AND GRATE FOR CATCH BASIN OR INLETS". �- FACE OF CURB 7. MATERIAL USED FOR GRATE SHALL BE DESIGNATED BY EMBOSSING DI (DUCT IRON) OR CFS (CAST STEEL) NEAR MFR'S NAME. — -- 7. SEE DWG. NAME BR-32 FOR FRAME AND GRATE DETAIL GRATE IS OLYMPIC FOUNDRY #SM50G, #SM50GL, ,f #SM50SL, OR EQUAL. FRAME IS OLYMPIC FOUNDRY #SM50 OR FOHAI SECTION 13---13 SECTION A --A DATE REVISION BY JAPPRt CONSTRUCTION JOINTS i- NORVAL GUTTER GRADE R-31950E SURFACE WATER UTILITY OPEN CURB FACE FRAME & GRATE INSTALLATION DETAIL C ADOPTED CITYOF RENTON • STANDARD PLANS LST DATE: 2/96 DWG. NAME: BR-30 SP PAGE: BO1 7 a NOTES. ® �p Frame and grate (see Standard Plan 1. If wire mesh is used as an alternate to rebur, it a for detail) shall not be placed in the knockouts. 2. The bottom of the precast base section shall be a minimum S oI 4" thick and may be rounded. �7 A 34 Knockouts may be on all tour sides. Pipe to be 30" installed in -factory supplied knockouts. Hole size shall 2A 201- be equal to pipe outer diameter plus catch basin wall thickness, 26"" maxi mum° Rise, --Section 9. The taper on the sides of the precast base section and riser section shall not exceed 4% One 43 Bar hoop for 6:'\ , i I6" or 12 5. Frame and grate may be installed with flange down or i wa 3 Bar hoop for 12 cast into riser. Reducing Section Two #3 Bar Precast Base Section CMeasurement at the top of the base � MIN 4'3 Bar each corner #3 Bar each side #3 Bar each way 6-23-95 Revised precast base section and notes. A3N ---- 5-7-93 Revised notes and resigned. SJD - OATE REVISION BY APPR'D CATCH BASIN TYPE 1L WASHINGTON STATE DEPARTMENT OF TRANSPORTATION OLYNPIA, WASHINGTON Y Q ADOPTED CITY * OF RENTON + Standard Plans WA Last Date 5/26/1995 BQ Vlan Na n _011 A SP PAGE 14 oF .... TFL pE WA 33251 0�'•ASTER.• �SS/ONAL EN�� 1 ') — n A— n A —� RECOMMENDED FOR APPROVAL 8) ,A. yDATE.- �. BY.. DA /T- BY DA TE.- 1477 1 NE 29th Place Suite 70 7 Bellevue, Washington 98007 425.885.7877 Fax 425.885.7963 DESIGN ENC31NEERING • PLANNING • SURVEYING STORM DRA/NA GE DETAILS CORL- ✓061020522 SCANNEo APR 2 2 C4.35