STORM DRAINAGE NOTES
Y
9 o
W
Z
1. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY OF RENTON PRIOR TO THE CONSTRUCTION MEETING
w 2
1
N
2. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERL Y PREPARED FOUNDA LION IN ACCORDANCE WITH 915D0T
7-02..3(1). THIS SHALL INCLUDE LEVELING AND COMPAC77NC THE TRENCH BOTTOM, THE TOP OF THE FOUNDATION MATERIAL,
AND ANY REQU/RED PIPE BEDDING TO A UNIFORM GRADE SO THAT THE ENTLRE PIPE /S SUPPORTED BY A UN/FORML Y DENSE
UNYIELDING BASE.
3. STEEL PIPE SHALL BE GAL VAN/ZED AND HA VE ASPHAL T TREA TMENT /I OR BETTER INSIDE AND OUTS/DE.
►�
4. ALL DRAINAGE - STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL .HAI/E SOLID LOCKING LIDS. ALL DRAINAGE
- -
STRUCTURES ASSOCIATED W171 A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE LOCKING LIDS.
[T�
5. ALL CATCH BASINS SHALL CONFORM TO THE CITY OF RENTON STANDARDS
6. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A
MINIMUM 3.1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. CUL I/ERT S SHALL HAVE BEVELED END
SEC77ONS TO MATCH THE S/OE SLOPE.
D MU ND 7, ROCK FOR ERGS/ON PROTECTION OF ROADWA Y DITCHES WHERE REQUlRE ST BE OF SOU QUARRY ROCK PLACED TO
O
A DEPTH OF 1 FOOT AND MUST MEET THE FOLLOWNG SPECIFICATIONS.• 4" 8%407,70%' PASSING; 2" 4' 1?0CK/30Z-40X
PASSING- AND -2" ROCK/10%20X PASSINGG, INSTALLATION SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND
L'
SPECIFICA 77ONS.
�I
8. NOT APPLICABLE.
9. BEFORE ANY CONSTRUC7ON OR DEVELOPMENT AC77WTY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WTH THE
Wq
CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
0
10. ALL CONS TRUC7ON SHALL BE IN ACCORDANCE WITH 171E "1996 STANDARD SPECIFICA ]TONS FOR ROAD, BRIDGE AND
MUNICIPAL CONS7RUC770N0 PREPARED BY WSDOT, AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY
THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS.
11. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS WHICH ARE ON FILE /N THE
DEPARTMENT OF PUBLIC WORKS ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY
OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM W47FR U77LITY.
12 A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION /S IN PROGRESS.
73 DA 7UM SHALL BE U. S. G. S. UNLESS OTHERWSE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS.
REFERENCE BENCHMARK AND ELEVA77ON ARE N07ED ON THE PLANS.
O
14. ALL SEDIMENTA770N/EROS/ON FACIL177ES MUST BE IN OPERA77ON PRIOR TO CLEARING AND BUILDING CONSTRUC770N, AND
THEY MUST BE SA 77SFACTORIL Y MAINTAINED UN77L CONSTRUC7ON /S COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION
W
HAS PASSED.
75. ALL RETEN770NIDEIEN77ON FACIL177ES MUST BE INSTALLED AND IN OPERA77ON PR/OR TO OR IN CONJUNC77ON WTH ALL
CONS TRUC7ON AC77WTY UNLESS 01HERWSE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM W,47FR U77LITY.
16. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED
STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT ANO APPROVED BY THE DEPARTMENT OF PUBLIC WORKS,
STORM WATER UTILITY.
17. STRUCTURES SHALL NOT BE PERMITTED Wl11IN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET
FROM THE TOP OF ANY CHANNEL BANK
18. ALL CATCH BASIN GRA TES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.
m�
19. OPEN CUT ROAD CROSSINGS THROUGH EX/STING PUBLIC RIGHT-OF-WAY WLL NOT BE ALLOWED UNLESS SPECIFICALLY
i > APPROVED BY THECITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER ENGINEE
0 20. ALL BUILDING DOWNSPOUTS AND F0077NG DRAINS SHALL BE CONNECTED TO TTlE STORM DRAINAGE SYSTEM, UNLESS
N APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM W47FR UTILITY. AN ACCURATEL Y
DIMENSIONED CER77FIED AS-BUIL T DRAWING OF THIS DRAINAGE SYSTEM N9LE BE SUBMITTED TO THE CITY OF RENTON UPON
COMPLE170N.
> 21. ISSUANCE OF THE BUILDING OR CONSTRUC7ON PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE
� W CONTINUING LEGAL 09L16A77ON AND/OR LIABILITY CONNEC7ED WTH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY
tr
OF RENTON DOES NOT ACCEPT ANY OBLIGA77ON FOR THE PROPER FUNC770NING AND MAINTENANCE OF THE SYSTEM PROVIDED
o 2 _ DURING CONSTRUCTION.
22. THE CONTRACTOR SHALL BE RESPONS/8LE FOR PROWD/NG ADEQUATE SAFEGUARD, SAFETY DEVICES, PROlTC77VE
N EQUIPMENT, FLAGGERS, AND ANY 0771ER NEEDED AC77ONS TO PROTECT THE LIFE, HEAL lTl, AND SAFETY OF THE PUBLIC, AND TO
PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED IN THE CONTRACT ANY WORK WITHIN THE
Q !RAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN
BY THE TRAFFIC ENGINEERING D/W510N OF THE DEPARTMENT OF PUBLIC WORKS. ALL SEC77ONS OF THE W 00T STANDARD
SPECIF/CA 77ONS 1-07-23,, TRAFFIC CONTROL, SHALL APPLY
23. SPECIAL DRAINAGE MEASURES WILL BE REOUIRED IF THE PROJECT LOC47701V IS WITHIN THE AOUIFER PR07FC77ON AREA.
3 24. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER REZATED PERMITS
N o PRIOR TO ANY CONSTRUC7ON AC77WTY.
25. ALL LOCA7701VS OF L-XI517NG U17LI77ES SHOWN HEREON HA VE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM
Q A VAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROX/MA TE ONL Y AND NOT NECESSARY( Y COMPLETE. IT lS
THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTZY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN
AND TO FURTHER DISCOVER AND A VOID ANY OTHER U7LII7ES NOT SHOWN HEREON HATCH MA Y BE AFFECTED BY THE
L.LjIMPLEMENTA 17ON OF THIS PLAN. 77 E CONTRACTOR SHALL CONTACT THE UNDERGROUND UTIL177ES LOCATION SERVICE
N o (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUC770N. THE OWNER OR HIS REPRESENTATIVE AND THE ENGINEER
SHALL BE CONTACTED IMMEDIATEL Y IF A CONFLICT EXISTS.
m 26. ALL STORM DRAINAGE STRUC7URES, AS DESIGNATED IN THE PLANS, SHALL BE ONE OF THE FOLLOWING.•
A. YARD DRAIN - CITY OF RENTON SID. PLAN NO.. B011, ASSOCIATED SAND AND GRA VEL CB-10, OR EQUAL.
B. INLET - CITY OF RENTON STD. PLAN NO. 9010, ASSOC/A 7ED SAND AND GRAVEL 0-17, OR EQUAL.
C TYPE 1 CA TCH BASIN - CITY OF RENTON STD. PLAN NO 9012, ASSOC/A TED SAND AND GRA VEL CB-15,, OR EQUAL.
D. TYPE ll CATCH BASIN - CITY OF RENTON STD. PLAN 9027, (WlTI1 MIN/MUM 24" DEEP SUMP BELOW PIPE INVERT),
ASSOCIATED SAND AND GRA VEL PRECAST CA TCH BASIN, OR EQUAL.
E. BAFFLE- TYPE OIL/WA TER SEPARA TOR VAUL T - CITY OF RENTON 57D. DRWG. NO .3 4. 5 (DEPENDING ON DEPTH AND
DETAILS
IN THESE PLANS), OR EQUAL.
F. SPEC/AL CATCH BASINS OR DRAINAGE STRUCTURES SHALL BE AS DETAILED /N THESE PLANS. N07F• ALL UNIT
COVERS SHALL BE PER APWA STANDARDS AND ALL STRUCTURES DEEPER THAN FIVE FEET (R/M TO INVERT) SHALL BE
TYPE
zo lI AND EQUIPPED WTH MANHOLE STEPS OR A MANHOLE LADDER, PER APWA STANDARDS.
V)
w 27. ALL FRAMES, GRA-5 AND/OR SOLID COVERS SHALL BE CAST IRON OR DUCTILE IRON AND SHALL MEET CITY OF RENTON
STANDARDS.
0 0
A. STANDARD FRAME AND GRATE - C1TY OF RENTON STD. PLAN NO 90204, OL YMPIC FOUNDRY CO. NO 5M60, OR
EQUAL.
.13
B. SELF-LOCKING VANED GRAZE - CITY OF RENTON STD. PLAN 8019 OR EQUAL.
W C. 1HRU-CURB INLET FRAME AND GRATE - CITY OF RENTON STD. PLAN NO. 9017 OL YMPIC FOUNDRY CO. NO.. 5IV52 OR
o EQUAL.
D. SOLID, LOCKING, RECTANGULAR COVER - CITY OF RENTON STD. PLAN NO 8020, OL YMPIC FOUNDRY CO. NO SM505
OR EQUAL.
m W E. SOLID, LOCK/NG, ROUND COVER - CITY OF RENTON STD. DRWG. NO.. 36 7, OL YMPIC FOUNDRY CO. NO. YH36D/T OR
EQUAL. NOTE ALL SOLID C01/ERS SHALL BE MARKED "DRA/N. " ALL GRATES SHALL BE MARKED "OUTFACE TO SIRE U
- DUMP NO POLLUTANTS. " ALL GRATES SHALL BE DEPRESSED 0.10 FEET FROM SURROUNDING CURB OR PAVEMENT TO
INSURE ADEQUA If DRA/NAGE
z TAD-�tO-.fly!`
28. ALL STORM DRAIN PIPE MAY BE CONSTRUCTED OF ONE OF THE FOLLOWING MATERIALS UNLESS OTHERWISE SPECIFIED IN
THE PLANS. ALL PIPE JOINTS MUST BE GASKEIfD WATERTIGHT AND MUST BE OF THE SAME MATERIAL AS THE PIPE. ALL PIPE
_
SHALL HA VE A MINIMUM COVER OF 12" AND SHALL BE ADEQUA TEL Y PROTECTED DURING CONSTRUCTION (REFER TO THE
MANUFACTURERS RECOMMENDATIONS FOR MINIMUM COVER FOR HEAVY EQUIPMENT LOADINGS)
A. DUCTILE IRON 4" THROUGH 14" DIAMETER PIPE SHALL BE CLASS 52 AND 16" THROUGH 24" DIAMETER PIPE
SHALL BE CLASS 50, ALL IN ACCORDANCE WITH USA STANDARD A-21.1 (AWWA C-51) ALL JOINTS SHALL
BE PUSH -ON, MECHANICAL, OR FLANGED.
B. CONCRETE 4" THROUGH 18" DIAMETER PIPE SHALL BE NON -REINFORCED, BELL AND SPIGOT WITH RUBBER
i
GASKET JOINTS, CONFORMING TO A57M C-14 (CLASS 1). 21" THROUGH 36" DIAMETER PIPE SHALL BE
PROVIDE 12'
REINFORCED, BELL AND SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C-76.
SEPARATE(
C. PVC 4" THROUGH 18" DIAMETER PIPE WITH 18" TO 36" OF COVER SHALL BE IN ACCORDANCE WITH ASTM
D3034 SOR 21. 4" THROUGH 18" DIAMETER PIPE, WITH COVER 36" OF COVER SHALL BE 1N ACCORDANCE
WITH ASTM 0034 SDR 35. ALL JOINTS SHALL BE PUSH -ON WITH RUBBER GASKETS (NOTE PVC PIPE
USED FOR DOWNSPOUT LEADERS, YARD DRAINS, AND LANDSCAPING DRAINAGE MAY BE A57M D2729 WTH
SOL VENT WELDED JOINTS, 12" MINIMUM COVER.)
D. CORRUGATED HIGH DENSITY POL YETHYLENE PIPE (CPEP) 8" THROUGH 36" DIAME7FR SHALL BE IN
ACCORDANCE WITH AASHTO M-294, AS SUPPLIED BY ADVANCED DRAINAGE SYSTEMS DESIGNATED N-12, OR
EQUAL.
29 ALL BUILDING ROOF DRAIN DOWNSPOUTS AND FOOTING DRAINS SHALL BE DIRECTLY CONNECTED TO THE MAIN STORM
DRAINAGE CONVEYANCE SYSTEM. ROOF DRAINS AND F0077NG DRAINS SHALL BE SEPARATE SYSTEMS AND SHALL BE
CONSTRUCTED OF 4" (OR 6" DIA. WHERE SHOWN) RIGID PVC PIPE (NON-PERFORA TED FOR ROOF DRAINS, PERFORATED FOR
F0077NG DRAINS) SUFFICIENT CLEANOUTS AND BENDS SHALL BE INSTALLED SO THAT THE SYSTEM CAN BE EASILY MAINTAINED.
THE SYSTEM SHOWN HEREON /S SCHEMA TIC ONL Y. THE DRAINAGE/GRADING CONTRACTOR OR LANDSCAPER MA Y AL TER THE
LAYOUT AS REQUIRED TO BETTER DRAIN THE SITE, W11 PRIOR APPROVAL OF THE ENGINEER. ALL ROOF AND FOOTING DRAINS
SHALL BE ADJU57FD AS NECESSARY TO A VOID IMPAC77NG THE EXISTING TREES DEN07FD "TO BE SA VED" ON THE GRADING
PLAN. DRAIN LINES SHOULD BE LOCATED OUTSIDE THE DR/PLINE OF TREES WHEREVER POSSIBLE. THE CONTRACTOR SHALL KEEP
A DIMENSIONED RECORD OF THE IOCA77ON OF ALL PIPES AND CLEANOUTS ANO SUBMIT SAME TO THE ENGINEER AND OWNER
STD. MANHOLE -�
ACCESS LID
UPON COMPLE77ON OF THE WORK.
r.
RIM -379 06 . •.
3Q CON57PUC77ON OF DEW,4 TER/NG (GROUNDWA TER INTERCEPTION) SYSTEMS SHALL BE IN ACCORDANCE WITH THE APWA
RISER BRICKS
STANDARD SPECIFIC47ONS, SEC77ON 61-302.
(TYP.)
I_n
31. ANY OPEN CUTS OF EXIS77NG PUBLIC ROADWAYS SHALL BE BACKFILLED AND COMPACTED IN ACCORDANCE WITH CITY OF
RENTON STANDARDS. ALL CUTS INTO EX/S77NG ASPHALT SHALL BE ALONG NEAT, CON77N000S, SAVED LINES. A IFMPORARY
COLD MIX PATCH MUST BE PLACED IMMED/ATEL Y AFTER BACKFILL AND COMPAC77ON. THE EXISTING SURFACING MUST BE LIFT ROD
REPLACED /N KIND (OR 4 INCHES OF COMPACTED CLASS "B" ASPHAL T CONCRE7� WHICHEVER lS GREA TER) WITHIN 14 DA YS OF F HANDLE a
COLD PA TCH/NG HE CONTRACTOR SHALL CLOSEL Y FOLLOW REQUIREMENTS OF THE RIGHT -OF -WA Y PERMIT SPECIFICALL Y,
ALLOWABLE WORKING HOURS, DETOUR AND WARNING SIGNS AND NO77FICA 77ON OF ROAD AL TERA 77ONS TO 171E POLICE AND/OR
OTHER EMERGENCY SERVICES.
PROVIDE MAINTENANCE
ACCESS BY WELDING (4)
CROSS BARS TO (3)
VERTICAL BARS AS SHON9V.
HINGE UPPER BARS W/
FLANGES/BOL TS & PROVIDE
LOCKING MECHANISM
(W/PADLOCK) ON LOWER
END. COCA IF LADDER STEPS }
DIRECTZ Y BEZ 0W j
1 F�R�MNCB 2
32'
GAL V.
LADDER
STEPS
WELD BARS AT ALL
JOINTS (TYP.) GAL[
ENTIRE STRUCTURE
AFTER ASSEMBL Y.
0 VERFL OW EL. 377 0
3/4" BAR
PLAN
SECTION
HOOK CLAMPS (4) PLACES.
EVENL Y SPACED. SEE DETAIL.
16-3/4 "0 GAL V.
BARS E"QOALL Y
SPACED.
L 18N
CB RISER
VERTICAL
BARS
HOOK CLAMP 1
ANCHORED TO CB
RISER
TOOK CLAMP DETAIL
AIR VENT EL. 380.0
WITH BEE HIVE
STRAINER
a
Ga
PLAN
24 " CUP RISER
FROP- T SHEAR
GATE SEE DETAIL e
THIS SHEET a
36¢n
18" lE :365.00• as
yl/],ill/IA/�i
NON-METALIC
LADDER
STEPS (TYP.)
PIPE SUPPORT- 3 "x 0.090 GA.
STEEL STRAPS BOL TED OR
IMBEDDED 2" IN WALL A T
MAX. 3' SPACING (TYP.)
3"0 GAL VANIZED
/P/-)Ai A /P VENT PIPE
2" IN WALL AT
SPACING (TYP.)
DIAM. MIN.
C 7 2A EMERGENCYOVERFLOW DETAIL
SCALE' 1/21#=1'-0"
4
210 GAL VANIZED
IRON AIR VENT PIPE
N
ea BOT EL' 361.06
a
a e d
a a a
0.5' MIN
1E i373 76
37� 31
REMOVABLE WATERTIGHT
COUPLING (OPTIONAL)
6" CUP
RE0 D £LEV.
6" MIN.
WELDED ELBOW
MACHINE CUT OR DRILL
ORIFICE IN END PLATE
4
6" MAX.
ELBOW DETAIL
NO SCALE
4
� � I
F-1/2y-PIPE
DIAM. MIN.
a
a
a a
d e 4
a a
AIR VENT PIPE INLET WITH
BEE HIVE S7RAINER
PRIMARY EMERGENCY OVERFLOW
JAILHOUSE INLET EL. -*76. 65• 376.
OVERFLOW EL. -976. 35
PIPE SUPPORT 3"x 0.090 GA.
STEEL STRAPS BOL TEED OR
IMBEDDED 2" IN WALL AT
MAX. 3' SPACING (TYP.)
6" ELBOW WITH 6-010 ORIFICE
SEE ELBOW DETAIL, THIS SHEET
2N2 "0 GAL V. IRON 45' BENDS
24 X24 X18 x8" CMP CROSS
18" !E :365 00 36}, 90
NON-POUROUS,, NON -
SHRINKING GROUT AROUND
PIPE AS REQ D (TYP.)
8 GAUGE ALUMINUM STRAPS
THIN STAINLESS 57FEL
ANCHOR BOLTS (TYP.)
1' SEC77ON OF PIPE ATTACHED
BY GASKETED BAND TO
ALLOW REMOVAL.
DRILL OR MACHINE
CUT 3-1/16 "0 ORIFICE
IN RESTRICTOR END
PLA IF EL. 363.00
6010 MANHOLE
CB 2 CONTROL STRUCTURE DETAIL
SCALE' 1 "=2
ADJUSTABLE -
HOOK
NOTES.'
1. SHEAR GA IF SHALL BE
A. SHEAR GA 7F CAST IRON BOO Y AND GA 7F OL YMPIC FOUNDRY STANDARD OR EQUAL OR
B. SHEAR GA TE, ALUMINUM OR CAST IRON, DRAINAGE SPECIAL 77ES (SA VANNAH, GA.) STD. OR EQUAL.
2. GATE SHALL BE 8" DIA. UNLESS OTHERWISE SPECIFIED.
3 GATT SHALL BE JOINED TO TEE SEC770N 8Y9OLTIN G (THROUGH FLANGE), WELDING,
OR OTHER SECURE MEANS.
4. LIFT ROD: AS SPECIFIED BY MANUFACTURER WTH HANDLE E17FNDING TO WITHIN ONE FOOT OF
COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD.
GA ATE DETAIL FROP-T SHEAR
NO SCALE
FINISHED GRADE
8 "x U "X 1/4 "
STEEL PLATE
45 BEND
Wl TH Pt UG
PL UG
DIAMETER AS
NOTED ON THE PLANS,
STORM CLEANOUT DETAIL
pFH. SAFE
.� yc
p 33251 `
OA*-. / TEENG� 4.
AL
RECOMMENDED
FOR APPROVAL
BY. DA TT•
BY DA TE.-
BY DA 1F
7477 1 NE 29th Pace Suite 101
Bellevue, Washington 98007
'COW 425.885.7877 Fax 425.885.7963
�zw�
DESIGN
ENGINEERING • PLANNING • SURVEYING
ROAD & STORM DETAILS
CORE 109102052
C4.31
SCANNED APR 2 2