Loading...
HomeMy WebLinkAboutTRO4103195.4z z s U C N 0 z 0 It 1 ZJY rn a a a 0 <C I_- LLJ = Z ry Q ::D Z J o a,, a� o 0 � O �E Q �4 U _ UJ �W -0 Q �a E FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL -- TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LUG CLEAR EPDXY SPLICE KITS ON ALL THRU 2" MIN, GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE - PAD -� 51t )r 1-#8 GREEN 2-(SIZED AS REQ'D) LIGHTING SYSTEM WIRES TO CONTACTOR 5/8"x8' COPPER -CLAD GROUND ROD - ll�Fill,Flll Flli'ill GROUND CLAMP 4> -PVC CONDUIT SYSTEM CONCRETE O FOUNDATI ON- I--- DR DI --�I IA. TO LUMINAIRE 1 /4" MINIMUM /-DRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. fill=Flil- ►1� IIII� Fill TYPICAL LIGHTING UNDERGROUND SYSTEM nnut CITY®PTED OF RENTON Standard plans 1, 5 . LST DATE:12/96 DWG. NAME: JR-06 METER TO BASE PHOTO DELL = J LJLj U Z C Q3 `�o° R MAIN 15A in TEST SWITCH 50A 20A m SIGNAL W Q o o LIGHTING A w z z w Y u o re � w � = a O A U IL LIGHTING B a- a- d- LIGHTING C LL1 Q 0 z 0 0 20A 20A I 1 1 I::I LIGHTING D SP PAGE: J007 j pA yi1�l! WYE SPLICE SPLICE KIT /,�-'�//////////loll ....�������1\\1�=�\\\� • FUSE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON Standard plans �F NUO`er LST DATE: 11 /5/96 DWG. NAME: JR-12 SP PAGE: J013 All dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 400OPSI concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1 /2" 10 gage divider plate complete with fasteners. Non -concrete Boxes may be submitted for approval. Evaluation will include an H-20 Load Test. JUNCTION BOX DIMENSION TABLE � c - IV ARK ITEM BOX TYPE TYPE 1 TYPE 2 ALTERNATE A ALTERNATE B A Box Outside length 22" 22" 33" B Box Outside Width 17" 17" 22 1 2" Box Inside Length 18" 19" 28" D Box Inside Width 13" 14" 17" IC E Lid Length 18" 18" 26 1 2" F Lid Width _ 13" 13" '17" G Box Depth 12" 12" 12" H Lid & Frame Depth 5 16" 5 16" 5 /16" J Wall Thickness Min. 1 1 2" 1 1 2" 1 1 2" K Wire Reinforcement W-3 W-2.5 W-2.5 L Le end See Detail See Detail See Detail ITEM MATERIALS Box _ 6000 PSI concrete See Notes Frame Diamond Plate Steel - A786 L'Id Su )port 1/8"loin. Thick Steel C, L or T. - A36 Lid Diamond Plate Steel - A78Ei Anchors Steel Wire or Tee Plate Reinforcement ASTM A-82 Steel *GALVANIZED STEEL LEGEND DETAIL (Mark L) SIGNALS T � l LIGHTING TS-LT TELEMETRY TRAFFIC SIGNAL SYSTEM LEGEND -Form Letters with 1 f8" Weld Bead. Grind off Diamond Pattern before forming letters. BREAKER SCHEDULE SERVICE VOLTAGE: 120-240 MOUNTING: BUS RATING: 250 AMP BUS CONNECTION: 2 P 3 W LOCATION DRAWING # CIRCUIT DESCRIPTION VOLTAMPS BREAKER ICKT, NO. CONNECTION A B CKT. N0, BREAKER VOLTAMPS A B CURCUIT DESCRIPTION A B AMP POLE AMP POLE LIGHTING A 1920 20 2 1 2 15 1 1440 LIGHTING CONTROL 1920 20 2 3 LIGHTING B t920 20 2 5 6 20 1 1920 RECEPTICAL 1920 20 2 7 8 20 2 1920 LIGHTING D LIGHTING C 1920 20 2 9 10 20 2 1920 1920 20 2 11 12 TOTAL 1 5760 5760 5280 1920 BUS A BUS B TOTAL LOAD COMMENTS 11040 7680 18720 VA VA VA MAIN BREAKER: 100 AMP LOCATION TOP FEED FEEDER SIZE: SOURCE: LINE AMPS: 100 AMP PHASING SINGLE KVA DEMAND: 20A 20A NOTES: 49. 225 AMP COPPER BUSSING 18 PLC PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) G 51. C.H. 2P 20 AMP BREAKER (BAB2020) F 52. C.H. 1 P 50 AMP BREAKER (BA81050) 1 53. C.H. 1 P 20 AMP BREAKER (BAB1020) C.H. 1 P 15 AMP BREAKER (BAB1015) a 0 0 0 0 0 6 0 0 1 54, 55. MILBANK METER ENCLOSURE (MS-24-TB) 56. HUBBELL SWITCH (CS1201-1) o ° o 51 50 ° 51 52 54 ° 51 53 ° 51 O 0 49 0 O O 10 00000000ooa0000 O ° 66 0 57 56 ° 0 58 0 O � 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898-1) 58.. SQUARE D LIGHTING CONTACTOR (981 ODPA32VO2U1) 61. SOUTHCO DOOR S.S. HINGE (F6-3-1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2-626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC REQUIREMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER MATERIAL: COATING TYPE: DRAWN BY: MEKKI AL-AZADI HARDWARE: QUANTITY: FINISH: COLOR: DATE: OCT 24, 20021 PAGE: OF: NOm. ILLUMINATION SYSTEM LEGEND w N PLAN VIEW � e � .x ELEVATION VIEW -�� BELL ENDS N. 2• k2' Ay.ON ON CDUIT TW. 6" GRAVEL PAD COMPACTED TYPICAL JUNCTION BOX INSTALLATION DETAILS La ® TYPE 'I' BOX ❑ TYPE 'II' BOX Ux7 x3/iB. 1'Lon9 HOOK DETAIL PLAN SYMBOLS (2 Hook. per Lid) JUNCTION BOX DETAILS G� O ADOPTED CITY OF RENTON Standard plans FN� LST DATE: 1 1 /89 DWG. NAME: JR-36 SP PAGE:: JO16 -10.50- C 8.00 1.00 0 TYP 6.0 4.75x1.25 TYP 4. 2.00 TYP 16.00 LIGHTING STANDARD 8c JUNCTION BOX 7' 0 oOv O o Ov O ov 4 D O q v O ® O D O v a® O d ®v oD v o vp n q A eq o n q A °° O O o "pD 0A PLAN VIEW 0 D D1-is =® 4a 3' 00 4 O D A A o �^ ® DD Jpo (3A ®A e D D® p C7 o D ad e Dv D ON STREET LIGHT POLE JUNCTION BOX SIDE VIEW INDIVIDUAL JUNCTION BOX Ov Oo O 0DoOC7 O A p v D 4" DEEP O®v4 NOTE: CLASS 'B' CONCRETE TO BE USED IN D e C) = be0 CONSTRUCTION OF PAD 4 0 O D 4 0 A D D o Dv D CONCRETE PAD DETAILS v v ADOPTED PLAN VIEW CITY OF RENTON ,p- Standard plans F N LST DATE: 10/30/96 DV [ADDO'ni DWG. NAME: JR-07 SP PAGE: J008 T 3t9504 NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1 P 50 AMP BREAKER (B.AB1050) 53. C.H. 1 P 20 AMP BREAKER (BAB1020) 54. C.H. 1 P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS-24-TED B) 56. HUBBELL SWITCH (CS1201-1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898-1) 58. SQUARE D LIGHTING CONTACTOR (981 QDPA32VO2UI) Q 61. SOUTHCO DOOR S.S. HINGE (F6-3-1) w 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2-626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1 "X.25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC RE(-, REMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER c •�OM� Ai JOB NAME: CITY OF RENT, DISTRIBUTION:' CONTRACTOR: DAM - PURCHASE ORS_ MATERIAL: .125 5052-H32 ,ALUM, STING TYPE Mr HARD1i _.QUANTITY: FINISH: ry COLOR: - DATE: SCANNED APR 2 2 . (:�'P; 7--