Loading...
HomeMy WebLinkAboutWTR2703196.1a r I IE=41 1.94� EX #9, OUTFALL IE=408.97 EX # 10, OUTFALL IE=409.14 S88'14, 37'E 1 ` 1 SSMH, DTL 1/8 S,TA 1 +0 , 2' RT ' N.G.P.E. 0 1 IEIM4172 09 8" N 4„ CAP (J), ON $ =417.14�6 S) 2 P M LO OFF 1/ i----_----- FF=424.0 00, LOT 5 / A) 72, 332 ± SQ. FT. \ � I 420 g' ��tNk 418 ,, A 416 4 4 / 0 408 o� 406 BLDG. 40 WA TER & SE WER PLAN RECOMMENDED FOR APPROVAL. BY: _ DATE: BY: DATE: BY: DATE BY: DATE: R Cramer Northwest Inco-- ENGINEERS, SURVEYORS & PLANNERS 945 N. CENTRAL, STE. #104, KENT, WA 98032 (253)852-4880 (local) or 1-(800)251-0189 (toll free) (253)852-4955 (fax) E-MAIL: cniOcromernw.com s-&Kr SECTION 4, T 23 N, R 5 E LOT 5 \ � � A) _ 72, 332 ± SQ. FT. 420 416 61 -A < 470 408 40 \> p�/i 6 v BLDG. 04 4 02 g0 i------__.- 400 398 \ �� I 396 �O� \ 394 \ �q, \\�v i 390- - 388 GL "� TL # 042305- \ \/ o 00 Cb �v pe 03 03 Q0 Q0 96 6) W O N P Iq�I TL # 042305-9032-07 TOTAL AREA 110,180f SQ. FT. 2.5± ACRES -vc) S. LINE, N. E. 114, S.E. 1 /4 N88009'50 *V 172. 387' -, \ �9� �'o \ 406 o Ro_ 40 \ TL # 2599850000 W-3/9�e0� BENCHMARK. FOUND CONCRETE MONUMENT WITH 1 1/2" BRASS DISK IN CASE AT INT. UNION AVE. N.E. & N.E. 12TH ST. (S.E COR. SEC. 4, T23N., R5E.) ELEVATION — 415.95 U.S. FEET. SITE BENCHMARK. - FOUND RAILROAD SPIKE IN UTILITY POLE ELEVATION — 431.67 U.S. FEET. TRENCH RESTORATION NOTE: ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. NOTE: FILL AND COMPACT ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCAVATION FOR WATERMAIN INSTALLATION. SURVETEc: NNW SCAM 1 „_30' VERTICAL w►w � MM�AL ►� I90.i 1"I DATUM CITY OF R EN TON `SKDENOM: LSK °NE'"�" Di K AT FULL$ME rwowxx 'CALE A00MMLY Planning/Building/Public Works Dept. NO. REVISION I BY DATE APPR I omym. _17al EE) OCT 2 8 2 5 UTILITY CONFLICT NOTE THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERhCAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE O 1-800-424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATION OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT CRAMER NORTHWEST INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. ®ALPAY SHORT PLAT a7-9-28-04 FOR JIM ®ALPAY ono naw WATER & SEWER PLAN S• 3� 9C.csy B