SANITARY SEWER NOTES & SPECIFICATIONS
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST
EDITION OF THE WSDT/APWA STANDARDS AND SPECIFICATIONS.
2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8: 30
A.M. TO 3: 30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY
THE DEPARTMENT OF PUBLIC WORKS AT 235-2620. ALL STREET CLOSURES,
PARTIAL, OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24
HOURS IN ADVANCE. THE POLICE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24
HOURS IN ADVANCE.
J. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS
FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE
CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND
CITY OF RENTON STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING U TILI TIES SHOWN ARE APPROXIMATE AND IT SHALL
BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT
LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE.
5. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOURS NOTICE SHALL BE REQUIRED
PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING
CONS TRUC TION. (INSPECTION WILL BE A CCOMPL I SHED BY A REPRESEN TA TI VE OF
THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILL ALL
CONSTRUCTION.
CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE
CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE
AND ANY RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT
DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND
SIGNED BY A LICENSED PROFESSIONAL ENGINEER OF LICENSED
PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS
WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 81 INCHES,
THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE
COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH. MA TERIALS HOT MIX PA TCH SHALL BE
PLACED WI THIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT
STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G. S.
14. ALL DISTURBED AREAS SHALL BE SEEDED MULCHED OR OTHERWISE STABILIZED TO
THE SA TI SFA C TION OF THE DEPARTMENT FOR THE PRE VEN TION OF ON- SI TE EROSION
AFTER THE COMPLETION OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF
WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF
THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE
WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING
SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEINER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED
ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50.
17. IN UN -IMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18
INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL
DIRECTIONS TO MATCH PAVING.
i
SIDE SEWER MAIN TO
PROPERTY LINE
BUILDING SEWER
z
® o Z FUTURE
5;6 " SE WER PIPE ' g 6. ° I BL D G SEWER
6 " SIDE OUTLET TEE ?; 2 "X4 " STUD — SERVICE MARKER
PAINT UPPER PORTION WHITE
W AND STENCIL ON SIDE WORD
° "SE WER " WITH 3 " HIGH
BLACK LETTERS.
6" SIDE SEWER & BUILDING SEWER
z ?i`O-ire-Anop PLAN
» AS —BUILT"
S—BUILT" NOTE
OTE , EXPIRES 6/22/05 I
"AS -BUILT" IS BASED ON A ACTUAL FIELD SURVEY
BY TOUMA ENGINEERS AND INFORMA 170N SUPPLIED
BY CONTRACTOR.
6" SIDE SEWER
1: J. 5 MIX NO TE.
CONCRETE 60• ALLOWABLE MAX SIDE SEWER SHALL HA VE A
BLOCKING FOR CAST OR MINIMUM 5' COVER A T PROPERTY
DUCTILE IRON PIPE. LINE OR 3-5' LOWER THAN THE
6"MIN 4 •MAX LOWEST HOUSE ELEVATION, WHICH-
25 • M/N E VER IS L 0 WER.
6 "MIN HORIZONTAL
6" SIDE OUTLET TEE
SEWER MAIN
CONC. BLOCKING ANGLE
OF TEE AT MAIN OVER 25 "
ELEVA TION
o �
5xA
• G
1 29' MIN SLOPE
TYPICAL SIDE SEWER
ELEVA TION
EXISTING SEWER MAIN
6 " SIDE SEWER
6 "TEST TEE
TO BE INSTALLED
A T CONNECTION
NO TE.
MAKE TAP THROUGH CAST IRON
SADDLE SECURED TO SEWER MAIN
WITH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE
SEWERS TO EXISTING MAIN.
VITRIFIED CLAY, PLAIN &
REINFORCED CONCRETE, DI &
Cl PIPE SEWER MAINS ARE TO
BE CORE DRILLED.
SIDE SEWER SERVICE DETAIL
T YP. SEE SH TS. 15 & 16
12"x 22" CONCRETE METER
BOX WITH 3/16" STEEL DIAMOND PLATE
COVER EQUAL TO FOG TITE METER
SEAL CO. B-10 METER BOX.
(DRILL 1-3/eDIA. HOLE
SEE DETAIL A -A) 6" MIN
FINISH GRADE 9" MAX
NEW DUCTILE IRON I L LOOP DOWN TO CENTERLINE
WATERMAIN OF WATER MAIN TO PROVIDE
SLACK IN COPPER SERVICE
LINE TO METER.
CORPORATION STOP. FORD TAPERED
THREAD (CC). PACK JOINT �3/4" F1000)
(1 F1000)
EXISTING CAST IRON
OR DUCTILE IRON
WATERMAiN
.r
ELEVA TION
%2'
SERVICE FROM
_ PING STEEL
ASBESTOS CEMENT OR
PVC WATER MAINS
INSTALL DOUBLE STRAP
SERVICE CLAMP
EQUAL TO MUELLER CO.
W IN UNIMPROVED RIGHT OF WAY W
INSTALL METER BOX AT z
PROPERTY LINE. F
w
a SIDEWALK a
6
WATER METER TO BE 12" MIN
SUPPLIED BY THE CITY
36" MIN COVER
TYPE "K" SOFT
COPPER TUBING
FORD COPPERSETTER
VH 72-15W-44-33G FOR 5/8" x 3/4" METER)
VH 72-15W-44-44G FOR 1" METER)
BOTH INLET AND OUTLET WITH PACK JOINT WITH GRIPPER.
PADLOCK WINGS ON KEY VALVE SINGLE CHECK VALVE
ON OUTLET.
ALL PACK -JOINT FITTINGS SHALL BE WITH GRIPPER.
IF SERVICE LINE TO HOUSE IS TO BE
INSTALLED IN THE FUTURE INSTALL
FORD C14-33 OR 44
FIDT x COMPRESSION COUPLING
A -A DRILL 1- 314" DIA. HOLE FOR
NOTE TOUCHREAD DEVICE
THE CENTER OF THE HOLE JL
MUST BE AT LIEAST 1 " 2-1/2" MIN FROM NEAREST
FROM UNDERNEA 7H RIBS AND FROM T EDGE OF PIT LID
UNLESS 7HE RIB SPACING
ALLOWS THE NUT TO
TIGHTEN AGAINST THE OPEN TYPICAL RIB
SIDE OF MORE THAN
ONE RIB.
3/4" & 1N WATER SERVICE
BR41-TR
U10 0 Ap 0
ZETIM,d]
ati .5' M/N
ROOF DOWN SPOUT WITH
12 MIN ovERFLow
W Y AND
SPLASH
WASHED ROCK
J14 "0 TO 1-112"0
24"
SEC TION A - A
ROOF DOWN SPOUT INFIL TRA TION TRENCH
NO TES.
1. THE Cl TY OF RENTON ALLOWS INRL IRA TION TRENCHES ONL Y !MERE
THE CITY DEEMS IT FEASIBLE. APPLICANTS SHOULD INQUIRE IN WRITING
EARLY IN 7HE DESIGN PROCESS IF ROOF INFIL IRA TION WILL BE ALLOWED.
Z AT EACH TRENCH LOCA77ON A SOIL LOG AND PERCOLA77ON TEST IS
REQUIRED PER APPLICABLE DESIGN STANDARDS
J. FOR EACH TRENCH "L " MUST BE CALCULA TED PER APPLICABLE
DESIGN STANDARDS.
4. 7HE CI WL ENGINEERING PLAN MUST SPECIFICALLY SHOW EACH
INDIVIDUAL TRENCH LOCATION TO SCALE.
5. TRENCH LOCATIONS MUST NOT BE COMPACTED.
6. APPROVAL DEPENDS ON THE S17E SPECIFIC ENGINEERING REVIEW.
7. PIPE MATERIALS RECOMMENDED. PERFORATED PVC, POLYETHYLENE.
T��NCH lNFIL TRA TION SYSTEM