HomeMy WebLinkAboutWTR2703207.1WATER UTILITY - GENERAL NOTES WATER MAIN IF ADD[TIONAL ADJUSTMENT IS 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND REQUIRED, INSTALL 2-2' CLOSE GOOD HOMES NIPPLE AND 2-2' 90' BEND, SCREWED SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST AT THIS POINT, CL EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED BY FIELD LnCATE UNION z CONCRETE METER BOX THE CITY OF RENTON. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL r v - v AVE O 2' CLOSE NIPPLE - - - I I I PRE JI't J4,1 1 I PROD I PROP 395.0 TIMES DURING CONSTRUCTION. �- - 2' CLOSE NIPPLE 395.0-- i ' ; "' Gf�AIJf l�_ LINE ; LINE EXST 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM 2' 900 ELBOW--- . 2' 900 ELBOW 12' 3900 _ 2' GALVANIZED PIPE AS REQUIRED 390.0-- -- I _ - -- d EXIS I Ih1._._ I WTR TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE i s S TRANSPORTATION DIVISION AT 277-6222. ALL STREET CLOSURES, PARTIAL OR FULL, CONCRETE BLOCKING _ I .. _...._ _ ....._. _ 385.0 _ SHALL BE APPROVED BY THE TRANSPORTATION DIVISION AT 277-6222 24 HOURS IN PLAN 385 0 ; I _ __ �► i i ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE TWO PIECE CAST IRON VALVE NOTIFIED 24 HOURS IN ADVANCE. EQUAL TO OLYMPIC FOUNDRY CO, - GRtJUND LINE CONCRE LE SIDEWALK '3 0.0 ! i -_ ! NEW 4" 380.0 STANDARD 8' TOP SECTI❑N, WITH I I WTR tT1 REGULAR BASE SECTION LENGTH INAx, I I I I 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL- BE TO FIT. I THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT t 375.0 375.0 Yftft LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE MALL. 2-112" NST (HOSE) I uws / 1 NEW 8„ O STA 0 + 35 00' �-NM�+H x / � , � STA 0 - 15 00, �.00" N Z 48 HOURS LOCATORS, 1-800-424-5555. 2' GATE VALVE, SCREWED 6" TEE (MJ X FL) WTR NEW WET TAP 4 BLOW -OFF HYDRANT EQUAL TO 2° GALVANIZED 478 KUPFERLE FOUNDRY CO. 6" GATE VALVE EXST 12" x T TAPPING TEE (M.1 X FL) (FL X MJ) 24" SD 8" GATE VALVE (FLR-3 X MJ) 4 3 4. ALL WATER MAIN PIPE TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO PIPE 12' LONG FIRE HYDRANT Ati5FMF91 v EXST SEE DETAIL WTR-3 FOUND MON. IN CASE, 4"x4' AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT 2°x2'x2' TEE 36' � c,oNc;F2ETE W/1 3/4" PUNCHED r� 2' CLOSE NIPPLE BEWTEEN '= I n 8" X 4"' REDUCER (M I x pq_tl XST 8°' c� i BRASS DISK AT INTERSECTION OF MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST - - - - - - _- - TEE AND 90 ELBOW. 4" GATE VALVE (M J x M 11 SS 1IV f Fe N j UNION AVE NE AN& NE 21s` ST ' REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE 2° CLOSE NIPPLE BETWEEN CAP OR PLUG 2' 90 ELBOW E CLASS C. ALL DUCTILE IRON PIPE INSTALLED SOUTH OF SUNSET BLVD. (EMPIRE AND 2' 900 ELBOW _ INSTALL 4 MIL POLYETHYLENE 2' GALVANIZED PIPE 9 WAY, SR 900) AND WEST OF SR 167 ( EAST VALLEY FREEWAY) OR IN SOILS OF HIGH oa'-go �� oi, 18' LONG PLASTIC COVER OVER WASHED RESISTIVITY SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105-77 GRAVEL. CUT HOLE FOR PIPE °:� �° o�aa WATER ER PRU ILE Q STANDARDS. ter NAX. 0�0o,o6 e0000 2'P F �+'DR I_ia' �� �iOUTI� ooa .. *-� 0 o TA. F❑R DRAIN , I-a-r� - CITY OF RENTON CONT_R_OL N_O. 716 10 CU. FT. WASHED GRAVEL PASSING `--M} p 0 o 4-c o.n_0 SEE DETAIL WTR 4 ON SHEET 1 ! FOUND MON. IN CASE, 4"x4" 5. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE FOR D AND RETAINED ON 1i4' MESH As : � : � ;�u � �0 ��I 1 !OR(I7� L 3.001S - -CONCRETE Wl1"PUNCHED BRASS FOR DRAIN I �. STA C? + �5.00' h89�1'd 5` X DISK A-r INTERSECTION OF UNION , MATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C11 OIA21.10-82. DETAIL WTR `.'("AI I . ; r 6" TEE (MJ X FL) AVE NE AN& NE 19`" ST, 0.19' EAST �1 10 (-�� ER �. 6" GATE VALVE I i i OF SECTION LINE � CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/A.21.4-85. 1: _ OUT - �a�`^ '-LXMJ ' � m I_1�2MANEN i 2 BLOW CI- , o�.���L�MBi_`Y' ) ; �� I I FITTINGS ARE 3 INCHES TO 12 INCHES IN DIAMETER AND HAvi= MECHANICAL JOINTS, NO SCAI-F. FIRE HYDRANT ASSEMBLY I i THE FITTINGS SHALL BE IN ACCORDANCE WITH EITHER ANSI/AWWA C110/A21.10-82 93' X 4" REDUCER (MJ X MJ) I i 4" GATE VALVE (MJ X MJ) uR ANSI/AWWA C153/A21,53-84. 3 INCHES TO 12 INCHES DIAMETER FITTINGS WHICH � �7 HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE v m m c v m m < I I z G WITH ANSI/AWWA C110/A21.10.82 OR A COMBINATION OF ANSI/AWWA C110/A21.10.82 27' ACCESS i ; m o z m m AND ANSI/AWWA C153/A21.53-84 SUCH THAT THE PORTION OF TIME FITTING WITH A i NEW 3/" EASEMENT MECHANICAL JOINT(S), MAY BE IN ACCORDANCE WITH ANSI/AWWA C153/A21.53-84 _ WTRSVC (20' PAVED) `- `- DETAIL WTR-1 I _ _ AND THE PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ` f� 3� NEW 8" WTR MAIN I ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. ACCEPTANCE TESTING WITH k �0, i 50 LF 8" DI m m m m _.. _ ,�iE3t tt 09' 30" E 259.20' I 1 W U) SECTION 53.53 OF ANSI/AWWA C1531A21.53-84 OR WITH SECTION 10-4.3 OF 1 ANSI/AWWA C110/A21.10-82 SHALL BE OBTAINED BY THE CONTRACTOR AND `� - -- - b I a,. SS 0- 5 - STA G - 15 00• fiF''N TRANSMITTED TO THE OWNER. 1 l ►.I 1►J S .p. p t - cn NE t 4" WTR MAIN "'NEW WET TAP I 7 00 1 + 00' NEW F 4 DI too i 12" x 8" TAPPING TEE (MJ X FL) I t ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 4" CAP (MJ) W/ 2" TAP __ __. __ ___ _ ' 8" GATE VALVE (FL X MJ) z T> I m m 6A. A _ . _ . 2" PERMANENT BLOW S 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE + - _� - EE DETAILWTR-3 D z, o --I O n O OFF ASSEMBLY i I' o z z -- I -- ,r�l o-�c z N I NEW 8" SD Cl��/-6"`�• "oF "' SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH I `�' AmN �; _. - - - - - _ PRESSURE TESTING SHALL 8E DONE IN THE PRESENCE OF A --" ' - L _ z r- _ t N EXST s" p DEPARTMENT. ALL PRESS - - - - ' o Z D ap , = rn i 44 el i i i HYDRANT REPRESENTATIVE OF THE CITY OF RENTON. /- 6B. ALL WATER MAINS AND SERVICES SHALL F3E DISI�dFECTED BY THE INJECTION OF A 50 N `gin . NEW 9/." ±. NEW '/, �_ ' I i o WTRSVC c�fl' m p MINIMUM CONCENTRATION CHLORINE/WATER SOLUTION. DRY CALCIUM 1 I - WTF g�./L , 3 FxsT CB I A N 1 YPE 2) i D y P. M ( ) DETAIL WTR-1 ( , 1 \ DETAIL WTR-1 I NEW /� NEW ''" I f HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE Lll WTRSVC WTR`;VC �t OT 1 ' Y METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3 (12)E OR 7-11.3 (12) F OF DETAIL WTR-1 DETAIL WTI 1 �I Z' \�, o < THE STANDARDS SPECIFICATIONS REFERENCED IN 1 ABOVE. 00 i I I 7. A PRECONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A � I � 390 I � - MINIMUM OF 10 (TEN) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. l I I PRIOR TO SCHEDULING THE PRECON A PERMIT SHEET MUST BE SUPPLIED TO THE - ---1 w LOT 4 (LOT 3� _ .._ LpT ]2 UTILITY ENGINEER'S OFFICE. TWENTY FOUR HOURS NOTICE WILL BE REQUIRED I PRIOR TO STARTING NEW CONSTRUCTION. \ I I , EXST WTR METER I �=' 1 \ USE FOR LOT 2 cn r ' 8. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY �� SVC (OR REPLACE � i \ -� PERMITS PRIOR TO STARTING CONSTRUCTION. I � � Wl i-H NEW METER) ' I , 9. iNS T ALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL xj , N E DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, `, \ I'Jfif3 1 32" W 120.00 I i RECOMMENDED h� Jk NOT B FOR APPROVAL CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF a e RENTOhu. BY � 1--7,�oL&.. DATEtjA 9 o Q 10. ALL CONNECTION TO EXISTING MAINS TO BE ACCOMPLISHED BY THE CITY OF � � � \� « � \ a, RENTON, EXCEPT WET TAPS WHICH MAY BE MADE BY APPROVED WET TAP 1 l i x BY DATE CONTRACTORS WITH PRIOR APPROVAL FROM THE WATER UTILITY SECTION. ALL \ ! PROJECT NECESSARY EXCAVATION AND MATERIALS TO BE SUPPLIED BY THE CONTRACTOR ^- `' zn ! j ; B 614(/ �j s,e DATE � 6k-1511,eo4 AND BE ON PRIOR TO CITY NOTIFICATIONS. '� - ! I I I 1 11. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY 01 ' I BY DATE RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE CITY OPINION, ^ INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE 8" CAI' "WITh TEMP 12" X 8"' ~ ~ ~ i I ! U, „ ...,, � B Y DATE O CONTRACTOR AS WELL AS THE ENGINEERS SHALL KEEP AS -BUILT DRAWINGS, 2 BLOW OFF � � TAPPING TEE (113xfl) �"``�•, CONCRETE ` i2. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR NEW $°' WTR MAlry � i BLOCKING _\�\ =ol TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN., CITY (5 RE IN CONTROL N0. 894 Cy ` FOUND TE 11 CASE, NCH m 13. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS T� I CONCRETE W/1 1 T PUNCHED - ' ' i I ERA.SS DISK AT INTERSECTION OF 1$ MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OI#10 (?? ' UNION AVE NE & NE SUNSET BLVD, //�� l // Cn THE WATER UTILITY SECTION,. POLYPIG"-1 i 'I 0.03' EAST OF SECTION LINE _ C rn EQUAL APPROVED IN WRITING BY NOTE: MAINTAIN MIN 3F" COVER FOR ALL WATER MAINS � ! �� � � .� 0 8" TAPPING ':4. i-6PHALT AND CONCRETE STREET PAVING SHALL BE SAWCIJT TO A MINIMUM DEPTH VALVE EXST 12" ! i i i Cn OF TWO INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, WTR MAIN �I ' „ ! I �' I � i FOUND MON. IN CASE, 4"x4" , PAVEMENT, SIDEWALKS, CURBS, GUTTERS, AND DRIVEWAYS APPROACHES SHALL INSTALL 8 % i i CONCRETE AT NT" PUNCHED T. °� .� O BRASS DISK AT INTERSECTION OF `�' J J SOLID SLEEVE, G� i UNION AVE NE & NE 12"' STREET BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING 12 __ 8,r NIPPLES ,ExsT 12" EXPANSION JOINT. WATER SUPPLY PLAN __� ` �-_ .• 4 3 I i �f h',� SIZE 1 f) FIT WFR MAIN I D PATCH SHALL BE PLACED ON THE DAY OF INITIAL' 1:.. Y� 9 10 \ ✓' 15. A TEMPORARY COLD MIX ASPHALT P SCALE: 1 - 23' r EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF I RENTON POLICY WITHIN TEN DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO NEW 8" WTR 11 AiN - 1T PLACEMENT OF FINAL PATCH, TRENCHES WILL NOT BE LEFT OPEN OVER NIGI WITHOUT PRIOR WRITTEN APPROVAL OF THE INSPECTOR. - ' PVC PIPE SHALL BE 16. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE DETAIL WTR-3 SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 UNDER IMPROVED AREAS. WATER MAIN CONNECTION DETAIL_ �. JAMJES E HAYNES, P.E. ALL CHEMICAL LINES SHALL BE SCHEDULE 80 PVC PIPE. NO SCALE r? �� 3278QGQ .(r' 1822 109"Ave Ct E n m o �" r-�0 oviL CALL 48 HOUR5 Edgewood WA 98372 BEFORE YOU DIG Office (253) 568-7724 1-800-424-5555 Cell (206) 715-5159 I c l c f SCANNED APR 2 2