HomeMy WebLinkAboutWTR2703214.10ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT j LIGHTING FIXTURESIDEV►CES P&1D BUBBLE IDENTIFICATION CHART LADDER LOGIC SYMBOL LEGEND H. — CIRCUIT BREAKER XXX f YY - CB SIZE & N0. OF POLES ET - ELECTRONIC TRIP TM - THERMAL MAGNETIC BREAKER MCP - MOTOR CIRCUIT PROTECTOR SE -SERVICE ENTRANCE GFI - GROUND FAULT INTERRUPTER FUSE -° �--o FUSED DISCONNECT SWITCH PLUG-IN CONNECTION RTM RUN TIME METER EKI MOTOR OPERATION COUNTER SSRVS SSRVS -SOLID STATE REDUCED VOLTAGE STARTER SERVICE ENTRANCE, SWITCHGEAR, MOTOR CONTROL CENTER, OR PANELBOARD SURFACE MOUNTED PANELBOARD FLUSHED MOUNTED PANELBOARD NXX FIELD CONTROL STATION WITH NEMA � REQUIREMENTS. N1 -NEMA 1 N3R - NEMA 3R N4 - NEMA 4 N4SS -NEMA 4 STAINLESS STEEL N4F - NEMA 4 FIBERGLASS N6 - NEMA 6 I I � � ! J FLUORESCENT FIXTURE `' � �----(� WALL/CEILING MOUNTED FIXTURE I� ( ( f EMERGENCY LIGHT WITH SELF ! I I CONTAINED BATTERY SURFIXFACE OR PENDANT MOUNTED I � RECESSED FIXTURE i MD MOTION DETECTOR PC PHOTO CONTROL CELL EXISTING 'UNCTIONoF INDICATOR LIGHT INDICATOR LIGHT - A- AMBER G -GREEN kB - BLUE R - RED CLEAR e RELAY RELAY XYZ TR - Timed relay \123, CR - Control relay wesgr� 16727 $8GIs4:a�'° �IONAL SIGNED. 06129107 --� e INSTRUMENT IDENTIFICATION BUBBLE 0 FIELD MOUNTED DEVICE OR INSTRUMENT LIMIT SWITCH _ O LIMIT SWITCH, NORMALLY OPEN FLOAT SWITCH FLOAT SWITCH, NORMALLY OPEN ' — FRONT PANEL MOUNTED INSTRUMENT OR DEVICE (LOCAL PANEL) MIBLof WA L� 38613 ,ceGl$z8aa9ti rnaAL SIGNED. 06129107 -- BACK PANEL MOUNTED INSTRUMENT OR DEVICE (LOCAL PANEL) LIMIT SWITCH v LIMIT SWITCH, NORMALLY CLOSED ! FLOAT SWITCH FLOAT SWITCH, NORMALLY CLOSED -� FRONT PANEL MOUNTED INSTRUMENT OR DEVICE (LAB ROOM PANEL) TIME DELAY CONTACT -_ TIME DELAY CONTACT, NORMALLY OPEN, -�__ TIME TO CLOSE , - ^ PUSHBUTTON PUSHBUTTON, NORMALLY CLOSED OPERATOR INTERFACE DISPLAY (LOCAL PANEL) VARIABLE FREQUENCY DRIVE ^`' MOTOR STARTER MOTOR STARTER W/ OPERATOR �X DEVICES MCD A -HAND-OFF-AUTO B - OPERATIONAL COUNTER C - RUN TIME METER D -RUN LIGHT E - FAIL LIGHT F - EMERGENCY STOP KIRK KEY INTERLOCK O POWER TRANSFORMER CONTROL POWER TRANSFORMER TRANSFORMER CURRENT TRANSFORMER VOLTAGE TRANSFORMER T CONTACTOR CAPACITOR N12 - NEMA 12 GASKETED - EQUIPMENT MOUNTING STAND � HEATER HEATER, WATTAGE NOTED 15 kW ® EQUIPMENT CONNECTION SINGLE PHASE MOTOR. 1���' HORSEPOWER AS NOTED 100 THREE PHASE MOTOR. HORSEPOWER AS NOTED SINGLE PHASE MOTOR. HP HORSEPOWER AS NOTED GE ELECTRICAL PLUG AMPS DISCONNECT SWITCH (AMPERAGE NOTED) FUSED DISCONNECT SWITCUj H COMBINATION MOTOR STARTER � AND DISCONNECT SWITCH' (T) PROGRAMMABLE TIMER I OPERATOR INTERFACE DISPLAY (LAB ROOM PANEL) TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO OPEN � PUSHBUTTON i PUSHBUTTON, NORMALLY OPEN O � Y � � „L FIRE SYSTEM SYMBOLS INDICATE TYPE BY LETTER INSTRUMENT METER H� HEAT DETECTOR � SO SMOKE DETECTOR � FIRE ALARM DISPATCH STROBE ALARM RA FIRE ALARM AUDIBLE/VISUAL ALARM ® FIRE ALARM MANUAL PULL STATION V j AM � AM - AMMETER VAR - VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER PFM - POWER FACTOR WM - WATTMETER + VM - VOLTMETER WH - WATTHOUR METER VA -VOLT AMMETER TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY OPEN, `1 TIME TO OPEN THERMOSTAT THERMO SWITCH, NORMALLY OPEN TIME DELAY CONTACT - TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO CLOSE Imo. THERMOSTAT THERMO SWITCH, NORMALLY CLOSED FACILITY RACEWAY LEGEND � p` .s Q z W J J Q 15rlff pi -AN LEG)ENO SEE DWG N0. G02 FOR PROPOSED SITE LEGEND ONE -LINE OIAGhAM EXISTING CONDUIT AND CONDUCTORS 480 VOLT WIRING GROUND WIRING ou/I OINO O' F�GIUrY PLAN LEOYNO EXPOSED RACEWAY I - — — - CONCEALED IN WALL OR CEILING CONCEALED IN OR BELOW FLOOR UNDERGROUND CONDUIT GROUND WIRING _ HOME RUN TO PANELBOARD OR AS INDICATED ADDITIONAL SYMBOLS RELAY CONTACT, NC RELAY CONTACT, INSTANTANEOUS CHANGE RELAY CONTACT, NO FLOWSWITCH FLOWSWITCH, NORMALLY OPEN S SOUND SYSTEM SPEAKER i ,V, SOUND SYSTEM VOLUME CONTROL DOORBELL PRESSURE SWITCH I PRESSURE SWITCH, NORMALLY OPEN FLOWSWITCH n FLOWSWITCH, NORMALLY CLOSED VALVE SYMBOLS PILOT VALVE SOLENOID VALVE ! CHECK VALVE �1 PRESSURE SWITCH I PRESSURE SWITCH, NORMALLY CLOSED 2 POLE SWITCH _ ----- RECEPTACLES AND JUNCTION BOX SYMBOLS j ENGINE GENERATOR GENERATOR CONNECTION RECEPTACLE S N SOLID NEUTRAL TB TERMINAL BLOCK TRANSIENT VOLTAGE SURGE SUPPRESSOR TVSS TRANSIENT VOLTAGE SURGE 0 01 SUPPRESSOR (ALTERNATIVE) 0 GROUND BLOCK NEUTRAL BLOCK CEILING JUNCTION BOX J WALL JUNCTION BOX FLOOR JUNCTION BOX DUPLEX WALL RECEPTACLE , 120V WP =WEATHERPROOF G =GROUNDED IG = ISOLATED GROUND GF = GROUND FAULT INTERRUPTER DOUBLE DUPLEX _e SINGLE RECEPTACLE, 120V SINGLE RECEPTACLE, 208V ® DUPLEX FLOOR RECEPTACLE, 120V CONTROL VALVE CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED FLEXIBLE CONDUIT III CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS CALLOUT INDICATING CONDUIT SIZE, NUMBER AND SIZE OF WIRE, �" GRC, 2-#12 � ALLOUT INDICATING CONDUIT PER SCHEDULE 100 CONDUIT BENT UP OR TOWARD CONDUIT BENT DOWN OR AWAY ] CAPPED CONDUIT I z_ 1 3 POLE SWITCH -- - ? - M� V W W PID FORMAT SUPERSCRIPT � X=MEASURED OR INITIATING VARIABLE �� XYZ Y_READOUT OR FUNCTION Z=MODIFIER ABC ABC=LOOP NUMBER INSTRUMENT BUBBLE ABBREVIATIONS 1P - 1 POLE 1PH -SINGLE PHASE NEMA -NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION 2P - 2 POLE N.L. - NIGHT LIGHT 2PH - TWO PHASE mA - MILIAMP 3P - 3 POLE MCC - MOTOR CONTROL CENTER 3PH - THREE PHASE MCM - ONE THOUSAND CIRCULAR MILS AF - AMP FRAME P - POWER AH - AMP HOUR PB - PANIC BUTTON AL - ALUMINUM PC - POWER & CONTROL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS F — POWER FACTOR AT — AMP TRIP PNL — PANEL ATS -AUTOMATIC TRANSFER SWITCH PSE - PUGET SOUND ENERGY ISA STANDARDS FOR P&ID ( 1st LETTER (MEASURED 12nd LETTER (READOUT] 3rd LETTER OR INITIATING VARIABLE) ` OR FUNCTION) I (MODIFIER) ELECTRICAL & SIGNAL PLAN DEVICES SOLENOID VALVE COIL LE LEVEL ELEMENT e SPECIAL PURPOSE WALL RECEPTACLE, A B ANALYSIS i ALARM I BURNER E I BPS - BOOSTER PUMP STATION PVC - POLYVINYL CHLORIDE CONDUIT C CONTROL PWR POWER POWER POWER METER METER � GENERATOR BLOCK HEATER RATING AS NOTED O CLOCK TV TELEVISION C D E F G H COMMUNICATION I CONTROL I CLOSED DENSITY , VOLTAGE ' - - - - - - - -I- - - - - - - - L - - - - - - FLOW { FAIL GAS I i GREEN BULB HAND I MANUAL {HIGH () MV MOTORIZED VALVE COIL HE HEATING ELEMENT FS FLOAT SWITCH PS PRESSURE SWITCH _ - CJ CONTROL & INSTRUMENTATION RECP RECEPTACLE CKT - CIRCUIT SPDT - SINGLE POLE, DOUBLE THROW CO - CONDUIT ONLY SPST - SINGLE POLE, SINGLE THROW CR -CONTROL RELAY SSRVS -SOLID STATE REDUCED VOLTAGE STARTER CTRL - CONTROL SUSE - SUITABLE FOR USE AS SERVICE ENTRANCE CU - COPPER TB - TERMINAL BLOCK DPST -DOUBLE POLE, SINGLE THROW TEMP -TEMPERATURE maii0.720.8052 1.800.?2o.eo52 - PROPOSED EQUIPMENT - - ENCLOSURE TELEPHONE TELEPHONE/DATA WITH CABLE J rK' CURRENT j INDICATE ; POWER - -I - - - - - - I- - - - - TIME I CONTROL STATION LS LIMIT SWITCH T! TEMPERATURE INDICATION OPB PANIC BUTTON TS TEMPERATURE SWITCH EG _ ENGINE GENERATOR TVSS _ TRANSIENT VOLTAGE SURGE SUPPRSSOR GFI GROUND FAULT INTERRUPT TYP, TYPICAL GRC - GALVANIZED RIGID CONDUIT U.L. - UNDERWRITERS LABORATORIES HOA -HAND-OFF-AUTO VAC -VOLTS AC AFI r 1# AM OFFICE for Road EXISTING EQUIPMENT ENCLOSURE TELEPHONE DATA WITHOUT CABLE / L M N 0 Q R S T U V W X Y LEVEL I LIGHT ! LOW I MOTION MIDDLE USERS CHOICE I I USERS CHOICE I I OPEN - - - —i— - - - - ---- - - �- - - - - - QUANTITY I TOTALIZE RADIATION i RECORD I RED BULB SPEED I SWITCH I SOLENOID TEMPERATURE j TRANSMITTER 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ MULTI VARIABLE -` MULTI FUNCTION - i VALVE I VISCOSITY WEIGHT I j UNCLASSIFIED I USERS CHOICE I RELAY I - - - - - - - -i- - - - - - - - �- - - - - - - T T THERMOSTAT SWITCH ZS INTRUSION SWITCH (LE) FLOW ELEMENT AE ANALYSIS ELEMENT HP - HORSE POWER VCP - VOLTS CONTROL POWER KAIC - THOUSAND AMP INTERRUPTING CAPACITY VDC - VOLTS DC KVA - KILOVOLT AMP VFD - VARIABLE FREQUENCY DRIVE KVAR - KILOVOLT AMPS REACTIVE W - WATT KW - KILOWATT WP - WEATHER-PROOF NEC - NATIONAL ELECTRIC CODE WSDOT - WASHINGTON STATE DEPARTMENT OF TRANSPORTATION '■ 3 2 143 3 7)FFICE 95ti^. Street, Suite 100 ` wia�e OFFICE 09.8862900mor,, ""OQ Smarr Street, Suite 5 PORE OFFICE - GROUNDING SYSTEM SYMBOLS SWITCH OUTLETS 1 GROUND _ METAL PIPE GROUND CONNECTION POINT EXOTHERMIC WELD. �— CADWELD OR APPROVED EQUAL. GROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. S STANDARD SWITCH, 120VAC, 20 AMP S 3-WAY SWITCH, 120VAC, 20 AMP `=J 3 3WAY 3-POSI1ION SWITCH, 120VAC, 20 AMP, S LABEL SWITCH POSITION HOA HOA HAND -OFF -MOTION OR PHOTO GENERAL NOTES 1, THIS IS A STANDARD LEGEND, NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL APPEAR IN THIS SET OF PLANS, I 2, THESE DRAWINGS ARE DIAGRAMMATIC ONLY. EXACT LOCATIONS OF ELECTRICAL EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL i APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND , - VERIFY THEIR REQUIREMENTS. SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG S SINGLE -POLE � PILOT -LIGHTED REVISED TO CONFORM PLOT: 1 DWG NO. E01 PIGTAIL, BARE COPPER, LENGTH AS REQUIRED, 8' MINIMUM. CONNECTION POINT, MECHANICAL, COMPRESSION TYPE. DEE DOUBLE -POLE S THREE WAY 3 S FOUR WAY P S� KEY -OPERATED S LOW VOLTAGE LV S MASTER Z POSITION I I I j j I i I 3. N01IFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS. LACK OF INFORMATION OR ANY OTHER REASON, NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER.7 TRUC ION CORDS r 06 08 09 ENGINEER: CMR REVIEWED: MLM RH ENGINEERING INC. DATE DATE: SEP 14, 2009 SHEET N0. RECORDS DY KJS 06/08/09 4 S DIMMER M PUSHBUTTON i I I I I I REVISED TO CONFORM TO CONSTRUCTION ADDENDUM /ISSUED FOR CONSTRUCTION CLIENT, REN roe No.: 105 049 105- 27 34 SITE PLAN SYMBOLS I BTE MM 10/09/07 SEE COVER SHEET. NO. REVISION BY REVIEW DATE FILENAM2 HAZEN-D-ELECOI 01101111 0LI,^ "`I