Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703214.12
PROPOSED ELECTRICAL ENCLOSURE, (TYP. OF 6) ah 577,92' Mv LANDING PLATFORM ELEVATION Lrd,_ •• 1IIIIIIIIII - , PROPOSED CABLE CONDUITS AND CONDUIT SUPPORTS BELOW SPIRAL STAIRWAY CENTERLINE OF (2) PROPOSED POWER CONDUITS TO RESERVOIR ROOF FOR POWERING PROPOSED RESERVOIR ROOF LIGHTING, RESERVOIR INTERIOR LIGHTING, RESERVOIR STAIRWAY LIGHTING, RESERVOIR ROOF RECEPTACLE, AND SEWER TELEMETRY RECEPTACLE. SEE RESERVOIR ROOF ELECTRICAL PLAN, THIS SHEET, FOR MORF INFORMATION SEE DWG NO. E _ RESERVOIR INTERIOR ACCESS HATCH. © INSTALL PROPOSED INTRUSION SWITCH ON ACCESS HATCH. RESERVOIR ROOF ACCESS PLATFORM f RESERVOIR SPIRAL STAIRWAY f 'ESERVOIR INTERIOR LANDING PROPOSED RESERVOIR LEVEL TRANSMITTER. SEE DWG NO. E04 FOR DETAIL. O RESERVOIR ROOF INTERIOR HANDRAIL PROPOSED RES_ --'l VO1R ROOF EXTERIOR F 'µ:IL PROPOSED ELECTRICAL PROPOSED ELECTRICAL ENCLOSURE, (TYP. OF ENCLOSURE, (TYP. OF 6) 6). SEE DETAIL THIS RESERVOIR SHEET. INTERIOR $ LADDER 8 PROPOSED RESERVOIR TELEMETRY JUNCTION d BOX NO. 1. SEE DETAIL THIS SHEET KO OVERFLOW PIPE A J10 C11 - 03 PROPOSED CONDUITS SECURED TO PROPOSED UNISTRUT ON OVERFLOW LEVEL RESERVOIR EXTERIOR. FLOAT SWITCH CONTRACTOR SHALL SECURED TO WELD A 1 1" RESERVOIR UNISTRUT CHANNEL INTERIOR LADDER, TO THE EXTERIOR OF SEE DWG N0, THE TANK EVERY 8' E04 FOR DETAIL. FOR SECURING CONDUIT. PROPOSED EXTERIOR STAIRWAY LIGHT FIXTURE, TYP. OF 3. MOUNT FIXTURE TO STAIRWAY RAILING. SEE DETAIL ON DWG NO, E06. PROPOSED CONDUIT SECURED BELOW RESERVOIR EXTERIOR STAIRWAY 03 1 Pl4 .0 r------------- REVISED TO CONFORM _T,Q CONSTRUCTION CORD /08/09 DATE ,STRUCTn'.n' QFCORDS CONSTRUC NO REVISION DY KJS 06/08/09 BTE MM 10/09/07 BY REVIEW DATE ELECTRICAL ELEVATIOK PROPOSED CONDUIT AND CONDUCTORS FOF PROPOSED RESERVOIR LEVEL TRANSMITTER, ACCESS HATCH INTRUSION SWITCH, AND RESERVOIR % OVERFLOW LEVEL f FLOAT SWITCH. SEE RESERVOIR ROOF ELECTRICAL PLAN AND DWG NO. E04 FOR MORE INFORMATION. PROPOSED LIMIT SWITCH INSTALLED ON LOWER ACCESS PLATFORM ACCESS HATCH. CONTRACTOR SHALL PROVIDE LEVER ARM BEST SUITED FOR THIS APPLICATION. LIGHTS SHALL TURN ON WHL ACCESS HATCH IS OPENED. — CABLE TRAY RESERVOIR LOWER ACCESS PLATFORM I ----' RESERVOIR VANDAL SHIELD PROPOSED VANDAL SHIELD INTRUSION SWITCH. SEE DETAIL ON r� THIS SHEET. J9 J1 J8 C4 CC —5) „ n TO ELECTRICAL BUILDING WEATHERPROOF ON/OFF S41TCH FOR EXTERIOR LIGHT. SECURE TO ROOF ACCESS RAILING WITH STAINLESS STEEL HARDWARE. INSTALL CONDUIT TO JUNCTION BOX BENEATH GRATING. PROPOSED RESERVOIR TELEMETRY JUNCTION BOX NO. 2 MOUNTED TO ACCESS PLATFORM RAILING. SEE DETAIL ON DWG NO. E04. CENTERLINE OF (2) PROPOSED P13 POWER CONDUITS TO ELECTRICAL BUILDING. SEE RESERVOIR ELECTRICAL ELEVATION FOR CONTINUATION. ACCESS HATCH TO RESERVOIR INTERIOR PROPOSED LIGHT FIXTURE, "AY, AND POLE SECURED TO RAILING WITH STAINLESS STEEL HAR:' RARE. DIRECT LIGHT FIXTURE T _;'NARD ACCESS HATCH. SEE DWG '<: E05 MOUNTING BRACKET WELDED TO FOR LIGHT FIXTURE SC EDULE. TANK INTERIOR ROOF RESERVOIR ROOF ACCESS PLATFORM LOCATED ON —, TANK INTERIOR ROOF RESERVOIR ROOF PROPOSED TANK INTERIOR LIGHT PROPOSED SHOCK FIXTURE. MOUNT FIXTURE NEXT TO MOUNT BASE KIT FOR ` ACCESS HATCH. CONTRACTOR TO ENSURE FIXTURE IS ACCESSIBLE ROTATING LIGHT FOR MAINTENANCE PURPOSES. FIXTURE. SEWER TELE - RY GFCI RECEPTACLE m wdr Q�CtsTatz6° CENTERLINE OF PROPOSEDI�vnL1 TELEMETRY CONDUITS TO RESERVOIR TELEMETRY JUNCTION BOX NO. 1. SIGNED. 06129107 SECURE CONDUIT TO RESERVOIR EXTERIOR T RAILING. of WASL , 2" POWER CONDUIT T ELECTRICAL ENCLOSUE �► - 38613 it Alf c JUNCTION BOX SECURED wv-W, ,rod TO INSIDE OF RAILING WITH STAINLESS STEEL SIGNED. 06129107 HARDWARE, WEATHERPROOF ON/OFF SWITCH FOR INTERIOR LIGHT. SECURE TO INSIDE OF RAILING WITH STAINLESS STEEL HARDWARE. GFCI RECEPTACLE IN NEMA 4X STAINLESS STEEL ENCLOSURE WITH QUICK HASP LATCHES. SECURE TO RAILING WITH STAINLESS STEEL HARDWARE. RESERVOIRACCESS TO MOUNTING DETAIL RESERVU"IR ROOF ACCESS PLATFORM ELECTRICAL PLAN NOT TO SC.Al—F- VANDAL SHIELD INTRUSION SWITCH. CONTRACTOR SHALL PROVIDE LEVER ARM BEST SUITED FOR THIS APPLICATION. CONTACT SHALL BREAK WHEN SHIELD IS OPENED. �J CONDUIT AND WIRING TO RESERVOIR TELEMETRY PANEL. ROUTE CONDUIT INSIDE VANDAL SHIELD. /— ROOF ACCESS LADDER NOT TO SCALE VANDAL SHIELD PROPOSED NEMA 4X FIBERGLASS, , 14' X 12" X 6", ENCLOSURE SECURED TO r THICK SS PLATE WITH J" STAINLESS STEEL HARDWARE. SECURE SS PLATE TO TANK SIDE OF RESERVOIR EXTERIOR PROPOSED NEMA 4X FIBERGLASS, 12" X RAILING IN 4 LOCATIONS USING (3) 4" SS BOLTS. 12" X 6", RESERVOIR TELEMETRY THE ENCLOSURE SHALL BE AN ADALET, JUNCTION BOX NO. 1 SECURED TO N4X—FG-141206CHSC WITH MOUNTING PANEL, THICK SS PLATE WITH 4" STAINLESS BP1412A, OR EQUIVALENT ENCLOSURE. THE % STEEL HARDWARE. SECURE SS PLATE TO PROPOSED ENCLOSURE IS TYPICAL OF (6) TANK SIDE OF RESERVOIR EXTERIOR ENCLOSURES TO BE MOUNTED TO THE TANK SIDE RAILING IN 2 LOCATIONS USING (3) J" SS OF THE RAILING AROUND THE RESERVOIR. THE BOLTS PROPOSED ENCLOSURES SHALL BE INSTALLED AT EQUAL INTERVALS AROUND THE RESERVOIR RAILING. Jt PROPOSED 2" SCHEDULE 80 PVC A 2 SCHEDULE 80 PVC CONDUIT SHALL BE / CONDUIT WITH PULL STRING SECURED INSTALLED BETWEEN EACH ENCLOSURE. TO TANK SIDE OF RESERVOIR RAILING ,! WITH STAINLESS STEEL HARDWARE. INSTALL PROPOSED CONDUIT BETWEEN TO PROPOSED ELECTRICAL ', � EACH ENCLOSURE. ENCLOSURE, (TYP. OF 6) �' � TO PROPOSED ELECTRICAL ENCLOSURE, (TYP. OF 6) TO PROPOSED JUNCTION PROPOSED 2" SCHEDULE BOX LOCATED NEXT TO 80 PVC CONDUIT WITH RESERVOIR INTERIOR PULL STRING SECURED TO ACCESS HATCH. SEE TANK SIDE OF RESERVOIR RESERVOIR ROOF ACCESS RAILING WITH STAINLESS PLATFORM ELECTRICAL STEEL HARDWARE. PLAN FOR MORE INSTALL PROPOSED INFORMATION. SECURE CONDUIT BETWEEN EACH J9 — C4 J10 CONDUITS TO TANK SIDE C11 ENCLOSURE. OF RAILING WITH ELECTRICAL NCB TE S 1 J1 STAINLESS STEEL CONDUITS STACKED J9 J8 HARDWARE. BEHIND EACH OTHER J9 J8 PROPOSED CONDUITS SECURED TO EXTERIOR OF RESERVOIR. TO PROPOSED \ CONTRACTOR SHALL SECURE PROPOSED CONDUITS TO ELECTRICAL BUILDING UNISTRUT EVERY 8' WITH STAINLESS STEEL HARDWARE. SEE CABLE TRAY DETAIL ON DWG NO. S08 FOR MORE INFORMATION. 1. SEE DWG NO. E05 FOR ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE. 2. SEE DWG NO. E05 FOR CONDUIT AND CONDUCTOR SCHEDULES. 3. SEE LIGHTING FIXTURE SCHEDULE ON DWG NO. E05. 4. CONTRACTOR SHALL INSTALL PROPOSED CONDUITS BETWEEN ELECTRICAL BUILDING AND RESERVOIR ROOF IN PROPOSED CABLE TRAY. 5. CONTRACTOR SHALL INSTALL PROPOSED CONDUITS BETWEEN ELECTRICAL BUILDING AND RESERVOIR ROOF BELOW RESERVOIR STAIRWAY. 6. INTERIOR RESERVOIR LIGHT FIXTURE, "A4", MOUNTED TO RESERVOIR INTERIOR ROOF. PENETRATE RESERVOIR ROOF WITH RIGID CONDUIT BETWEEN LIGHT SWITCH AND FIXTURE AND SEAL WATERTIGHT. 7. PROPOSED TELEMETRY CONDUITS TO RESERVOIR INTERIOR. INSTALL RIGID CONDUITS BENEATH GRATING TO ACCESS HATCH PENETRATION. SEAL ACCESS HATCH PENETRATIONS WATERTIGHT. SEE DWG NO. E04 FOR CONTINUATION IN RESERVOIR INTERIOR, 8. PROPOSED 2" SCHEDULE 80 PVC CONDUIT SECURED TO RAILING. W=321435 --- - 1 j2' = 1 0" � 0:4 -4 U 1- -1 m AMA I> sEER!. p RH2 ENGINEERING. INC. i ttp:,///www.rh2.com -)ailbox@rh2.com 800.720.8052 3ELLINGHAM OFFICE 60.676.0836 54 West Horton Road 30THELL OFFICE • 25A51.5400 2100 NE 195th Street, Suite 100 BAST WENATCHEE OFFICE 09.886.2900 100 Simon Street, Suite 5 TORT ORCHARD OFFICE 60.876, 7960 600 Kitsap Street, Suite 101. SCALE: SHOWN 0 1> 2" DRAWING IS NOT TO SCALE BAR IS NOT 2" LONG 96 DWG NO. CMR E03 MLM -)tP i4, 2009 29 cuEN . REN —7 Joe No 105-049 FILENAME: HAZEN—D—ELEC03