Loading...
HomeMy WebLinkAboutWTR2703214.26PROPOSED POND MAINTENANCE ACCESS ROAD PROPOSED 8" CULVERT PROPOSED QUARRY SPALLS PROPOSED WATER QUALITY SAMPLING STATION, SEE/`p� FOR DETAILS PROPOSED ACCESS CORRIDOR AND OPEN SPACE FOR FUTURE CELLULAR EQUIPMENT, SEE/-F---\FOR DETAILS SEE DWG NO. G01 FOR SURVEY AND STATION LINE CONTROL POINTS i PROPOSED POND OUTFALL PA-u : E B` FOR DETAILS PROPOSED 450 CHAIN -LINK APPROX. 94 LF OF FENCE ~ CPEP POND OUTFALL APPROX. STA, 3+27.3, 172.5' R, PIPE, ROUTE TO - PR`OSE v APPROX, STA. 3+23.3, 12.9' R, PROVIDE: POND OUTFACE PIPE O PROVIDE: 44 ;> (1y - 12" DI 90- BEND (MJxMJ) WITH 452 (1) 12" DI 90- BEND (MJxMJ) -,',-PAD AS SHOWN - - k ,7-1 . w w w „ w w w APPROX 160 LF of 12 D1 PIPE 4,ga PROPOSED GRAVEL ACCESS qSA �S ROAD, SEE E FOR rn f DETAILS C04 PROPOSED POND FENCE PROPOSED ACCESS 2 ROAD DRAINAGE PROPOSED POND OVERFLOW .. SPILLWAY, SEE FOR DETAILS - -- -• CATCH BASIN, SEE C DWG NO. C12 FOR o PROPOSED C04 DETAILS STORMWATER 12" � POND INLET PIPE, SEE DETENTION POND X DWG NO. C12 FOR DETAILS , PROPOSED POND PROPOSED POND CONTROL _ - -- - OUTFACE CATCH BASIN, x STRUCTURE, SEE D FOR DETAILS 5 SEE DWG NO. C12 FOR DETAILS ` 18" POND INLET PIPE, SEE DWG PIPE CROSSING, SEE h �+ NOS. C12 & M01 FOR L).E i AILS 2 �'50 f PROPOSED AIR -GAP STRUCTURE, APPROX 119 LF of NOTE THIS SHEET ` SE A OR DETAILS WALL FOOTING 13 12' DI PIPE i DRAIN I PROPOSED RESERVOIR DE('HLORINATION \\j{ 449 _ VAULT, SEE DWG NO. M01 FOR DETAILS ;x `F PROPOSED 12" RESERVOIR DRAIN\OVERFLOWS APPROX. STA. 2+08.9, 179,6' R, PROVIDE-0 PIPE, SEE DWG NO. M01 FOR DETAILS (1) - 12" DI 221/2' BEND (MJxMJ) WITH VALVE MARKER, (TYP. OF 4) j THRUST BLOCK 1 3 SE A FOR DETAILS I co �Ss . 452 j` 'ROPOSED 42" RESERVOIR RFLOW PIPE, } ~ K SEE DWG NO. M01 FOR DETAILS �D s `I '+, - APPROX 61 l r . ,,� Jr of 12" DI454 r PROPOSED SEISMIC ISOLATION VALVE VAAULT, SEE DWG NC. In ��02, FOR DETAILS '`PROPOSED VAULT DRAIN LINE, BLOW OFF AWS SPLASH PAD, SEE `E�x RESERVOIR OR DETAILS OVERFLOW, SEE DWG NO. M01, C15 i FOR DETAILS �s I RESERVOIR DRAIN„ f S V SEE DWG NO. M01 RESERVOIR FOR DETAILS RINGl APPROX. STA. 1+53,2, 204.8' R, PROVIDE: (1) - 12" DI 221/2' BEND (MJxMJ) WITH THRUST BLOCK APPROX 39 LF of 12" DI PIPE PROPOSED BUILDING PAD FOR ELECTRICAL BUILDING, SEE ` P DETAILS ;4 PROPOSED 10'x16' PRE -CAST ELECTRICAL BUILDING. SEE DWG NO. E02 FOR DETAILS. , APPROX 14 LF of 16" DI PIPE, (FLxPE) APPROX. STA. 1+14.3, 205.8' R, PROVIDE: (1) - 12" DI TEE (FLxFL) (2) - 12" DI GATE VALVE (FLxMJ) (1) - 12" DI GATE VALVE (FLxFL) (1) - 16" x 12" DI REDUCER (FLxMJ) APPROX, STA. 0+85.7, 222.0' R, PROVIDE: (1�,,=- HYDI NT ASSEMBLY, PER CITY STANDARD DtT-XI­L T02- w APPRXX 116 LF w 0 2 L A� 6' SECTION SE 03, TOWNSHIP 23. RANGE 05 i, r POSED HOQUTAM SUBDIVISION PIPE CROSSING NOTE: PROVIDE VERTICAL BENDS OR DEFLECT WATER MAIN TO ALLOW WATER MAIN TO PASS BELOW OUTFALL PIPE. PROVIDE 6" MIN. CLEARANCE BETWEEN PIPES, PLACE NEOPRENE PAD BETWEEN PIPES AT CROSSING. 'OPOSED ELECTRICAL UTILITIES )T SHOWN, SEE DWG NO. C15 )R PROPOSED ELECTRICAL SITE .AN. 'OPOSED LANDSCAPING NOT SOWN, SEE DWG NO. C07 FOR 'OPOSED SITE AND LANDSCAPII APPROX. STA. 0+72.0 322.3' R, PROVIDE. � APROX. A. 0+9 2, 206 8' R, PROVIDE(1) - 12" DI CROSS (FLxMJ), VERTICAL FOR (1) - 12" TEE (MJxFL) POLYPI2fGiBGOWPER OFFCITY ASSEMBDAREDEAIY B114 R CIT (1) - 12" GATE VALVE (FLxMJ) APPROX- STANDARD DETAIL B105 46.0 (1) - 12" PLUG WITH THRUST BLOCK RELOCATE GUY WIRE TO AVOID CONFLICT WITH PROPOSED FENCE. COORDINATE WITH UTILITY FOR RELOCATION` 46 } 46 �6? NE 12TH ST (ROAD EA SEMENT) CITY PROJ. NO, W-2851, STA. 25+94 EXISTING CITY WATERLINE PROJ. NO. W-2851 APPROX. 255' -321414 CONSTRUCTION ACCESS ENTRANCE 01 0 C i 1_ 4e t eIT�F' ,'., A8-• U SIGNED: 06129107 6 38613 f� ft IS T SO SIGNAL 44 4` SIGNED. 06129107 N ' N z y NlotN OP ` 3 rn r rT, w O w - ,h : Apr, T'1' `-I _ (-TION RECORDS DY KJS 06/08/09 P: #13 - INLET & - =' ';"_ `: ='' KMP "1 01/22/08 ADDENDUM / ISSUED FOR CONS", TRUCTION BTE �1-1h1 10/09/07