HomeMy WebLinkAboutWTR2703214.28PROPOSED POND MAINTENANCE ACCESS ROAD OUTLINE OF RESERVOIR FOOTING PROPOSED ACCESS ROAD PROPOSED ACCESS CORRIDOR AND OPEN SPACE FOR FUTURE CELLULAR EQUIPMENT PROPOSED C.'HAIN-LINK - PROPOSED .ACCESS GATE MOTOR OPERATOR PROPOSED GATE ENTRY KEYPAD AND PEDESTAL, SEES, �b FOR DETAILS, STUB UP TELEMETRY CONDUIT TO KEYPAD FOR FUTURE USE. PROPOSED BUILDING PAD FOR ELECTRICAL BUILDING, SEE�� FOR DETAILS PROPOSED 10'xl6' PRE -CAST ELECTRICAL BUILDING. SEE DWG NO. E02 AND SPECIFICATIONS FOR DETAILS. j4 7 IIIIIIIII01 4t� LOCATE CLEAR OF PROPOSED FENCE 0- Aaft '00w 40w, w ww., 6 /10 4 SE 03, TOWNSHIP 23, RANGE 05 ELECTRICAL NOTES 1. SEE DWG NO. E05 FOR CONDUIT AND CONDUCTOR SCHEDULES, 2 2, PROPOSED PAD -MOUNT TRANSFORMER PROVIDED AND INSTALLED BY ELECTRICAL UTILITY. CONTRACTOR SHALL PROVIDE EXCAVATION AND RESTORATION FOR INSTALLATION OF PAD -MOUNT TRANSFORMER AND TRANSFORMER VAULT PER PUGETSOUND ENERGY REQUIREMENTS, ELECTRICAL UTILITY SHALL PROVIDE AND INSTALL PAD -MOUNT TRANSFORMER AND VAULT. ELECTRICAL UTILITY SHALL CONNECT CONDUCTORS TO THE PRIMARY AND SECONDARY SIDE OF THE TRANSFORMER. F 13 335, PROPOSED OUTDOOR AREA LIGHT. SEE DWG NO. E06 FOR OUTDOOR AREA LIGHT DETAILS. i A 4, EXISTING UTILITY POLE. ELECTRICAL UTILITY SHALL INSTALL CONDUIT AND CONDUCTORS ON EXISTING UTILITY POLE BETWEEN THE PRIMARY POWER CONNECTION ON THE TOP OF THE POLE AND THE PROPOSED PRIMARY POWER HANDHOLE AT THE BASE OF THE POLE, THE ELECTRICAL UTILITY SHALL PROVIDE AND INSTALL A PRIMARY POWER HANDHOLE AT THE BASE OF THE POLE. THE CONTRACTOR SHALL PROVIDE EXCAVATION AND RESTORATION FOR INSTALLATION OF HANDHOLE, THE ELECTRICAL UTILITY SHALL PROVIDE AND INSTALL PROPOSED PRIMARY POWER CONDUIT AND CONDUCTORS FROM PRIMARY HANDHOLE TO THE PROPOSED PAD -MOUNT TRANSFORMER. TRENCHING, BACKFILL, AND RESTORATION SHALL BE PROVIDED BY THE CONTRACTOR PER PUGE T SOUND ENERGY REQUIREMENTS. CONTRACTOR SHALL COORDINATE ALL WORK WITH PUGET SOUND ENERGY. 5 5. PROPOSED SPARE CONDUIT WITH PULL STRING TO PROPOSED ACCESS GATE ENTRY KEYPAD, CAP AND STUB -UP CONDUIT BELOW KEYPAD. 6, EXISTING GUY WIRE. CONTRACTOR SHALL RELOCATE EXISTING GUY WIRE FOR INSTALLATION OF PROPOSED FENCE. CONTRACTOR SHALL COORDINATE WITH ELECTRICAL UTILITY FOR GUY WIRE RELOCATION. CONTRACTOR SHALL PERFORM ALL REWORK REQUIRED FOR RELOCATION OF EXISTING GUY WIRE. . PROPOSED SPARE CONDUIT WITH PULL STRING BETWEEN UTILITY POLE AND ELECTRICAL BUILDING, CAP AND STUB -UP CONDUIT AT UTILITY POLE 20' ABOVE GRADE AND INSIDE ELECTRICAL BUILDING. 8, PROPOSED SPARE CONDUIT HANDHOLE, HANDHOLE SHALL BE UTILITY VAULT MODEL NO, 3030-LA OR EQUAL. CONTRACTOR SHALL PROVIDE EXCAVATION AND RESTORATION ORATION FOR INSTALLATION OF HANDHOLE PROVIDED AND INSTALLED BY CONTRACTOR, 9. CENTERLINE OF (12) 601 AND (10) 3" PVC ELECTRICAL CONDUITS, CONDUITS SHALL BE 36-INCHES DEEP AND STUBBED UP 36-INCHES ABO"VE GRADE, 3 FEET FROM EDGE OF DITCH. PROVIDE CORD PER SPECIFICATIONS AND CAP FOR FUTURE USE. DOCUMENT CONDUIT POSITION AND DEPTH ON AS -BUILT RECORDS, i 10. ELECTRICAL WORK IS REQUIRED AT THE CITYS HIGHLANDS RESERVOIR SITE. SEE DWG NO,'S C14 AND C15 FOR MORE INFORMATION. NOTE- PROPOSED LANDSCAPING NOT SHOWN, SEE DWG NO. C07 FOR PROPOSED SITE AND LANDSCAPING PLAN. SIGNED; 06,.'29,,,,07 .?&iCWAL SIGNED.' 061,291-107 z Uj -.Mir cn IN= w w W cl) 0 am 0 M t�. ".0 RH2 ENGINEERING, INC. http://www.rh2.com mailbox*rh2.com .800.720.8052 BELLINGHAM OFFICE 360.676.0836 454 West Horton Road BOTHELL OFFICE 425,951.5400 '2100 NE 195th Street, Suite 100 1:BAST WENATCHEE 0- 509.886.2900 .00 Simon Street, Suite 5 PORT ORCHARD OFF]i_i.. 360.876.7960 600 Kiltsap Street, Suite 101 SHOWN W 3 21416 I 0 1 2" 'PAWING 1'5 NOT TO SCAL:'-- I IF HAP IS NOT 2" LONG, 20 ENGINEER (.,MR C17 ,`Er:WEPl KAI KA SEP 14, 2009 10 REVISED TO CONFORM TO CONSTRUCTION RECORDS I DY KJS 06/08/09 .ILIENT PEN ADDENDUM / ISSUED FOR CONSTRUCTION BTE MM 10/091/0-7 105-049 )/34 -NAM, N, 0. REVISION h"Y RFEVIEW I Al' f HA_EN -D-CIV", J 6:t � P9,*P*_qFV FI Fr.Tglr.Al RITF P1 AV A r' f7- PROPOSED PRIMARY POWER SERVICE