Loading...
HomeMy WebLinkAboutWTR2703216.2CONSTRUCTION NOTES AND DETAILS 4.; 0 o� C) ° 0 o.E 3Q W -0 o_ L c ° v E 0 � — N m E I c 1 �I C 0 0 m IQ z< :D z Q� o } K Z � fn Z Q Y U W O � 2 Q a LO CD X Hp cn lv~i m ©ow" RAISE-1/2" WIDE BORDER 3/4" SQUARES SPACED - 3/4" AS INDICATED - HT. 1/8" 5/8" 1 I 2-7/8" 4" -7„®� 7-3/4" 8" 15" CAST IR❑N RING AND COVER PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTE: IN UNIMPROVED AREAS POUR 1'-0" THICK 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND RING AND COVER. IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. TESTING DETAIL II TAPPING TEE (MJxFL) TAPPING GATE VALVE (FL XMJ) TEMPORARY PLUG (MJ) WITH 2-INCH TAP AND 2-INCH BLOW -OFF ASSEMBLY CONCRETE BLOCKING 121 !� FIBER PACKII 45' (1/8) PLUG TO BE SEALED -�� IN SAME MANNER AS — — — — — MAIN SEWER J❑INTS. DATE REVISION I BY IAPPR D CONCRETE CLASS 3000 6 INCH OR 8 INCH CLEAN -OUT ADOPTED CITY OF RENTON AR Standard plans N C O_ LST DATE: 12/15/91 DWG. NAME: BW18B SP PAGE: B076 FINAL CONNECTION DETAIL MC'W n / WA rcp 1 1Alr �L`lA AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING FOR POLYPlGGING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF ONE BLIND FLANGE ON TOP WITH 2" TAP & 2" PLUG (MJ) AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS ONE BLIND FLANGE ON BOTTOM FINAL CONNECTION BY CITY FORCES ONE 2" TEMPORARY BLOW -OFF TEMPORARY BLOCK NOTES. 1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY - COATED STEEL. 2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. J. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4. WET -TAP SHALL BE DONE ONLY BY CITY -APPROVED CONTRACTORS CITY OF RENTON WATER LINE CONNECTION DETAIL TO SCALE CV/QTtA//' n , WI TCO , 1A,[• EXISTING D.I. WATER LINE FINAL CONNECTION DETAIL NEW D_ L WA TFR I IMF AFTER ALL CLEANING BY POLYP/G, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) do D.I. SPOOLS FINAL CONNECTION BY CITY FORCES TESTING DETAIL NEW D.I. WATER LINE REMOVE PLUG 12"X10" REDUCER (FLXMJ) VERTICAL CROSS (MJxFL) FOR POLYPIGGING 10" GATE VALVE (MJXFL) ONE BLIND FLANGE ON TOP WITH 2" TAP & 2" PLUG (MJ) TEMPORARY PLUG (MJ) WITH 2-INCH TAP ONE BLIND FLANGE ON BOTTOM AND 2-INCH BLOW -OFF ASSEMBLY ONE 2" TEMPORARY BLOW -OFF CONCRETE BLOCKING TEMPORARY BLOCK NOTES. 1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY - COATED STEEL. 2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. J. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4. WET -TAP SHALL BE DONE ONLY BY CITY -APPROVED CONTRACTORS CITY OF RENTON WATER LINE CONNECTION DETAIL TO SCALE —CUT -wx �c N1 vn lIr NDED MRAPPHOVAL ..r -DATE' >• v3z" /4P02P u CITY OF RENTON ®EF'ARTMBfVT ®F PUBLIC WORKS DESIGNED DRAWN STS - D3 CHECKED APPROVED DATE SCALE FILE NO. FIELD BOOK PAGE SHEET 8 OF 8 T �CI, DIRECTOR OF PUBLIC WORKS 32i�p,2