Loading...
HomeMy WebLinkAboutTRO4103219.3L 1%1.I� o r- z — 1 M \ 0 0 0 o w z F— C/) In a > a W V Z O CD af Q m Z O —� r .� o a o 0 � I_L z U) In C_ oo .- '0-- E Q �z - W � W 3 U '-�C 0)0 �E L E �, ;E O)N c I C Ql o Q) NOTES: All dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 4000PS1 concrete is allowed if box reinforcement consists of 6 X 6 — W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1/2" 10 gage divider plate complete with fasteners. Non —concrete Boxes may be submitted for approval. Evaluation will include an H-20 Load Test. JUNCTION BOX DIMENSION TABLE ITEM BOX TYPE TYPE 1 TYPE 2 ALTERNATE A ALTERNATE B A Box Outside length 22" 22" 33" B Box Outside Width 17" 17" 22 1 2" C Box Inside Length 18" 19" 28" D Box Inside Width 13" 14 17" E Lid Length 18" 18" 26 1 2" F Lid Width 13" 13" 17" G Box Depth 12" 12" 12" H Lid & Frame Depth 5 16" 5 16" 5 16" J Wall Thickness (Min.) 1 1 2" 1 1 2" 1 1 2" K Wire Reinforcement W-3 W-2.5 W-2.5 L Legend See Detail See Detail See Detail • • • ITEM MATERIALS Box 6000 PSI concrete See Notes Frame Diamond Plate Steel - A786 Lid Support 1 8"Min. Thick Steel C, L or T. - A36 Lid Diamond Plate Steel - A786 Anchors Steel Wire or Tee Plate Reinforcement ASTM A-82 Steel *GALVANIZED STEEL 1 FGFND DETAIL (Mark L) 1• Nom. t" Nam. SIGNALS LIGHTING TS—LT TELEMETRY Form Letters with 1/8" Weld Bead. Grind off Diamond Pattern before forming letters. DATE TSB TRAFFIC SIGNAL SYSTEM LEGEND LTA 1' Nom. 1" Nom. ILLUMINATION SYSTEM LEGEND PLAN VIEW T os ELEVATION VIEW MINI �� BELL ENDS J MIN. r MAIL ON CONDUIT 6" GRAVEL PAD COMPACTED TYPICAL JUNCTION BOX INSTALLATION DETAILS Ltd m TYPE 'I' BOX 0 TYPE 'II' BOX L Llxlx3/18. 1'Long HOOK DETAIL PLAN SYMBOLS (2 Hooke pr Lld) JUNCTION BOX DETAILS Y o ADOPTED CITY OF RENTON Standard plans N 0 LST DATE: 1 1 /89 DWG. NAME: JR-36 SP PAGE: JO16 DATE rnnvv r-11 1 WYE SPLICE 1n SPICE KIT x x x W z Z Y N 3 w a vv]i o o U o' n m Q —DIAMETER = 7/8" Q 0 m �-- 4-7/8 LOAD LINE 1 /4" FUSE 1 /4" mc�w 1/8"IN CUTTING z 00 FUSE KIT w a - Toes- toe -li z DA FUSE KIT & SPLICE KIT DETAILS Y O� ADOPTED CITY OF RENTON i Standard plans LST DATE: 11/5/96 DWG. NAME: JR-12 SP PAGE: JO1 3 L_ GHT NG STANDARD & JUNCTION BOX 7' o ov D ov ° ov D ° p0 4 A v 0 e o v 4 A o v O D o v pv `oD 0 0 0 AD ° 4 z D o PLAN VIEW D° C) °D� O O 0 4 0 0 Do D& A o p ° AD A O pv ° v w D D D VSTREET LIGHT POLE JUNCTION BOX SIDE VIEW ND U DUAL_ JUNCT ON BOX pv Oo 0 ° DoOv D D v ° p D o A OAv4 ° z D 4 = 0 O 4 ° o D °A O o �v v v 1' PLAN VIEW REVISION a 4 DEEP NOTE: CLASS 'B' CONCRETE TO BE USED IN CONSTRUCTION OF PAD 1' CONCRETE PAD DETAILS (' *JN� ADOPTED CITY OF RENTON oNAA Standard plans LST DATE: 10/30/96 DWG. NAME: JR-07 SP PAGE: J008 FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LUG CLEAR EPDXY SPLIA25"1 KITS ON ALL THRU" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE - PAD g°° illlf -1111=III -1111 8 GREEN ROUND WIRE ro 0111 2-(SIZED AS REQ'D) LIGHTING SYSTEM WIRES TO CONTACTOR — 5/8"x8' COPPER -CLAD GROUND ROD- -GROUND CLAMP -PVC CONDUIT SYSTEM CONCRETE FOUNDATION-� TO LUMINAIRE 1 /4" MINIMUM DRAIN HOLE -TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. IIII=illlf 11= IIII-1111 4' 3' OR SQ. DIA. TYPICAL LIGHTING UNDERGROUND SYSTEM Y O ADOPTED CITY OF RENTON NA Standard plans N O= LST DATE: 12/96 DWG. NAME: JR-06 SP PAGE: J007 i YNA �Q 30730 � 4 ReOISTERF� FSSJONAL ENQ\ EXPIRES 01/31/07 T-3?Ig03 RECOMMENDED FOR APPROVAL BY DATE BY DATE BY DATE HIE HERMAN TRAFFIC ENGINEERING 15324 Southeast 1 33rd Court, Renton, Washington 98059 425-277-1740 tel. 425-277-5718 fax hte@comcast.net SCANNED APR 2 2 206'5 T= 3 a'