Loading...
HomeMy WebLinkAboutSWP2703223.7JUTE MATTING EXISTING GRADE W Q z I— u Li 0 I— - � MIN BURY 6' 0 0 0 Q U i a V 0 Q a a 0 J U V) z 0 z w O 0 0 O O 0 i i 0 U z 0 F— z w Df L0 0 O a / 1 Q rl I - 0 N 0 a N 0 a V Q a a 2' BURY >50% OF LOG LENGTH 3 EARTH ANCHORS PER LOG, SEE NOTE 1 NOTES: ADAPTOR SKIRT, LOCATION REFERENCE POINT, TRIM TO WITHIN SEE TABLE DWG C2 3" — 5" OF GRATE UPSTREAM FACING LOG ON TOP EL 8.0 2' THICKNESS STREAMBED GRAVEL NATIVE MATERIAL 1. CHAIN LOGS WITH ROOTWADS TO EARTH ANCHOR 48" MIN INTO THE GROUND USING 5/16" DIA MIN GRADE 40 STEEL CHAIN MAKING TWO COMPLETE WRAPS AROUND LOG. SECURE W/SHACKLES, SCORE LOGS TO RECESS CHAIN. 2. SEE SPECIFICATIONS FOR ROOTWAD REQUIREMENTS. SECTION A LOG WITH ROOTWAD C2 (LOOKING DOWNSTREAM) NO SCALE 4" MAX CLR BETWEEN WALL OR OTHER POSTS 8'-0" MAX 1 1 /2" STD PIPE FOR RAIL AND POSTS LLJ Q 3/4"O PICKETS zCDoO� �w C�?4" CLR a o �O < CVO z zMz_LLI t T 11 ____4_j _ —1 I.1 '11 TOP OF PARAPET, 4 CONCRETE GUARDRAIL OR SIDEWALK DETAIL 3 STEEL PIPE HANDRAIL C4 NO SCALE 7' d a i 4 < 1 d 3' 0 0 p a °d 0 0 J d ° � JUNCTION BOX DETAIL 5 STREET LIGHT BASE C3 PLAN NO SCALE STREET LIGHT POLE GEOTEXTILE FABRIC RETRIEVAL STRAP OVERFLOW BYPASS FOR PEAK STORM VOLUMES SEDIMENT ACCUMULATION NOTES: 1. INSERT SHALL BE INSTALLED PRIOR TO CLEARING AND GRADING ACTIVITY, OR UPON PLACEMENT OF A NEW CATCH BASIN. 2. SEDIMENT SHALL BE REMOVED FROM THE UNIT WHEN IT BECOMES HALF FULL (12—INCHES FROM THE TOP OF THE SEDIMENT TO THE BOTTOM OF THE GRATE.) 3. SEDIMENT REMOVAL SHALL BE ACCOMPLISHED BY REMOVING THE INSERT, EMPTYING, AND RE—INSERTING IT INTO THE CATCH BASIN. DISPOSE OF SEDIMENT IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. DETAIL CATCH BASIN INSERT NO SCALE CENTER OF PARAPET OR CONCRETE GUARDRAIL =LOW ]ANDRAIL '4" DRAIN HOLE '2" CLEAR OF )NC PARAPET WALL OR CONCRETE GUARDRAIL SOCKET 1 /8" COVER PLATE TACK WELD @ 90' NOTES: 1. USE PIPE 3" STD x 0'-5". GALV AFTER FABRICATION. FILL SOCKET WITH NON— SHRINK GROUT AFTER INSTALLATION. 2. THIS DETAIL APPLIES TO INSTALLATION OF HANDRAIL IN CONCRETE GUARDRAIL OR PARAPET WALL. FOR INSTALLATION IN SIDEWALK, SEE STD DETAIL H024, DETAIL A. DETAIL 4 STEEL PIPE HANDRAIL PIPE SOCKET NO SCALE �ii F_ U ultA - — 0 ISSUE FOR BID NO. REVISION L AT WOOD POST 6' MAXIMUM SPACING TYPICAL DESIGN `B' JUNCTION BOX SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS 4" CONCRETE PAD #4@12EW@CTR #8 BARE COPPER GROUND WIRE 1 #8 GROUND WIRE 2 — LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REQ'D.) 5/8"x8' COPPER CLAD GROUND ROD SURVEYED: DH&A DESIGNED: LMG DRAWN: CAD — 2 — O CHECKED: MSG 8Y DATE APPR APPROVED: MSG DE7AL TEMPORARY SILT FENCE NO SCALE SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS S.E.C. OR EQUAL DETAIL STREET LIGHT BASE SECTION NO SCALE VERTICAL: NAVD 1988 }= CITY O F HORIZONTAL: NAD 1983/183/1991 �► RENTON CDTUM Planning/Building/Public Works Dept. TO LUMINAIRE 1 /AAAINIIAAI IAA 322307 TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. •ram 3" CLR 10 #5 VERT BARS EVENLY SPACED HK T&B #4 TIES @ 12" MAX SPACING ANCHOR BOLTS (4) 1 "X42" GALV A307 1 0 1 2 3 4 5 6 7 Scale Feet DATE: SW 34TH STREET 03/2/07 CULVERT REPLACEMENT PROJECT FIELDBOOK: CIVIL SECTIONS AND DETAILS PAGE: DRAWING NO: C5 0 cr CAI x It a� �cn C) — N o z� or W y� N