Loading...
HomeMy WebLinkAboutTED4003224.4RECORD DRAWING UTILITIES LIST OF ABBREVIATIONS LEGEND T oSEWER OTHER UTILITIES ABAN ABANDONED SYMBOL CITY OF RENTON GAS / POWER ACP ASPHALT CONCRETE PAVEMENT JOHN HOBSON 425-430-7279 PUGET SOUND ENERGY BVCE BEGIN VERTICAL CURVE ELEVATION EXISTING PROPOSED DESCRIPTION JOE JA I NGA 206-224-2120 BVCS BEGIN VERTICAL CURVE STATION , KING COUNTY 206-604-5662 CB CATCH BASIN BUS STOP EARL FISHER 206-296-6576 CENTERLINE COAL CREEK UTILITY DISTRICT QWEST CMP CORRUGATED METAL PIPE BOLLARD LARRY JONES 425-235-9200 MELANIE WHEELER 206-345-4055 CONIC CONCRETE ❑ ■ CATCH BASIN, TYPE 1 CORR CORRUGATED CATCH BASIN TYPE 2 WATER COMCAST COR CITY OF RENTON CABLE TV RISER JIM N I ES 2.53-288-7531 CITY OF RENTON CPEP CORRUGATED POLYETHYLENE PIPE T�; �- CABLE TV VAULT ABDOUL GAFOUR 425-430-7210 360 NETWORK D.I. DIA DUCTILE IRON DIAMETER =� CABLE TV VAULT KING COUNTY WILL DRONEN 206-920-0248 DROP DROP INLET DOWN GUY EARL FISHER 206-296-6576 DWY DRIVEWAY FIRE HYDRANT E EAST? FOUND TACK IN LEAD COAL CREEK UTILITY DISTRICT OTHER AGENCIES EL ELEVATION (j) GAS METER LARRY JONES 425-235-9200 ELEV ELEVATION - METRO - - GAS VALVE R I CHARD GARC I A 206-684-2732 EOP EDGE OF PAVEMENT - INVERT/CULVERT STORMWATER JIM KOST 206-684-2785 ESAL EQUIVALENT SINGLE AXLE LOAD EVCE END VERTICAL CURVE ELEVATION � IRRIGATION CONTROL BOX CITY OF RENTON FAX 206-684-2686 EVCS END VERTICAL CURVE STATION RONALD STRAKA 425-430-7248 EX EXISTING IRRIGATION CONTROL VALVE EXIST EXISTING -- ® MAILBOX HMA HOT MIX ASPHALT MONITOR WELL IE INVERT ELEVATION J O MONUMENT GENERAL NOTES: KCRS KING COUNTY ROAD STANDARD MANHOLE (TYPE UNKNOWN) LF LINEAL FEET j B POWER JUNCTION BOX LT LEFT POWER METER 1. FOR CATCH BASINS AND YARD DRAINS, STATION AND MH MANHOLE OFFSET REFER TO CENTER POINT OF GRATE.FOR MAX MAXIMUM POWER TRANSFORMER MANHOLES, STATION AND OFFSET REFER TO CENTER MIN MINIMUM _-' POWER VAULT POINT OF MANHOLE. NDCBU NEIGHBORHOOD DELIVERY AND COLLECTION BOX UNIT �' POWER RISER N NORTH = TELEPHONE RISER 2. CONTRACTOR SHALL COORDINATE WITH PUGET SOUND NE NORTHEAST 1. RAISED PAVEMENT MARKERS ENERGY FOR RELOCATING POWER LINES, REMOVING NW NORTHWEST LUMINAIRES, AND CONNECTING TO POWER VAULT. PI POINT OF HORIZONTAL INTERSECTION POWER LINES SHALL BE RELOCATED PRIOR TO CURB, PROP PROPOSED _Y_-" ROCK FACING GUTTER, AND SIDEWALK INSTALLATION. NTS NOT TO SCALE - ROCK WALL PVI POINT OF VERTICAL INTERSECTION 3. CONTRACTOR SHALL COORDINATE WITH THE TELEPHONE R RANGE (7) OO SANITARY SEWER MANHOLE COMPANY FOR ADJUSTING TELEPHONE RISERS AND RCP REINFORCED CONCRETE PIPE A0 SANITARY SEWER CLEANOUT MANHOLES TO GRADE. R/W RIGHT-OF-WAY M SHRUB ROW RIGHT-OF-WAY 4. CONTRACTOR SHALL COORDINATE WITH ENGINEER FOR RT RIGHT SIGN POST RELOCATION OF SIGNS OUTSIDE OF RIGHT-OF-WAY. S SLOPE -! SPRINKLER VALVE CONTRACTOR SHALL SUBMIT PLANS FOR RELOCATION SE SOUTHEAST STORM SEWER MANHOLE TO ENGINEER FOR APPROVAL. SEC SECTION - -- STORM DRAINAGE VAULT 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING SHLDR SSMH SHOULDER SANITARY SEWER MANHOLE STREET LIGHT ALL WORK IS DONE TO THE ALIGNMENTS, GRADES, ST STORM SEWER _ ^''-B STREET LIGHT CONTROL BOX AND ELEVATIONS CALLED FOR IN THE PLANS. STA STATION - TELEPHONE JUNCTION BOX CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION STD STANDARD TELEPHONE LE HONE MANHOLE SURVEYING. CONTRACTOR SHALL PROVIDE THE ENGINEER SW SOUTHWEST ❑TM TELEPHONE MARKER WITH AS -BUILT SURVEY DATA FOR ALL IMPROVEMENTS. TELE TELEPHONE ❑TF TELEPHONE RISER 6. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE T TV TOWNSHIP TELEVISION TELEPHONE VAULT WATER COMPANY FOR RELOCATING/ADJUSTING/RESETTING TYP TYPICAL [I TV RISER WATER METERS FIRE HYDRANTS, VALVE BOXES AND VALVE VC VERTICAL CURVE T TV JUNCTION BOX MANHOLES. SEE THIS SHEET FOR NAMES AND PHONE W WEST ❑TSCB TRAFFIC SIGNAL CONTROL BOX NUMBERS. WSDOT WASHINGTON STATE DEPARTMENT TRAFFIC SIGNAL LIGHT 7. ALL CONSTRUCTION MUST COMPLY 2004 STANDARD W.M. OF TRANSPORTATION WILLAMETTE MERIDIAN �- '� TRAFFIC SIGNAL POLE SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL WP WORK POINT WATER BLOWOFF VALVE CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. WATER MANHOLE 8. CONTRACTOR TO REPLACE OR ADJUST DISTURBED WATER METER MONUMENTS PER WSDOT STANDARD PLAN H-7. WATER SPIGOT m WATER VALVE 9. CONTRACTOR SHALL BE RESPONSIBLE FOR WOOD POLE TRAFFIC CONTROL PLANS. CONTRACTOR SHALL SUBMIT PLANS TO ENGINEER FOR APPROVAL. - TREE, CONIFEROUS 10. CONTRACTOR SHALL COORDINATE WITH QWEST FOR THE TREE, DECIDUOUS RELOCATING OR ADJUSTING OF CONDUIT AND PLACEMENT OF NEW/RELOCATED VAULTS. THIS WORK SHALL BE COMPLETED PRIOR TO CURB, GUTTER, AND SIDEWALK INSTALLATION. FED. AID NO. STPH-0900(21) a w 33301 9TH AVENUE SOUTH � RA'L V w w� CALL 48 HOURS � FEDERAL WAY, WASHINGTON SSIONAL FBEFORE YOU D I IG BERGER/ABAM 98003-2600 1-800-424-5555 ENGINEERS I N c. VOICE: (206)431-2300 EXPIRES 6/4/2011 FAX: (206)431-2250 Lasf Saved on Mon Jul 06 2009 at 10 58AM by AngeLmonta/vo Fi/e Name. 0.- jFederG1Way120041FAPWT-04-0.311CAD9Idwgs ICbannedizatlon IL—OLdwg Sco%.- 1 INFORMATION SHOWN ON RECORD DRAWINGS FOR LOCATIONS AND ELEVATIONS OF FEATURES WERE PROVIDED BY THE CITY OF RENTON AND/OR ITS CONSTRUCTION CONTRACTOR. BERGERABAM ASSUMES NO LIABILITY FOR THE ACCURACY OF THIS INFORMATION. SYMBOL EXISTING PROPOSED - - SD XXXXX T DESCRIPTION STORM DRAIN PIPE GUARD RAIL OUTERDUCT/CONDUIT AERIAL POWER LINE W/ TELEPHONE AND TV POWER LINE TELEPHONE LINE FENCE LINE BUILDING CONTOUR LINE (5' INTERVALS) CONTOUR LINE (1' INTERVALS) SS SANITARY SEWER GAS LINE TELECOMMUNICATIONS BANK WATER LINE UNDERGROUND POWER APPROX. RIGHT-OF-WAY STREET ADDRESS NUMBER (DUVALL AVE NE, UNLESS OTHERWISE NOTED) R=322404 SURVEYED: SCALE: DATE: As SHOWN HORIZONTAL• NAD 19V/11991 NE SUNSET BOULEVARD (SR 900)/ 6/03/09 DESIGNED: A• }� CITY OF DUVALL AVE NE INTERSECTION IMPROVEMENTS P`°°" DRAWN: _ RENTON ONE INCH DATUM I DRAWING NO: CHECKED: AT FULL -z"E Planning/Building/Public works Dept. LEGEND, ABBREVIATIONS AND GENERAL NOTES L 1 N 0. REVISION BY DATE AP P R IF NOT ONE INCH APPROVED: SCALE ACCORDINGLY SHEET: OF: 4 30 3a 4