Loading...
HomeMy WebLinkAboutTED4003227.1NE 114 SEC. 19, T WP. 23 N., R GE 5 E. w n O C) w J Ll1 w i Q z J U \ w D Of z O z W a I z z a z Q w a z J U z 0 U hi LEGEND R RIDGE LINE a1.50- PROPOSED SPOT ELEVATION 2' S0 EXISTING SPOT ELEVATION (NOT IN CON TRACT) 7 PROPOSED ELEVATION CONTOUR RE y0 POTENTIAL UNDERGROUND FACILITY OWNERS "ONE CALL" UTILITY NOTIFICATION CENTER 1-800-424-5555 I i INSTALL BYPASS SDMH I #3 OVER EXISTING 18" I i� /+ SD W/SOLID LID rr� / ! 7E=28.24 IE=23.18 (12" E) IE=23.10 (12" S) t 135 LONG x 40 WIDESTORM WATERETENTION AND I� I COMPENSATOR YSTORAGE VAULT __�A I I DETENTION VAULT ACCESS SDCO COVER W/ SOLLD LID (TYP.) _._ STORM MH x� TE=29.21 STORM MH l JJ ra &' TE=27.96 ` m � �oQ�wR"s • '� OTTOM VAULT=20.44 _.. BOTTOM VAULT=20.62 FF=28, 60 CB1 TYPE 1 APPLEBEES �� n fa CB 17 TYPE 1 CB #9 - TYPE I► 24LF 8 SD BYPA s1- -- -'-' _ TE=26. 47 FF= 28. 60 TE=27. 08 7E=26.80 .9 IE=24.36 (12" SW) ADS IE=24.94 (8" W) PVC IE-221.12 1.31 (18 SW) ADS 91.8VC 9 LF PVS N IE=21.17 (18" SE) ADS BYPASS SDMH #2 8" SD 0 0.39% TO VAULT l DIVIDE SOLID LID SDCO 6" PVC ROOF / 7E=26.72 -� DRAIN 0 2% MIN. _ IE=19.06 (18" NW) Ar S CB TYPES 1 RM MH TE= 6. 7 E 1 TE=6.87 V 0 MH 2Z 70 ►E=23.70 (12" NW) ADS IE=23.40 (12" N) ADS CS #8 TYPE'/1 (54") 8.43 BO VAULT=16.71 83°39 LF ADS N IE=23.64 (12" S) ADS IE=23.33 (12" SW) ADS 7E=26.53 TTOM VAUL -17.26 12" DI SD 0 0.46% 0 IE=22.05 (12" W) ADS 61.27 LF ADS N IE=22.55 (12" SW) ADS 29LF - 15" ? 1 8 F p5 12 SD 0 0.62% ss� 10 (DS 38.90 LF PVC � SID 0.5 ? DETENTION VAULT Z 7•6 � 4 � IE=22.(12" NE) ADS 8" SD 0 7.97% �o CONTROL STRUCTUR 2 S .__ � EXISTING 8" SEWER Sp q S REMOVE RIM=2Z72 ,j�2 TYPE 1 SOLID LI EXISTING SD. 4.1 7E 7" ORIFlCE=22.74 TE=27.44 __; .- 6018 137, 65 LF ADS N IE=23.97 (12" NE) ADS CB #6 TYPE 1 �'�J 1? Sp OS 15 SD 0 0.73X B 1 TYP 1 18" OUT=20.57 N IE=24.00 (12" SE) ADS TE=26.78 ® TE= .28 ORIFICE PLATE=18.59 IE=24.08 (8" SW) PVC IE=23.02 (12" NE) ADS IE 24.18 (8" NE) BOTTOM VAULT=16.56 / 35.47 LF PVC ti IE=23.99 12" SW ADS C TOP OF RISER=25.34 8" SD 0 0.46X IE-24.58 8 E PVC 3.30 LF AD N J , ►� INSTALL SDMH 12" SD 0 .58 DISCOUNT TIRE � � I � CB #3 TYPE 1 TYPE 11 O FF=28.60 TF=27.02 �• i 0VER EX. WELLS FARGO i CS 114 E 1 IE=24.24 (8" NE) PVC 7F SOLID28 4� FF=28. 60 z o�A TE-26.93 IE=22.1f (87EX)-`CB❑fl, 5 TYPE II N / IE=23.18 " W) S Q r 9�: REMOVE EX. CB & INSTALL 7E=2 51 / IE=23.10 1 E A P 20.85 LF - 2 CB TYPE il, 54"0 SURVEY UNABLE ( ) » �' SD 0 0.33% 7E=26.43 1 TO MEASURE � IE�2 7 229 (12" SW S 1� � P IE=18.22 (18" SW) ADS 208.31 LF ( ) ADS IE=17.80 (i8" NE) ADS 1 H ADS - 12" 82.84 LF ADS N -22 (12" NW) DS 89.40 SD 0 0.53% 12" SD CONNECT TO IE=1 Z85 (18" NW) ADS El0 0.65% EX. SDMH IE=18.25 (18" SE) ADS LF ADS - 12" IE=18.20 �I SD 00.41% ❑ ❑ ❑ ❑ ❑ ❑ ❑ INSTALL SDMH #7 TYPE II PVC PVC OVER EX. 1 90. 7 LF - 12" SD 0 0.49% SDMH TYP�11 66.24 LF ADS• 185 LF ADSSOLID LID12" SD 0 0.45% 12" SD 0 0.78X / TE=27.89 � SOLID UDC " CB #11 TYPE 1 TE=27.47 53.63 LF PVC N IE=21.77 (12 S) ADS 7E=26.94 CB #12 TYPE 1 " " IE=21.75 (12" E) ADS TE=28.95 -20.67 (12 S 8 SD 0 0.55% IE=23.53 (12 S) ADS IE=22.83 (12 SE) ADS IE 20.87 (12 W) S /SDMH TYPE 11 �• IE=21.77 (12" NW) ADS IE=23 86 (8" E) PVC " IE 20.82 (1 E) A S / SOLID D IE=23.08 12" N ADS IE=23.39 8 E PVC IE 2SMH (12 S) A TE=2Z89 T SSMH 5 /-- EX►ST. CB _ _ IE=19. 24 (12" N) ADS SCALE ' �Af9E-'Rlh ° CB 16 TYP IE=18.92 (18" SE) ADS 30 0 15 30 60 . _ TF=26.6 TE=2683� IE=21.53 (12" SW) ADS - - CB #15 TYPE I E=23>94(8" N) PVC (FEET ) CB #20 TE=26.81 TE=26.6± IE=23.47 (12" E) ADS 1 INCH = 30 ET LAKE AVE. S. IE=22.06 IE=23.65 (8" S) PVC 33 LF -8" SD 0 0.5% s f NOTE: RECORD DRAWING NOTE. 1) ALL TYPE II STORM MANHOLES ARE 48"0 UNLESS OTHERWISE NOTED. 2) ALL CBs ARE WSDOT TYPE I UNLESS OTHERWISE NOTED. -- --- - - - -- - 3) ALL CATCH BASIN LIDS SHALL BE LOCKING. . RECORD DRAWING PREPARED BY W&H PACIFIC BASED ON 4) ALL STORM DRAIN PIPES SHALL BE ADS UNLESS OTHERWISE NOTED. SURVEY BY W&H PACIFIC 5) FEMA FLOODPLAIN ELEVATION = 27.60 3350 M t V°ll P k EXPIRES: 08/28/07 on e 1 a ar way RECORD DRAWING HCS 02109107 JMTE SURVEYED: SCALE: Bothell, Washington 98021-8972 (425)951-4800 (425)951-4808 whpacific. com Planners • Engineers • Surveyors • Landscape Architects SCALE VERTICAL: NAVD C T Y O F HORIZONTAL: NAD 1983/183/1999 q DESIGNED:JD® �I DRAWN: CAW RENT 0 N ONE INCH DATUM CHECKED HCS AT FULL SCALE � Planning/Building/Public Works Dept, IF NOT ONE INCH N O. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY JWE JUN21207 Checked for Compliance to City Standards DATE: RENTON VILLAGE 02/12/07 FIELDBOOK: - RVA CENTER, LLC. PAGE: GRADING AND DRAINAGE DRAWING NO: SITE PLAN C4.0 SHEET: OF: 6 n A-NNNNLAA.1