Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WWP2703229.9
GENERAL AND SPECIAL NOTES TO CONSTRUCTION O PRE -CONSTRUCTION CONFERENCEi A PRE -CONSTRUCTION CONFERENCE AND TWENTY-FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING CONSTRUCTION, ® CITY OF RENTON TO PERFORM CONSTRUCTION INSPECTIONS AS REQUIRED PER CITY OF RENTON STANDARDS, © H-20 RATING: ALL STRUCTURES, MANHOLES, VAULTS, HANDHOLES, LIDS, COVERS, AND ACCESS HATC-IES INSTALLED ON THIS PROJECT SHALL BE H-20 TRAFFIC RATED, FORCE MAIN TO HAVE POSITIVE SLOPE AWAY FROM VALVE VAULT FOR FULL LENGTH OF FORCEMAIN, 0 WETWELL ISOLATION VALVE (10" MJ RESILIENT SEAT GATE VALVE WITH OPERATOR EXTENSION) TO WITHIN 3' ❑F GRADE, ® 6" SCH, 40 PVC WETWELL VENT, TERMINATE AT GRADE WITH 6' SS RISER AND SCREENED END GOOSENECK, SECURE 6" SS TO CONCRETE COLLAR, FINISH COLLAR 6" ABOVE GRADE, © YAGI ANTENNA ON 2 1/2' GALVANIZED PIPE MAST (12') WITH LADDER BRACKET, REDUCE TO 1" GALVANIZED FOR ANTENNA MOUNT, Q8 MCC ON 3'-9" x LENGTH AS REQUIRED x 1' CONCRETE PAD, #4 REINF, @ 12" EW, 4' ABOVE GRADE. ® 1 1/2 SUMP PUMP DISCHARGE LINE--(SCH, 40 PVC I,S, VAULT) WITH CHECK VALVE, UNION, & ISOLATION VALVE (SCH, 80 PVC O,S, VAULT), 0 4' DIA, GALV, PIPE BOLLARD - 3' BURY - 3' ABOVE GRADE. PAINT SAFETY YELLOW, Q AREA INSIDE ELECTRICAL HANDHOLES AND WETWELL REQUIRES EXPLOSION -PROOF ELECTRICAL WIRING AND EQUIPMENT PER ELECTRICAL CODE, ® ALL FLANGED CONNECTIONS IN WETWELL TO HAVE S,S. FASTENERS, ® ALL WIRE TO BE COPPER CONDUCTOR, INSULATION TO BE SUITABLE TO APPLICATION PER NEC, ® SUBMITTAL INFORMATION FOR EQUIPMENT SHALL BE PROVIDED TO THE CITY OF RENTON FOR THEIR REVIEW AND APPROVAL, ® DUCTILE IRON PIPE TO BE CLASS 52 WITH DUCTILE IRON FITTINGS, © PROVIDE PADLOCKS FOR HATCHES TO MATCH EXISTING CITY SECURITY SYSTEM, © PRESSURE TEST FORCEMAIN AT 150 PSI. PRESSURE TEST PIPE AND FITTINGS WITHIN VALVE VAULT .AND WETWELL. 2 1 FINAL REVIEW REVISION I LP 10-11-0 GW 1 REVIEW RE`nS10N I LP 19-17-041 GW 0 ORIGINAL 'SSUE LP 7-16-04 GW NO. REVISION BY DATE I APPR EXPIRES `% 2-6-013 GENERAL AND SPECIAL NOTES TO CONSTRUCTION (C❑NT'D) ITEM COATING PIPING 'IN WETWELL SSPC-SP-10 (WHITE BLAST), COLOR "GRAY -WHITE," 2 COATS TNEMEC SERIES 66 HI -BUILD EPDX❑LINE, 3-5 mil DFT (EACH COAT). INTERIOR OF WETWELL COAT WITH RAVEN 405 EPDXY WITH A-10 PRIMER, EXTERIOR OF WETWELL & VALVE VAULT TWO COATS SONNEBORNE HLM 5000, SEE SHEET 7 ITEM 30, PIPING 'IN VALVE VAULT SSPC-SP-6 (COMMERCIAL BLAST), COLOR "NEAR BLACK," 2 COATS TNEMEC SERIES 66 HI -BUILD EP❑XOLINE, 3-5 mil DFT (EACH COAT). INTERIOR OF VALVE VAULT ONE COAT SERIES 66, 4-6 mils DFT, 2 COATS 73 URETHANE, 3-5 mils. CITY OF RENTON TO DEVELOP A COLOR SCHEDULE FOR PAINTED ITEMS AFTER AWARD OF CONTRACT, 3 SETS ❑F OPERATION & MAINTENANCE MANUALS TO BE PROVIDED, ® STARTUP AND TRAINING OPERATION TO BE PERFORMED IN THE PRESENCE OF THE OWNER AND/OR THE OWNER'S REPRESENTATIVE, Q ONE SET OF AS -CONSTRUCTED DRAWINGS TO BE PROVIDED TO CITY ❑F RENTON ENGINEERING DEPARTMENT, 0 LIFT STATION STARTUP AND TESTING SHALL BE PERFORMED BY COINTRACTOR TO DEMONSTRATE FULL OPERATION OF FACILITY BEFORE ACCEPTANCE BY THE CITY OF RENTON, ® YARD LIGHT --SEE ELECTRICAL DRAWING, NTS "' '" CITY OF EVENDELL.LIFT STATION 1--5-27-OS s As-BUIL LP s-z7-os cw �NJNc' > Nrs `' CITY OF EVENDELLLIFT_STATION �s-27-05 RENTON "'1° 2 FINAL REVIEW REVISION LP 10-11--0 GW OE-Sn-rfWS.INC. RENTON 13815160TH AVE_SE 1 REVIEW REVISION LP 9-17-04 GW oEm_srsroas,wc. ''5_160TH_AVE _SE pe.r Planning/Building/Public Works Dept. R I---� 1 408 0 ORIGINAL ISSUE LP 7-i6-04 GW 9 9 P• 1 408 �.e"0f.■°`ae a: SITE PLAN NOTES > °ant s[is,INc.Y Plannin /Buiidin JPublk Works Ds t a s NO. REVISION BY DATE APPR Planning/Building/Public SITE _PLAN NOTES CONTINUED 4 1: NOTES l� DEDICATED RECEPTACLE FOR SUMP PUMP --LABEL "SUMP PUMP ONLY, r ALL ELECTRICAL EQUIPMENT WITHIN WETWELL AND HANDHOLES TO BE RATED EXPLOSION -PROOF CLASS I, DIV, L A UNDERGROUND: SCH 40 PVC CONDUIT (RGS TO 5' FROM STRUCTURES, WRAP HALF -LAPPED WITH 10mL TAPE,) LEGEND 21 HANDHOLE UTILITY VAULT MODEL NO, 233LA W/ COVER, O EXPLOSION -PROOF JUNCTION BOX ZL LIMIT SWITCH (2) TO ACTIVATE MCC INTERIOR FIGHT, SIEMENS MODEL No, 3SE03AR4, EYS SEAL © INTRUSION LIMIT SWITCH: SIEMENS MODEL NO, 3SE03AR1 (INTRUSION), • CONDUIT STUB -UP FLOOD ALARM SWITCH: MADISON CO, MODEL NO, 4YM31-1, MOUNT 2" ABOVE VAULT FLOOR, RECEPTACLE �$ CHECK VALVE LIMIT SWITCH (2): SIEMENS MODEL NO, 3SE03AR1, (PUMP FAIL) FAS FLOOD SWITCH 1/2 HP SUMP PUMP: PACO MODEL NO, PIP701C WITH LEVEL CONTROL FLOAT, FS FLOAT SWITCH EXPLOSION -PROOF LIGHT FIXTURE: APPLETON MODEL NO, AAU15N, 20OW LAMP, MS MOTOR STARTER SIEMENS MAG3100/5000 MAGNETIC FLOWMETER WITH DISPLAY UNIT MOUNTED ADJACENT -._O RTU, SP SUMP PUMP KPSI WETWELL LEVEL TRANSMITTER MODEL 720-140-00010-009 WITH UNSPLICED CABLE FM MAGNETIC FLOW METER TO HH2, CABLE HANGAR, AND VAPOR BARRIER WITH ANEROID BELLOWS MODEL 815, BELLOWS MOUNTED IN MCC. -,C� LIGHT #6 CU GIRD TO DIFM POLE -MOUNTED YARD LIGHT, GR 3/4" SPARE MCC 3/4" CONTROL CABINET /2 LS&2) - 1� _, , 1/2" PNL L - 4 #2 TO PSE 480V TRANSFORMER CU VALVE LS 2#12,1#126 VAULT 612-LA 4 #14, 1 #140 0 0 v3i c3 JB �FAS ©LS F SP C V i/z� LS CHVLS 1 GFI 1 SIGNAL CABLE HH2Z4\_\ c 3/4' 1„ RTU " 1" FS 3/4"PNL L �Y\ 7 #14, 1 #1415 4 #12 10 FS 2" HH1 A 1 #12G 1" 10 A 1" 3 #8, 1 #8G, 2 #14 SENSOR --EACH CONDUIT ��V mw ®� 144" WETWELL 2" SCH 80 PVC FOR PUMP CORDS N� CONDUIT DIAGRAM w � e EXPIRES `7-7-t-G 3 7-05 „ 1 408 AS -BUILT LP 5-27-05 GW . S5h7i' NTS ~'° awiEVENDELL CITY OF RENTON Planning/Building/Public Works Dept. LIFT _STATION 13815_160TH_AVE _SE I ELEC._PWR_&_SIGNAL_CONDUIT_DIAGRAM 2 FINAL REVIEW REVISION LP 10-11-0 GW i REVIEw REvsION LP 9-17-04 cw OE_5rMl ,S,lNc. I � r 0 ORIGINAL ISSUE LP 7-16-04 GW see a s5n�tslNc _wry„„—,,,r ,� I ms N0. REVISION BY DATE I APPR ------------ U w a o cn Z g o ttyao1 20 m N � 3 ~ ° J = M ZOO W W 1U w W IYm Tz o~ca tnZ a N �° Sri Z p Z _ 0 (0 UJ = Q U w w M (n 0 m O N a o w ,� 30 c tn� 6U tn� m v ci s wm z o_ o o ff, a° M oa ZO Z L`W w-J z,m oao z� o 80 Om U � Q zo a z V— z Z w p U w 0 0 0 ui Z p Z m� o �co a>op a�Gi m a� wwq Z~zo m0� mY 1T w old y3 oz o (n �- s go = ® I �0 3FZ j wW3 ww �u, t`o = wW g Y U ow a •-� oaz wg OZz O=ulm pU0 ��w m UV �m w Z wN Y Enm� i ! �w� Q o az woo � � mz I Zo �m 0I o J z o ao w o t- Uaz as sap°p�, U 5w �0 oo I Co oEn � as oo to Z= j w N w O OZ U 't OUO W Q� �� (nl6li O W p� UJY �-t �I` U� Cril wU O .00 1 mo ��� �w om� a a �z2 �8 �oz �0 3z wz� �N p O� cn ��� a aoa a�W 3o N om° �tz-00 ° zo Yam°} a� eo My ��wj iwz o o No t-S zeta H wr, ui w6z MO1 UAW a( d7 w �U x0 0 � I N0 Q ogcwo �o 0z: ova oLo �C aa070 'm Y aUJ z o ox �c~it U= ro ma �cno a mm °U�z m0 OL. aw0 aaL mInasa �Y (A05-i 20 a.E ym 2 I C fl© a s ® fl 0 fl e Q 4 ®®® Q x °F I '[-j n a f - o Z # O L1J J z Li 04 O to v � � I 0 Q Z j N M w z z� 3 ® �Sww z M 3 O atr0 O uj Y Z 11�auj : 3 ZZ rif > a p ° Z Q ° 4 c� O uj Q 01 ° Y O z M w aoN m z �a z o NF ct: L°coatas J 2 Z t coif Z (AW U a N W o N Q� i- O om z CL it Z Z N Z Y 04 ICI 61 J J w o m, Z�x oZ SO m: O m 0 U O O �O z po U LJ00 0 o a z ® o m N 0 � �oui a W z = �Q O �Y O 0 Q M N � I p o (n Z M l N 00 O °d O cn Lu a S031220cl !1- . � �CN-INc Nr5 °«15�. CITY OF RENTON Planning/Bulldin9/Public Works Dept. EVENDELLLIFT_STATION 13815_160TH_AVE_SE FURNAS_ OUTDOOR_ELECTRICAL_ENCLOSURE 5-27-05 ks-BUILT LP 5-27-05 Gw ' OENN_,HYMAS,Pwc. 2EVIEW REVISION LP 10-it-0 GW EW REVISION - - 'oEu._svSlEesdNc. ����,�„�o, � 1408 GNAL ISSUE LP 7-i6-04 GW a e REVISION BY DATE APPR r...n RH2�NgNifRINC.tNC. 10 1 z c U � o y A ti w N N 0